Manufacturing of Physical Phantom and Evaluation of a Software for Automated and Remote Quality Control in Mammography Using a Retrofit DR System
Mammography is crucial for the early detection of breast cancer, requiring periodic quality controls to ensure that images and patient exposure doses comply with regulatory limits. This study addresses the challenges involved in conducting quality control, such as the lack of qualified personnel and...
Saved in:
| Main Authors: | , , , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Brazilian Radiation Protection Society (Sociedade Brasileira de Proteção Radiológica, SBPR)
2025-05-01
|
| Series: | Brazilian Journal of Radiation Sciences |
| Subjects: | |
| Online Access: | https://bjrs.org.br/revista/index.php/REVISTA/article/view/2528 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1849429846391783424 |
|---|---|
| author | Laila Fernanda Moreira de Almeida Camila Engler Peterson Lima Squair Maria do Socorro Nogueira |
| author_facet | Laila Fernanda Moreira de Almeida Camila Engler Peterson Lima Squair Maria do Socorro Nogueira |
| author_sort | Laila Fernanda Moreira de Almeida |
| collection | DOAJ |
| description | Mammography is crucial for the early detection of breast cancer, requiring periodic quality controls to ensure that images and patient exposure doses comply with regulatory limits. This study addresses the challenges involved in conducting quality control, such as the lack of qualified personnel and the subjectivity of daily evaluations with phantoms. Additionally, the research proposes the incorporation of automated and remote quality control tools. In this context, a simple phantom was developed by the IAEA using materials such as copper, acrylic, and aluminum, to be used with the Automated Tool for Image Analysis (ATIA) software. This software performs automatic image analyses, extracting data from the DICOM header and exporting it to a CSV file for analysis in Excel® spreadsheets. The objectives of this work were: (a) to manufacture the phantom according to the standard model from the IAEA Human Health Series No. 39 publication; (b) to apply the ATIA software in the daily monitoring of a mammography unit and the digital radiography (DR) image receptor retrofitted to an analog mammography unit at the Laboratory of Radioprotection Applied to Mammography (LARAM) of CDTN; (c) to evaluate and compare the responses obtained between the automated ATIA software and the manual IMAGEJ software. The results demonstrated the stability and consistency of the mammography system in metrics such as SDNR and SNR, essential for ensuring image quality. However, variabilities in horizontal and vertical MTF at lower spatial frequencies indicate discrepancies in resolving fine details. The detectability index (D') stood out for its high consistency, indicating the reliability of the mammography system in detecting small details. Thus, it can be inferred that significant differences between quality control software in various metrics highlight the importance of careful software selection to meet specific mammographic evaluation needs.
|
| format | Article |
| id | doaj-art-4adf5f698ad94ac28af2aa99ccc170bd |
| institution | Kabale University |
| issn | 2319-0612 |
| language | English |
| publishDate | 2025-05-01 |
| publisher | Brazilian Radiation Protection Society (Sociedade Brasileira de Proteção Radiológica, SBPR) |
| record_format | Article |
| series | Brazilian Journal of Radiation Sciences |
| spelling | doaj-art-4adf5f698ad94ac28af2aa99ccc170bd2025-08-20T03:28:13ZengBrazilian Radiation Protection Society (Sociedade Brasileira de Proteção Radiológica, SBPR)Brazilian Journal of Radiation Sciences2319-06122025-05-01124A (Suppl.)10.15392/2319-0612.2024.25282153Manufacturing of Physical Phantom and Evaluation of a Software for Automated and Remote Quality Control in Mammography Using a Retrofit DR SystemLaila Fernanda Moreira de Almeida0https://orcid.org/0009-0007-1494-6381Camila Engler1Peterson Lima Squair2Maria do Socorro Nogueira3Centro de Desenvolvimento da Tecnologia NuclearCentro de Desenvolvimento da Tecnologia NuclearCentro de Desenvolvimento da Tecnologia NuclearCentro de Desenvolvimento da Tecnologia NuclearMammography is crucial for the early detection of breast cancer, requiring periodic quality controls to ensure that images and patient exposure doses comply with regulatory limits. This study addresses the challenges involved in conducting quality control, such as the lack of qualified personnel and the subjectivity of daily evaluations with phantoms. Additionally, the research proposes the incorporation of automated and remote quality control tools. In this context, a simple phantom was developed by the IAEA using materials such as copper, acrylic, and aluminum, to be used with the Automated Tool for Image Analysis (ATIA) software. This software performs automatic image analyses, extracting data from the DICOM header and exporting it to a CSV file for analysis in Excel® spreadsheets. The objectives of this work were: (a) to manufacture the phantom according to the standard model from the IAEA Human Health Series No. 39 publication; (b) to apply the ATIA software in the daily monitoring of a mammography unit and the digital radiography (DR) image receptor retrofitted to an analog mammography unit at the Laboratory of Radioprotection Applied to Mammography (LARAM) of CDTN; (c) to evaluate and compare the responses obtained between the automated ATIA software and the manual IMAGEJ software. The results demonstrated the stability and consistency of the mammography system in metrics such as SDNR and SNR, essential for ensuring image quality. However, variabilities in horizontal and vertical MTF at lower spatial frequencies indicate discrepancies in resolving fine details. The detectability index (D') stood out for its high consistency, indicating the reliability of the mammography system in detecting small details. Thus, it can be inferred that significant differences between quality control software in various metrics highlight the importance of careful software selection to meet specific mammographic evaluation needs. https://bjrs.org.br/revista/index.php/REVISTA/article/view/2528MammographyQuality Control Automation |
| spellingShingle | Laila Fernanda Moreira de Almeida Camila Engler Peterson Lima Squair Maria do Socorro Nogueira Manufacturing of Physical Phantom and Evaluation of a Software for Automated and Remote Quality Control in Mammography Using a Retrofit DR System Brazilian Journal of Radiation Sciences Mammography Quality Control Automation |
| title | Manufacturing of Physical Phantom and Evaluation of a Software for Automated and Remote Quality Control in Mammography Using a Retrofit DR System |
| title_full | Manufacturing of Physical Phantom and Evaluation of a Software for Automated and Remote Quality Control in Mammography Using a Retrofit DR System |
| title_fullStr | Manufacturing of Physical Phantom and Evaluation of a Software for Automated and Remote Quality Control in Mammography Using a Retrofit DR System |
| title_full_unstemmed | Manufacturing of Physical Phantom and Evaluation of a Software for Automated and Remote Quality Control in Mammography Using a Retrofit DR System |
| title_short | Manufacturing of Physical Phantom and Evaluation of a Software for Automated and Remote Quality Control in Mammography Using a Retrofit DR System |
| title_sort | manufacturing of physical phantom and evaluation of a software for automated and remote quality control in mammography using a retrofit dr system |
| topic | Mammography Quality Control Automation |
| url | https://bjrs.org.br/revista/index.php/REVISTA/article/view/2528 |
| work_keys_str_mv | AT lailafernandamoreiradealmeida manufacturingofphysicalphantomandevaluationofasoftwareforautomatedandremotequalitycontrolinmammographyusingaretrofitdrsystem AT camilaengler manufacturingofphysicalphantomandevaluationofasoftwareforautomatedandremotequalitycontrolinmammographyusingaretrofitdrsystem AT petersonlimasquair manufacturingofphysicalphantomandevaluationofasoftwareforautomatedandremotequalitycontrolinmammographyusingaretrofitdrsystem AT mariadosocorronogueira manufacturingofphysicalphantomandevaluationofasoftwareforautomatedandremotequalitycontrolinmammographyusingaretrofitdrsystem |