Single-Phase Grid-Connected Inverter With Predictive Control Cost Function for Leakage Current Mitigation and FAS Model

Leakage current is one of the main issues for transformerless grid-connected photovoltaic inverters, and its reduction is a primary focus of various studies reported in the literature. This article proposes and validates a finite control set model predictive controller with a novel cost function to...

Full description

Saved in:
Bibliographic Details
Main Authors: Cesar Limones, Nimrod Vazquez, Ricardo Femat, Leonel Estrada, Jeziel Vazquez, Claudia Hernandez, Angel de Castro, Joaquin Vaquero
Format: Article
Language:English
Published: IEEE 2025-01-01
Series:IEEE Open Journal of the Industrial Electronics Society
Subjects:
Online Access:https://ieeexplore.ieee.org/document/10982184/
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849321494912434176
author Cesar Limones
Nimrod Vazquez
Ricardo Femat
Leonel Estrada
Jeziel Vazquez
Claudia Hernandez
Angel de Castro
Joaquin Vaquero
author_facet Cesar Limones
Nimrod Vazquez
Ricardo Femat
Leonel Estrada
Jeziel Vazquez
Claudia Hernandez
Angel de Castro
Joaquin Vaquero
author_sort Cesar Limones
collection DOAJ
description Leakage current is one of the main issues for transformerless grid-connected photovoltaic inverters, and its reduction is a primary focus of various studies reported in the literature. This article proposes and validates a finite control set model predictive controller with a novel cost function to mitigate leakage current in a single-phase full-bridge (FB) grid-connected inverter with an <italic>LCL</italic> filter, making no modifications to the traditional FB topology and without adding any extra components. Furthermore, mathematical modeling is based on the fully actuated system model, allowing a reduction in the number of variables sensed during implementation, resulting in only grid current and voltage being measured.
format Article
id doaj-art-4ad732fa04b7454fbb3ed61069e8f552
institution Kabale University
issn 2644-1284
language English
publishDate 2025-01-01
publisher IEEE
record_format Article
series IEEE Open Journal of the Industrial Electronics Society
spelling doaj-art-4ad732fa04b7454fbb3ed61069e8f5522025-08-20T03:49:45ZengIEEEIEEE Open Journal of the Industrial Electronics Society2644-12842025-01-01676477410.1109/OJIES.2025.356658210982184Single-Phase Grid-Connected Inverter With Predictive Control Cost Function for Leakage Current Mitigation and FAS ModelCesar Limones0Nimrod Vazquez1https://orcid.org/0000-0002-6363-513XRicardo Femat2Leonel Estrada3https://orcid.org/0000-0002-4542-3598Jeziel Vazquez4https://orcid.org/0000-0001-5093-5777Claudia Hernandez5Angel de Castro6https://orcid.org/0000-0003-4357-7857Joaquin Vaquero7https://orcid.org/0000-0002-6976-0564Department of Electronics Engineering, TecNM / Instituto Tecnol&#x00F3;gico de Celaya, Celaya, M&#x00E9;xicoDepartment of Electronics Engineering, TecNM / Instituto Tecnol&#x00F3;gico de Celaya, Celaya, M&#x00E9;xicoDynamical System Department, of IPICyT, San Luis Potos&#x00ED;, San Luis Potos&#x00ED;, MexicoDepartment of Electronics Engineering, TecNM / Instituto Tecnol&#x00F3;gico de Celaya, Celaya, M&#x00E9;xicoMechatronics Department of the Polytechnic University of Quer&#x00E9;taro, Quer&#x00E9;taro, MexicoDepartment of Electronics Engineering, TecNM / Instituto Tecnol&#x00F3;gico de Celaya, Celaya, M&#x00E9;xicoElectronics and Communications Technology Department, Autonomous University of Madrid, Madrid, SpainElectronics Technology Area, Rey Juan Carlos University, Mostoles, SpainLeakage current is one of the main issues for transformerless grid-connected photovoltaic inverters, and its reduction is a primary focus of various studies reported in the literature. This article proposes and validates a finite control set model predictive controller with a novel cost function to mitigate leakage current in a single-phase full-bridge (FB) grid-connected inverter with an <italic>LCL</italic> filter, making no modifications to the traditional FB topology and without adding any extra components. Furthermore, mathematical modeling is based on the fully actuated system model, allowing a reduction in the number of variables sensed during implementation, resulting in only grid current and voltage being measured.https://ieeexplore.ieee.org/document/10982184/Finite control set model predictive controlfully actuated system (FAS)grid-connectedLCL filterleakage currentsingle-phase inverter
spellingShingle Cesar Limones
Nimrod Vazquez
Ricardo Femat
Leonel Estrada
Jeziel Vazquez
Claudia Hernandez
Angel de Castro
Joaquin Vaquero
Single-Phase Grid-Connected Inverter With Predictive Control Cost Function for Leakage Current Mitigation and FAS Model
IEEE Open Journal of the Industrial Electronics Society
Finite control set model predictive control
fully actuated system (FAS)
grid-connected
LCL filter
leakage current
single-phase inverter
title Single-Phase Grid-Connected Inverter With Predictive Control Cost Function for Leakage Current Mitigation and FAS Model
title_full Single-Phase Grid-Connected Inverter With Predictive Control Cost Function for Leakage Current Mitigation and FAS Model
title_fullStr Single-Phase Grid-Connected Inverter With Predictive Control Cost Function for Leakage Current Mitigation and FAS Model
title_full_unstemmed Single-Phase Grid-Connected Inverter With Predictive Control Cost Function for Leakage Current Mitigation and FAS Model
title_short Single-Phase Grid-Connected Inverter With Predictive Control Cost Function for Leakage Current Mitigation and FAS Model
title_sort single phase grid connected inverter with predictive control cost function for leakage current mitigation and fas model
topic Finite control set model predictive control
fully actuated system (FAS)
grid-connected
LCL filter
leakage current
single-phase inverter
url https://ieeexplore.ieee.org/document/10982184/
work_keys_str_mv AT cesarlimones singlephasegridconnectedinverterwithpredictivecontrolcostfunctionforleakagecurrentmitigationandfasmodel
AT nimrodvazquez singlephasegridconnectedinverterwithpredictivecontrolcostfunctionforleakagecurrentmitigationandfasmodel
AT ricardofemat singlephasegridconnectedinverterwithpredictivecontrolcostfunctionforleakagecurrentmitigationandfasmodel
AT leonelestrada singlephasegridconnectedinverterwithpredictivecontrolcostfunctionforleakagecurrentmitigationandfasmodel
AT jezielvazquez singlephasegridconnectedinverterwithpredictivecontrolcostfunctionforleakagecurrentmitigationandfasmodel
AT claudiahernandez singlephasegridconnectedinverterwithpredictivecontrolcostfunctionforleakagecurrentmitigationandfasmodel
AT angeldecastro singlephasegridconnectedinverterwithpredictivecontrolcostfunctionforleakagecurrentmitigationandfasmodel
AT joaquinvaquero singlephasegridconnectedinverterwithpredictivecontrolcostfunctionforleakagecurrentmitigationandfasmodel