Fully Automated Radioligand Binding Filtration Assay for Membrane-Bound Receptors

Here we describe a fully automated, hands-free radioligand filtration binding assay for dopamine D3 receptors. Three separate instruments were linked in tandem to perform the following operations: The Genmate and Genesis were linked to perform liquid handling, incubation, and the scheduling operatio...

Full description

Saved in:
Bibliographic Details
Main Authors: A. Shrikhande, C. Courtney, D. Smith, M. Melch, M. McConkey, J. Bergeron, Stephen K-F. Wong
Format: Article
Language:English
Published: Taylor & Francis Group 2002-10-01
Series:BioTechniques
Online Access:https://www.future-science.com/doi/10.2144/02334pf01
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850152054403629056
author A. Shrikhande
C. Courtney
D. Smith
M. Melch
M. McConkey
J. Bergeron
Stephen K-F. Wong
author_facet A. Shrikhande
C. Courtney
D. Smith
M. Melch
M. McConkey
J. Bergeron
Stephen K-F. Wong
author_sort A. Shrikhande
collection DOAJ
description Here we describe a fully automated, hands-free radioligand filtration binding assay for dopamine D3 receptors. Three separate instruments were linked in tandem to perform the following operations: The Genmate and Genesis were linked to perform liquid handling, incubation, and the scheduling operations, while an automated harvester was used to perform rapid filtration. To minimize carryover of compounds, disposable tips were used for diluting and dispensing the compounds. A custom-designed tip holder was used to handle loading and pipetting by the Genmate 96-well pipettor. The assay for 84 compounds with six concentrations that spans six logs can be completed within 4 h. The reproducibility of the individual data point (cv < 10% between duplicates) and Ki (cv < 20%) is superior to that determined by manual procedures. Ki values of various dopamine ligands determined by the hands-free procedure are similar to published values. This technology reduces hands-on time (at least 70%), minimizes exposure to radioligands (up to 95%), and improves the reproducibility of results. The technology is applicable for high-throughput screening and rapid determination of structure-activity relationship of compounds for many other membrane-bound receptors.
format Article
id doaj-art-4bf5e9699c7f4b37a0352568f20648dc
institution OA Journals
issn 0736-6205
1940-9818
language English
publishDate 2002-10-01
publisher Taylor & Francis Group
record_format Article
series BioTechniques
spelling doaj-art-4bf5e9699c7f4b37a0352568f20648dc2025-08-20T02:26:05ZengTaylor & Francis GroupBioTechniques0736-62051940-98182002-10-0133493293710.2144/02334pf01Fully Automated Radioligand Binding Filtration Assay for Membrane-Bound ReceptorsA. Shrikhande0C. Courtney1D. Smith2M. Melch3M. McConkey4J. Bergeron5Stephen K-F. Wong61Pfizer Global Research and Development, Pfizer, Groton, CT, USA1Pfizer Global Research and Development, Pfizer, Groton, CT, USA1Pfizer Global Research and Development, Pfizer, Groton, CT, USA1Pfizer Global Research and Development, Pfizer, Groton, CT, USA1Pfizer Global Research and Development, Pfizer, Groton, CT, USA1Pfizer Global Research and Development, Pfizer, Groton, CT, USA1Pfizer Global Research and Development, Pfizer, Groton, CT, USAHere we describe a fully automated, hands-free radioligand filtration binding assay for dopamine D3 receptors. Three separate instruments were linked in tandem to perform the following operations: The Genmate and Genesis were linked to perform liquid handling, incubation, and the scheduling operations, while an automated harvester was used to perform rapid filtration. To minimize carryover of compounds, disposable tips were used for diluting and dispensing the compounds. A custom-designed tip holder was used to handle loading and pipetting by the Genmate 96-well pipettor. The assay for 84 compounds with six concentrations that spans six logs can be completed within 4 h. The reproducibility of the individual data point (cv < 10% between duplicates) and Ki (cv < 20%) is superior to that determined by manual procedures. Ki values of various dopamine ligands determined by the hands-free procedure are similar to published values. This technology reduces hands-on time (at least 70%), minimizes exposure to radioligands (up to 95%), and improves the reproducibility of results. The technology is applicable for high-throughput screening and rapid determination of structure-activity relationship of compounds for many other membrane-bound receptors.https://www.future-science.com/doi/10.2144/02334pf01
spellingShingle A. Shrikhande
C. Courtney
D. Smith
M. Melch
M. McConkey
J. Bergeron
Stephen K-F. Wong
Fully Automated Radioligand Binding Filtration Assay for Membrane-Bound Receptors
BioTechniques
title Fully Automated Radioligand Binding Filtration Assay for Membrane-Bound Receptors
title_full Fully Automated Radioligand Binding Filtration Assay for Membrane-Bound Receptors
title_fullStr Fully Automated Radioligand Binding Filtration Assay for Membrane-Bound Receptors
title_full_unstemmed Fully Automated Radioligand Binding Filtration Assay for Membrane-Bound Receptors
title_short Fully Automated Radioligand Binding Filtration Assay for Membrane-Bound Receptors
title_sort fully automated radioligand binding filtration assay for membrane bound receptors
url https://www.future-science.com/doi/10.2144/02334pf01
work_keys_str_mv AT ashrikhande fullyautomatedradioligandbindingfiltrationassayformembraneboundreceptors
AT ccourtney fullyautomatedradioligandbindingfiltrationassayformembraneboundreceptors
AT dsmith fullyautomatedradioligandbindingfiltrationassayformembraneboundreceptors
AT mmelch fullyautomatedradioligandbindingfiltrationassayformembraneboundreceptors
AT mmcconkey fullyautomatedradioligandbindingfiltrationassayformembraneboundreceptors
AT jbergeron fullyautomatedradioligandbindingfiltrationassayformembraneboundreceptors
AT stephenkfwong fullyautomatedradioligandbindingfiltrationassayformembraneboundreceptors