Immediate results of aortic valve replacement in elderly and senile patients using the Ozaki technique and Perceval S seamless biological prosthesis

The OBJECTIVE was to compare the immediate results of aortic valve replacement using Perceval S seamless biological prosthesis and aortic valve replacement using Ozaki technique.METHODS AND MATERIALS. From January 2021 to March 2022, 110 patients who underwent aortic valve replacement were analyzed....

Full description

Saved in:
Bibliographic Details
Main Authors: D. G. Gramatikov, V. S. Litus, V. K. Noginov
Format: Article
Language:Russian
Published: Pavlov First Saint Petersburg State Medical University 2023-07-01
Series:Вестник хирургии имени И.И. Грекова
Subjects:
Online Access:https://www.vestnik-grekova.ru/jour/article/view/2304
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849771883966234624
author D. G. Gramatikov
V. S. Litus
V. K. Noginov
author_facet D. G. Gramatikov
V. S. Litus
V. K. Noginov
author_sort D. G. Gramatikov
collection DOAJ
description The OBJECTIVE was to compare the immediate results of aortic valve replacement using Perceval S seamless biological prosthesis and aortic valve replacement using Ozaki technique.METHODS AND MATERIALS. From January 2021 to March 2022, 110 patients who underwent aortic valve replacement were analyzed. From this group, patients over 65 years of age with isolated aortic stenosis were selected, who underwent aortic valve replacement using Perceval S seamless biological prosthesis or replacement of aortic valve flaps using S. Ozaki technique. 2 groups were formed from the selected patients. Group 1 included patients over 65 years of age with isolated aortic stenosis (n=20), who underwent replacement of the aortic valve flaps using S. Ozaki technique. Group 2 included patients over 65 years of age with isolated aortic stenosis (n=20) who underwent aortic valve replacement using Perceval S seamless biological prosthesis.  RESULTS. There was a decrease in the average and peak pressure gradients on the aortic valve, as well as an increase in both the absolute effective and indexed effective area of the valve opening in the group of patients operated using S. Ozaki technique.  CONCLUSION. S. Ozaki surgery and aortic valve replacement using Perceval S seamless biological prosthesis demonstrate satisfactory immediate results of surgical treatment of aortic stenosis. The S. Ozaki technique reduces the likelihood of developing a “prosthesis-patient„ mismatch, but requires a longer time of myocardial ischemia.
format Article
id doaj-art-49e0d664e0c04beba798b1335afa959c
institution DOAJ
issn 0042-4625
language Russian
publishDate 2023-07-01
publisher Pavlov First Saint Petersburg State Medical University
record_format Article
series Вестник хирургии имени И.И. Грекова
spelling doaj-art-49e0d664e0c04beba798b1335afa959c2025-08-20T03:02:29ZrusPavlov First Saint Petersburg State Medical UniversityВестник хирургии имени И.И. Грекова0042-46252023-07-011816121810.24884/0042-4625-2022-181-6-12-181511Immediate results of aortic valve replacement in elderly and senile patients using the Ozaki technique and Perceval S seamless biological prosthesisD. G. Gramatikov0V. S. Litus1V. K. Noginov2Leningrad Regional Clinical HospitalLeningrad Regional Clinical HospitalLeningrad Regional Clinical HospitalThe OBJECTIVE was to compare the immediate results of aortic valve replacement using Perceval S seamless biological prosthesis and aortic valve replacement using Ozaki technique.METHODS AND MATERIALS. From January 2021 to March 2022, 110 patients who underwent aortic valve replacement were analyzed. From this group, patients over 65 years of age with isolated aortic stenosis were selected, who underwent aortic valve replacement using Perceval S seamless biological prosthesis or replacement of aortic valve flaps using S. Ozaki technique. 2 groups were formed from the selected patients. Group 1 included patients over 65 years of age with isolated aortic stenosis (n=20), who underwent replacement of the aortic valve flaps using S. Ozaki technique. Group 2 included patients over 65 years of age with isolated aortic stenosis (n=20) who underwent aortic valve replacement using Perceval S seamless biological prosthesis.  RESULTS. There was a decrease in the average and peak pressure gradients on the aortic valve, as well as an increase in both the absolute effective and indexed effective area of the valve opening in the group of patients operated using S. Ozaki technique.  CONCLUSION. S. Ozaki surgery and aortic valve replacement using Perceval S seamless biological prosthesis demonstrate satisfactory immediate results of surgical treatment of aortic stenosis. The S. Ozaki technique reduces the likelihood of developing a “prosthesis-patient„ mismatch, but requires a longer time of myocardial ischemia.https://www.vestnik-grekova.ru/jour/article/view/2304aortic stenosisaortic valve replacementozaki techniqueperceval s prosthesiselderly and senile age
spellingShingle D. G. Gramatikov
V. S. Litus
V. K. Noginov
Immediate results of aortic valve replacement in elderly and senile patients using the Ozaki technique and Perceval S seamless biological prosthesis
Вестник хирургии имени И.И. Грекова
aortic stenosis
aortic valve replacement
ozaki technique
perceval s prosthesis
elderly and senile age
title Immediate results of aortic valve replacement in elderly and senile patients using the Ozaki technique and Perceval S seamless biological prosthesis
title_full Immediate results of aortic valve replacement in elderly and senile patients using the Ozaki technique and Perceval S seamless biological prosthesis
title_fullStr Immediate results of aortic valve replacement in elderly and senile patients using the Ozaki technique and Perceval S seamless biological prosthesis
title_full_unstemmed Immediate results of aortic valve replacement in elderly and senile patients using the Ozaki technique and Perceval S seamless biological prosthesis
title_short Immediate results of aortic valve replacement in elderly and senile patients using the Ozaki technique and Perceval S seamless biological prosthesis
title_sort immediate results of aortic valve replacement in elderly and senile patients using the ozaki technique and perceval s seamless biological prosthesis
topic aortic stenosis
aortic valve replacement
ozaki technique
perceval s prosthesis
elderly and senile age
url https://www.vestnik-grekova.ru/jour/article/view/2304
work_keys_str_mv AT dggramatikov immediateresultsofaorticvalvereplacementinelderlyandsenilepatientsusingtheozakitechniqueandpercevalsseamlessbiologicalprosthesis
AT vslitus immediateresultsofaorticvalvereplacementinelderlyandsenilepatientsusingtheozakitechniqueandpercevalsseamlessbiologicalprosthesis
AT vknoginov immediateresultsofaorticvalvereplacementinelderlyandsenilepatientsusingtheozakitechniqueandpercevalsseamlessbiologicalprosthesis