Diagnostic Accuracy of EndoFaster® and Narrow-Band Imaging Endoscopy in Patients with Impaired Gastric Acid Secretion: A Real-Time Prospective Study

Background. EndoFaster® analyzes gastric juice in real time during gastroscopy allowing the detection of hypo-achlorhydric conditions, like corpus atrophic gastritis. Narrow-band imaging (NBI) endoscopy allows to accurately detect and perform target biopsies in areas of intestinal metaplasia, a hist...

Full description

Saved in:
Bibliographic Details
Main Authors: M. Cazzato, G. Esposito, G. Galli, E. Pilozzi, E. Lahner, V. D. Corleto, A. Zullo, E. Di Giulio, B. Annibale
Format: Article
Language:English
Published: Wiley 2021-01-01
Series:Gastroenterology Research and Practice
Online Access:http://dx.doi.org/10.1155/2021/6616334
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832550969048563712
author M. Cazzato
G. Esposito
G. Galli
E. Pilozzi
E. Lahner
V. D. Corleto
A. Zullo
E. Di Giulio
B. Annibale
author_facet M. Cazzato
G. Esposito
G. Galli
E. Pilozzi
E. Lahner
V. D. Corleto
A. Zullo
E. Di Giulio
B. Annibale
author_sort M. Cazzato
collection DOAJ
description Background. EndoFaster® analyzes gastric juice in real time during gastroscopy allowing the detection of hypo-achlorhydric conditions, like corpus atrophic gastritis. Narrow-band imaging (NBI) endoscopy allows to accurately detect and perform target biopsies in areas of intestinal metaplasia, a histological change often associated to corpus atrophic gastritis. Aims. To compare the diagnostic accuracy of EndoFaster® with histological evaluation for corpus atrophic gastritis through high-resolution (HR) NBI targeted biopsies. Methods. Prospective study on consecutive adult patients undergoing gastroscopy between April and November 2018. Patients in therapy with proton pump inhibitors, previous gastric surgery, and/or known gastric neoplasia were excluded. At the beginning of gastroscopy, gastric juice was aspirated and analyzed by EndoFaster® in 15 seconds. Endoscopists were blinded to the report of EndoFaster®. Evaluation of gastric mucosa in HR-white light was firstly performed, then with HR-NBI allowing to perform targeted biopsies on areas suspected for intestinal metaplasia; otherwise, biopsies were performed according to the updated Sydney System protocol and sent for histopathological evaluation. Results. Overall, 124 patients were included [64% F; 56 (18-85) years]. Corpus atrophic gastritis was present in 41.9% of patients. EndoFaster® showed an accuracy for corpus atrophic gastritis diagnosis, compared to histopathological evaluation as gold standard, of 87.1% and a sensitivity, specificity, PPV, and NPV of 78.8%, 93.1%, 89.1%, and 85.9%, respectively. pH showed a positive correlation with the severity score of atrophy (r=0.67, 95% CI: 0.73-0.81, and p<0.0001). EndoFaster® allowed to diagnose corpus atrophic gastritis in 3.7% of patients negative to NBI (corpus atrophic gastritis without intestinal metaplasia). Conclusion. EndoFaster® seems a promising tool to diagnose corpus atrophic gastritis. The evaluation of hypo-achlorhydria during gastroscopy can address bioptic sampling in corpus atrophic gastritis patients without intestinal metaplasia.
format Article
id doaj-art-4c6650f85ee64b6085856681577e0994
institution Kabale University
issn 1687-6121
1687-630X
language English
publishDate 2021-01-01
publisher Wiley
record_format Article
series Gastroenterology Research and Practice
spelling doaj-art-4c6650f85ee64b6085856681577e09942025-02-03T06:05:16ZengWileyGastroenterology Research and Practice1687-61211687-630X2021-01-01202110.1155/2021/66163346616334Diagnostic Accuracy of EndoFaster® and Narrow-Band Imaging Endoscopy in Patients with Impaired Gastric Acid Secretion: A Real-Time Prospective StudyM. Cazzato0G. Esposito1G. Galli2E. Pilozzi3E. Lahner4V. D. Corleto5A. Zullo6E. Di Giulio7B. Annibale8Department of Medical-Surgical Sciences and Translational Medicine, Sant’Andrea Hospital, Sapienza University of Rome, ItalyDepartment of Medical-Surgical Sciences and Translational Medicine, Sant’Andrea Hospital, Sapienza University of Rome, ItalyDepartment of Medical-Surgical Sciences and Translational Medicine, Sant’Andrea Hospital, Sapienza University of Rome, ItalyDepartment of Pathology, Sant’Andrea Hospital, Sapienza University of Rome, ItalyDepartment of Medical-Surgical Sciences and Translational Medicine, Sant’Andrea Hospital, Sapienza University of Rome, ItalyDepartment of Medical-Surgical Sciences and Translational Medicine, Sant’Andrea Hospital, Sapienza University of Rome, ItalyGastroenterology and Digestive Endoscopy, “Nuovo Regina Margherita” Hospital, Rome, ItalyDepartment of Medical-Surgical Sciences and Translational Medicine, Sant’Andrea Hospital, Sapienza University of Rome, ItalyDepartment of Medical-Surgical Sciences and Translational Medicine, Sant’Andrea Hospital, Sapienza University of Rome, ItalyBackground. EndoFaster® analyzes gastric juice in real time during gastroscopy allowing the detection of hypo-achlorhydric conditions, like corpus atrophic gastritis. Narrow-band imaging (NBI) endoscopy allows to accurately detect and perform target biopsies in areas of intestinal metaplasia, a histological change often associated to corpus atrophic gastritis. Aims. To compare the diagnostic accuracy of EndoFaster® with histological evaluation for corpus atrophic gastritis through high-resolution (HR) NBI targeted biopsies. Methods. Prospective study on consecutive adult patients undergoing gastroscopy between April and November 2018. Patients in therapy with proton pump inhibitors, previous gastric surgery, and/or known gastric neoplasia were excluded. At the beginning of gastroscopy, gastric juice was aspirated and analyzed by EndoFaster® in 15 seconds. Endoscopists were blinded to the report of EndoFaster®. Evaluation of gastric mucosa in HR-white light was firstly performed, then with HR-NBI allowing to perform targeted biopsies on areas suspected for intestinal metaplasia; otherwise, biopsies were performed according to the updated Sydney System protocol and sent for histopathological evaluation. Results. Overall, 124 patients were included [64% F; 56 (18-85) years]. Corpus atrophic gastritis was present in 41.9% of patients. EndoFaster® showed an accuracy for corpus atrophic gastritis diagnosis, compared to histopathological evaluation as gold standard, of 87.1% and a sensitivity, specificity, PPV, and NPV of 78.8%, 93.1%, 89.1%, and 85.9%, respectively. pH showed a positive correlation with the severity score of atrophy (r=0.67, 95% CI: 0.73-0.81, and p<0.0001). EndoFaster® allowed to diagnose corpus atrophic gastritis in 3.7% of patients negative to NBI (corpus atrophic gastritis without intestinal metaplasia). Conclusion. EndoFaster® seems a promising tool to diagnose corpus atrophic gastritis. The evaluation of hypo-achlorhydria during gastroscopy can address bioptic sampling in corpus atrophic gastritis patients without intestinal metaplasia.http://dx.doi.org/10.1155/2021/6616334
spellingShingle M. Cazzato
G. Esposito
G. Galli
E. Pilozzi
E. Lahner
V. D. Corleto
A. Zullo
E. Di Giulio
B. Annibale
Diagnostic Accuracy of EndoFaster® and Narrow-Band Imaging Endoscopy in Patients with Impaired Gastric Acid Secretion: A Real-Time Prospective Study
Gastroenterology Research and Practice
title Diagnostic Accuracy of EndoFaster® and Narrow-Band Imaging Endoscopy in Patients with Impaired Gastric Acid Secretion: A Real-Time Prospective Study
title_full Diagnostic Accuracy of EndoFaster® and Narrow-Band Imaging Endoscopy in Patients with Impaired Gastric Acid Secretion: A Real-Time Prospective Study
title_fullStr Diagnostic Accuracy of EndoFaster® and Narrow-Band Imaging Endoscopy in Patients with Impaired Gastric Acid Secretion: A Real-Time Prospective Study
title_full_unstemmed Diagnostic Accuracy of EndoFaster® and Narrow-Band Imaging Endoscopy in Patients with Impaired Gastric Acid Secretion: A Real-Time Prospective Study
title_short Diagnostic Accuracy of EndoFaster® and Narrow-Band Imaging Endoscopy in Patients with Impaired Gastric Acid Secretion: A Real-Time Prospective Study
title_sort diagnostic accuracy of endofaster r and narrow band imaging endoscopy in patients with impaired gastric acid secretion a real time prospective study
url http://dx.doi.org/10.1155/2021/6616334
work_keys_str_mv AT mcazzato diagnosticaccuracyofendofasterandnarrowbandimagingendoscopyinpatientswithimpairedgastricacidsecretionarealtimeprospectivestudy
AT gesposito diagnosticaccuracyofendofasterandnarrowbandimagingendoscopyinpatientswithimpairedgastricacidsecretionarealtimeprospectivestudy
AT ggalli diagnosticaccuracyofendofasterandnarrowbandimagingendoscopyinpatientswithimpairedgastricacidsecretionarealtimeprospectivestudy
AT epilozzi diagnosticaccuracyofendofasterandnarrowbandimagingendoscopyinpatientswithimpairedgastricacidsecretionarealtimeprospectivestudy
AT elahner diagnosticaccuracyofendofasterandnarrowbandimagingendoscopyinpatientswithimpairedgastricacidsecretionarealtimeprospectivestudy
AT vdcorleto diagnosticaccuracyofendofasterandnarrowbandimagingendoscopyinpatientswithimpairedgastricacidsecretionarealtimeprospectivestudy
AT azullo diagnosticaccuracyofendofasterandnarrowbandimagingendoscopyinpatientswithimpairedgastricacidsecretionarealtimeprospectivestudy
AT edigiulio diagnosticaccuracyofendofasterandnarrowbandimagingendoscopyinpatientswithimpairedgastricacidsecretionarealtimeprospectivestudy
AT bannibale diagnosticaccuracyofendofasterandnarrowbandimagingendoscopyinpatientswithimpairedgastricacidsecretionarealtimeprospectivestudy