VISUALIZATION OF BIOLOGICAL TISSUE IMPEDANCE PARAMETERS

Objective. Investigation the opportunity for measurement of biological tissue impedance to visualize its parameters.Materials and methods. Studies were undertook on the experimental facility, consists of registrating measuring cell, constructed from flat inductors system, formed in oscillatory circu...

Full description

Saved in:
Bibliographic Details
Main Author: V. I. Bankov
Format: Article
Language:English
Published: Siberian State Medical University (Tomsk) 2016-06-01
Series:Бюллетень сибирской медицины
Subjects:
Online Access:https://bulletin.ssmu.ru/jour/article/view/595
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849400236742541312
author V. I. Bankov
author_facet V. I. Bankov
author_sort V. I. Bankov
collection DOAJ
description Objective. Investigation the opportunity for measurement of biological tissue impedance to visualize its parameters.Materials and methods. Studies were undertook on the experimental facility, consists of registrating measuring cell, constructed from flat inductors system, formed in oscillatory circuit, herewith investigated biological tissue is the part of this oscillatory circuit. An excitation of oscillatory circuit fulfilled by means of exciter inductor which forms impulse complex modulated electromagnetic field (ICM EMF). The measurement process and visualizations provided by set of certificated instruments: a digital oscillograph AKTAKOM ADS-2221MV, a digital generator АКТАКОМ AWG-4150 (both with software) and a gauge RLC E7-22. Comparative dynamic studies of fixed volume and weight pig’s blood, adipose tissue, muscular tissue impedance were conducted by contact versus contactless methods. Contactless method in contrast to contact method gives opportunity to obtain the real morphological visualization of biological tissue irrespective of their nature.Results. Comparison of contact and contactless methods of impedance measurement shows that the inductance to capacitance ratio X(L) / X(C) was equal: 17 – for muscular tissue, 4 – for blood, 1 – for adipose tissue. It demonstrates the technical correspondence of both impedance registration methods. If propose the base relevance of X (L) and X (C) parameters for biological tissue impedance so contactless measurement method for sure shows insulating properties of adipose tissue and high conductivity for blood and muscular tissue in fixed volume-weight parameters. Registration of biological tissue impedance complex parameters by contactless method with the help of induced ICM EMF in fixed volume of biological tissue uncovers the most important informative volumes to characterize morphofunctional condition of biological tissue namely X (L) / X (C).Conclusion. Contactless method of biological tissue impedance measurement is more informative and dynamic and able to mirror morphologic features of organ’s tissue, since it does not depend from electric field divergence lines, electrode polarization and their localization, what takes place during contact method of impedance measurement. Contactless method of biological tissue impedance measurement can be applied as the base diagnostic method – dynamic volumogaraphy.
format Article
id doaj-art-4a57723fa5de449a8bc7fca989f580b4
institution Kabale University
issn 1682-0363
1819-3684
language English
publishDate 2016-06-01
publisher Siberian State Medical University (Tomsk)
record_format Article
series Бюллетень сибирской медицины
spelling doaj-art-4a57723fa5de449a8bc7fca989f580b42025-08-20T03:38:08ZengSiberian State Medical University (Tomsk)Бюллетень сибирской медицины1682-03631819-36842016-06-01153101510.20538/1682-0363-2016-3-10-15540VISUALIZATION OF BIOLOGICAL TISSUE IMPEDANCE PARAMETERSV. I. Bankov0Urals State Medicine University, EkaterinburgObjective. Investigation the opportunity for measurement of biological tissue impedance to visualize its parameters.Materials and methods. Studies were undertook on the experimental facility, consists of registrating measuring cell, constructed from flat inductors system, formed in oscillatory circuit, herewith investigated biological tissue is the part of this oscillatory circuit. An excitation of oscillatory circuit fulfilled by means of exciter inductor which forms impulse complex modulated electromagnetic field (ICM EMF). The measurement process and visualizations provided by set of certificated instruments: a digital oscillograph AKTAKOM ADS-2221MV, a digital generator АКТАКОМ AWG-4150 (both with software) and a gauge RLC E7-22. Comparative dynamic studies of fixed volume and weight pig’s blood, adipose tissue, muscular tissue impedance were conducted by contact versus contactless methods. Contactless method in contrast to contact method gives opportunity to obtain the real morphological visualization of biological tissue irrespective of their nature.Results. Comparison of contact and contactless methods of impedance measurement shows that the inductance to capacitance ratio X(L) / X(C) was equal: 17 – for muscular tissue, 4 – for blood, 1 – for adipose tissue. It demonstrates the technical correspondence of both impedance registration methods. If propose the base relevance of X (L) and X (C) parameters for biological tissue impedance so contactless measurement method for sure shows insulating properties of adipose tissue and high conductivity for blood and muscular tissue in fixed volume-weight parameters. Registration of biological tissue impedance complex parameters by contactless method with the help of induced ICM EMF in fixed volume of biological tissue uncovers the most important informative volumes to characterize morphofunctional condition of biological tissue namely X (L) / X (C).Conclusion. Contactless method of biological tissue impedance measurement is more informative and dynamic and able to mirror morphologic features of organ’s tissue, since it does not depend from electric field divergence lines, electrode polarization and their localization, what takes place during contact method of impedance measurement. Contactless method of biological tissue impedance measurement can be applied as the base diagnostic method – dynamic volumogaraphy.https://bulletin.ssmu.ru/jour/article/view/595biological tissue impedancediagnosticsdynamic volumogaraphy
spellingShingle V. I. Bankov
VISUALIZATION OF BIOLOGICAL TISSUE IMPEDANCE PARAMETERS
Бюллетень сибирской медицины
biological tissue impedance
diagnostics
dynamic volumogaraphy
title VISUALIZATION OF BIOLOGICAL TISSUE IMPEDANCE PARAMETERS
title_full VISUALIZATION OF BIOLOGICAL TISSUE IMPEDANCE PARAMETERS
title_fullStr VISUALIZATION OF BIOLOGICAL TISSUE IMPEDANCE PARAMETERS
title_full_unstemmed VISUALIZATION OF BIOLOGICAL TISSUE IMPEDANCE PARAMETERS
title_short VISUALIZATION OF BIOLOGICAL TISSUE IMPEDANCE PARAMETERS
title_sort visualization of biological tissue impedance parameters
topic biological tissue impedance
diagnostics
dynamic volumogaraphy
url https://bulletin.ssmu.ru/jour/article/view/595
work_keys_str_mv AT vibankov visualizationofbiologicaltissueimpedanceparameters