Force distributions associated with different elastic traction methods for maxillary dentition distalization by clear aligners: an in-vitro study
Abstract Objective The aim of this study was to examine the distribution patterns of orthodontic and reactive forces on each tooth during dentition distalization using clear aligners (CAs), and to assess the impact of different elastic traction methods. Materials and methods Three sets of aligners f...
Saved in:
| Main Authors: | , , , , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
BMC
2025-04-01
|
| Series: | BMC Oral Health |
| Subjects: | |
| Online Access: | https://doi.org/10.1186/s12903-025-05985-5 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1850181552158277632 |
|---|---|
| author | Baolong Song Yizhe Qi Jianwei Sun Zexu Gu Rui Liu |
| author_facet | Baolong Song Yizhe Qi Jianwei Sun Zexu Gu Rui Liu |
| author_sort | Baolong Song |
| collection | DOAJ |
| description | Abstract Objective The aim of this study was to examine the distribution patterns of orthodontic and reactive forces on each tooth during dentition distalization using clear aligners (CAs), and to assess the impact of different elastic traction methods. Materials and methods Three sets of aligners for maxillary dentition distalization were fabricated, targeting different tooth movements: simultaneous distalization of the first molars and second premolars; simultaneous distalization of the first premolars and canines; and simultaneous retraction of incisors. An in vitro orthodontic simulator, consisting of 14 three-dimensional sensors, was used to evaluate mechanical changes in each tooth. The orthodontic and reactive forces exerted by aligners, along with additional pulling forces from 1/4 inch 3.5oz elastic using different elastic traction methods (with hooks or buttons), were measured and subjected to comparative analysis. Results The initial orthodontic force exerted by CAs varied across different teeth, ranging from 1.52 N to 6.77 N. Concurrently, the primary anchorage teeth experience reactive forces within a range of 1 N to 6.48 N. While the traction force on these teeth generally remained significantly smaller, staying below 0.6 N. The traction force exerted via hooks decayed to 84.3% and was primarily concentrated on the canines, whereas traction force applied via buttons transmitted approximately 96.1% and was more readily distributed to other teeth. Conclusion Elastic traction is not sufficient to completely counteract the initial reactive forces produced by the deformation of CAs. It is advisable to use stronger elastics or extend aligner wear time to ensure sufficient anchorage protection. Utilizing traction with buttons can reduce mechanical loss and enhance the transmission of traction force to other teeth. |
| format | Article |
| id | doaj-art-49a488e7f8154ca1a537fa1c9ecd583b |
| institution | OA Journals |
| issn | 1472-6831 |
| language | English |
| publishDate | 2025-04-01 |
| publisher | BMC |
| record_format | Article |
| series | BMC Oral Health |
| spelling | doaj-art-49a488e7f8154ca1a537fa1c9ecd583b2025-08-20T02:17:52ZengBMCBMC Oral Health1472-68312025-04-0125111010.1186/s12903-025-05985-5Force distributions associated with different elastic traction methods for maxillary dentition distalization by clear aligners: an in-vitro studyBaolong Song0Yizhe Qi1Jianwei Sun2Zexu Gu3Rui Liu4Department of Stomatology, Daping Hospital, Army Medical University (The Third Military Medical University)State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Clinical Research Center for Oral Diseases, Department of Orthodontics, School of Stomatology, The Fourth Military Medical UniversityState Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Clinical Research Center for Oral Diseases, Department of Orthodontics, School of Stomatology, The Fourth Military Medical UniversityState Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Clinical Research Center for Oral Diseases, Department of Orthodontics, School of Stomatology, The Fourth Military Medical UniversityDepartment of Stomatology, Daping Hospital, Army Medical University (The Third Military Medical University)Abstract Objective The aim of this study was to examine the distribution patterns of orthodontic and reactive forces on each tooth during dentition distalization using clear aligners (CAs), and to assess the impact of different elastic traction methods. Materials and methods Three sets of aligners for maxillary dentition distalization were fabricated, targeting different tooth movements: simultaneous distalization of the first molars and second premolars; simultaneous distalization of the first premolars and canines; and simultaneous retraction of incisors. An in vitro orthodontic simulator, consisting of 14 three-dimensional sensors, was used to evaluate mechanical changes in each tooth. The orthodontic and reactive forces exerted by aligners, along with additional pulling forces from 1/4 inch 3.5oz elastic using different elastic traction methods (with hooks or buttons), were measured and subjected to comparative analysis. Results The initial orthodontic force exerted by CAs varied across different teeth, ranging from 1.52 N to 6.77 N. Concurrently, the primary anchorage teeth experience reactive forces within a range of 1 N to 6.48 N. While the traction force on these teeth generally remained significantly smaller, staying below 0.6 N. The traction force exerted via hooks decayed to 84.3% and was primarily concentrated on the canines, whereas traction force applied via buttons transmitted approximately 96.1% and was more readily distributed to other teeth. Conclusion Elastic traction is not sufficient to completely counteract the initial reactive forces produced by the deformation of CAs. It is advisable to use stronger elastics or extend aligner wear time to ensure sufficient anchorage protection. Utilizing traction with buttons can reduce mechanical loss and enhance the transmission of traction force to other teeth.https://doi.org/10.1186/s12903-025-05985-5Orthodontic appliancesClear alignersForceThermoplastic applianceLatex elastics |
| spellingShingle | Baolong Song Yizhe Qi Jianwei Sun Zexu Gu Rui Liu Force distributions associated with different elastic traction methods for maxillary dentition distalization by clear aligners: an in-vitro study BMC Oral Health Orthodontic appliances Clear aligners Force Thermoplastic appliance Latex elastics |
| title | Force distributions associated with different elastic traction methods for maxillary dentition distalization by clear aligners: an in-vitro study |
| title_full | Force distributions associated with different elastic traction methods for maxillary dentition distalization by clear aligners: an in-vitro study |
| title_fullStr | Force distributions associated with different elastic traction methods for maxillary dentition distalization by clear aligners: an in-vitro study |
| title_full_unstemmed | Force distributions associated with different elastic traction methods for maxillary dentition distalization by clear aligners: an in-vitro study |
| title_short | Force distributions associated with different elastic traction methods for maxillary dentition distalization by clear aligners: an in-vitro study |
| title_sort | force distributions associated with different elastic traction methods for maxillary dentition distalization by clear aligners an in vitro study |
| topic | Orthodontic appliances Clear aligners Force Thermoplastic appliance Latex elastics |
| url | https://doi.org/10.1186/s12903-025-05985-5 |
| work_keys_str_mv | AT baolongsong forcedistributionsassociatedwithdifferentelastictractionmethodsformaxillarydentitiondistalizationbyclearalignersaninvitrostudy AT yizheqi forcedistributionsassociatedwithdifferentelastictractionmethodsformaxillarydentitiondistalizationbyclearalignersaninvitrostudy AT jianweisun forcedistributionsassociatedwithdifferentelastictractionmethodsformaxillarydentitiondistalizationbyclearalignersaninvitrostudy AT zexugu forcedistributionsassociatedwithdifferentelastictractionmethodsformaxillarydentitiondistalizationbyclearalignersaninvitrostudy AT ruiliu forcedistributionsassociatedwithdifferentelastictractionmethodsformaxillarydentitiondistalizationbyclearalignersaninvitrostudy |