An Advanced Partial Discharge Recognition Strategy of Power Cable

Detection and localization of partial discharge are very important in condition monitoring of power cables, so it is necessary to build an accurate recognizer to recognize the discharge types. In this paper, firstly, a power cable model based on FDTD simulation is built to get the typical discharge...

Full description

Saved in:
Bibliographic Details
Main Authors: Xiaotian Bi, Ang Ren, Simeng Li, Mingming Han, Qingquan Li
Format: Article
Language:English
Published: Wiley 2015-01-01
Series:Journal of Electrical and Computer Engineering
Online Access:http://dx.doi.org/10.1155/2015/174538
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Detection and localization of partial discharge are very important in condition monitoring of power cables, so it is necessary to build an accurate recognizer to recognize the discharge types. In this paper, firstly, a power cable model based on FDTD simulation is built to get the typical discharge signals as training samples. Secondly, because the extraction of discharge signal features is crucial, fractal characteristics of the training samples are extracted and inputted into the recognizer. To make the results more accurate, multi-SVM recognizer made up of six Support Vector Machines (SVM) is proposed in this paper. The result of the multi-SVM recognizer is determined by the vote of the six SVM. Finally, the BP neural networks and ELM are compared with multi-SVM. The accuracy comparison shows that the multi-SVM recognizer has the best accuracy and stability, and it can recognize the discharge type efficiently.
ISSN:2090-0147
2090-0155