Study and Application on Primary Frequency Modulation Capability by Using Comprehensive Energy Storage of a 660 MW Water Heat and Power Cogeneration Supercritical Unit
In this paper, the design parameters such as the heat balance diagram of a 660 MW water heat and power cogeneration supercritical unit are used to conduct the theoretical study based on the quantitative analysis of the primary frequency modulation capacity of condensate throttling and heat extractio...
Saved in:
| Main Authors: | , , |
|---|---|
| Format: | Article |
| Language: | zho |
| Published: |
State Grid Energy Research Institute
2020-01-01
|
| Series: | Zhongguo dianli |
| Subjects: | |
| Online Access: | https://www.electricpower.com.cn/CN/10.11930/j.issn.1004-9649.201904094 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1850053145155076096 |
|---|---|
| author | Shunqing CHEN Jianping YAN Yusheng ZHANG |
| author_facet | Shunqing CHEN Jianping YAN Yusheng ZHANG |
| author_sort | Shunqing CHEN |
| collection | DOAJ |
| description | In this paper, the design parameters such as the heat balance diagram of a 660 MW water heat and power cogeneration supercritical unit are used to conduct the theoretical study based on the quantitative analysis of the primary frequency modulation capacity of condensate throttling and heat extraction throttling of the unit. Then the theoretical gain and rule of each throttling change corresponding to the unit power change are obtained respectively under the working conditions of 100%, 75% and 50% THA. Within the scope of safety control, the experimental study on primary frequency modulation capability in terms of comprehensive energy storage of the unit is carried out, hence the actual gain and rule of each throttling change corresponding to the unit power change as well as the actual capacity of primary frequency modulation in terms of comprehensive energy storage are calculated under the working conditions of 350 MW, 450 MW and 600 MW respectively. Based on the original primary frequency modulation control logic of the unit and in combination with the experimental results, a comprehensive energy storage module is developed for the primary frequency modulation of the unit. The simulation application demonstrates satisfactory results. The primary frequency modulation capability has met the related requirements and therefore indirectly improved the economic efficiency of the unit. |
| format | Article |
| id | doaj-art-4bb3f8a4cefe48ceb21ac3922cc84d3c |
| institution | DOAJ |
| issn | 1004-9649 |
| language | zho |
| publishDate | 2020-01-01 |
| publisher | State Grid Energy Research Institute |
| record_format | Article |
| series | Zhongguo dianli |
| spelling | doaj-art-4bb3f8a4cefe48ceb21ac3922cc84d3c2025-08-20T02:52:37ZzhoState Grid Energy Research InstituteZhongguo dianli1004-96492020-01-0153117718410.11930/j.issn.1004-9649.201904094zgdl-53-1-chenshunqingStudy and Application on Primary Frequency Modulation Capability by Using Comprehensive Energy Storage of a 660 MW Water Heat and Power Cogeneration Supercritical UnitShunqing CHEN0Jianping YAN1Yusheng ZHANG2Hebei Guohua Cangdong Power Generation Co., Ltd., Cangzhou 061003, ChinaHebei Guohua Cangdong Power Generation Co., Ltd., Cangzhou 061003, ChinaHebei Guohua Cangdong Power Generation Co., Ltd., Cangzhou 061003, ChinaIn this paper, the design parameters such as the heat balance diagram of a 660 MW water heat and power cogeneration supercritical unit are used to conduct the theoretical study based on the quantitative analysis of the primary frequency modulation capacity of condensate throttling and heat extraction throttling of the unit. Then the theoretical gain and rule of each throttling change corresponding to the unit power change are obtained respectively under the working conditions of 100%, 75% and 50% THA. Within the scope of safety control, the experimental study on primary frequency modulation capability in terms of comprehensive energy storage of the unit is carried out, hence the actual gain and rule of each throttling change corresponding to the unit power change as well as the actual capacity of primary frequency modulation in terms of comprehensive energy storage are calculated under the working conditions of 350 MW, 450 MW and 600 MW respectively. Based on the original primary frequency modulation control logic of the unit and in combination with the experimental results, a comprehensive energy storage module is developed for the primary frequency modulation of the unit. The simulation application demonstrates satisfactory results. The primary frequency modulation capability has met the related requirements and therefore indirectly improved the economic efficiency of the unit.https://www.electricpower.com.cn/CN/10.11930/j.issn.1004-9649.201904094water heat and power cogenerationsupercritical unitcomprehensive energy storageprimary frequency modulation capacitytheoretical studyexperimental studyapplication |
| spellingShingle | Shunqing CHEN Jianping YAN Yusheng ZHANG Study and Application on Primary Frequency Modulation Capability by Using Comprehensive Energy Storage of a 660 MW Water Heat and Power Cogeneration Supercritical Unit Zhongguo dianli water heat and power cogeneration supercritical unit comprehensive energy storage primary frequency modulation capacity theoretical study experimental study application |
| title | Study and Application on Primary Frequency Modulation Capability by Using Comprehensive Energy Storage of a 660 MW Water Heat and Power Cogeneration Supercritical Unit |
| title_full | Study and Application on Primary Frequency Modulation Capability by Using Comprehensive Energy Storage of a 660 MW Water Heat and Power Cogeneration Supercritical Unit |
| title_fullStr | Study and Application on Primary Frequency Modulation Capability by Using Comprehensive Energy Storage of a 660 MW Water Heat and Power Cogeneration Supercritical Unit |
| title_full_unstemmed | Study and Application on Primary Frequency Modulation Capability by Using Comprehensive Energy Storage of a 660 MW Water Heat and Power Cogeneration Supercritical Unit |
| title_short | Study and Application on Primary Frequency Modulation Capability by Using Comprehensive Energy Storage of a 660 MW Water Heat and Power Cogeneration Supercritical Unit |
| title_sort | study and application on primary frequency modulation capability by using comprehensive energy storage of a 660 mw water heat and power cogeneration supercritical unit |
| topic | water heat and power cogeneration supercritical unit comprehensive energy storage primary frequency modulation capacity theoretical study experimental study application |
| url | https://www.electricpower.com.cn/CN/10.11930/j.issn.1004-9649.201904094 |
| work_keys_str_mv | AT shunqingchen studyandapplicationonprimaryfrequencymodulationcapabilitybyusingcomprehensiveenergystorageofa660mwwaterheatandpowercogenerationsupercriticalunit AT jianpingyan studyandapplicationonprimaryfrequencymodulationcapabilitybyusingcomprehensiveenergystorageofa660mwwaterheatandpowercogenerationsupercriticalunit AT yushengzhang studyandapplicationonprimaryfrequencymodulationcapabilitybyusingcomprehensiveenergystorageofa660mwwaterheatandpowercogenerationsupercriticalunit |