Velocity-Constraint Kalman Filtering for Enhanced Bubble Tracking in Motion-Compensated Ultrasound Localization Microscopy
Ultrasound localization microscopy (ULM) is a novel imaging technique that overcomes the diffraction limit to achieve super-resolution imaging at the 10-μm scale. Despite its remarkable progress, challenges persist in enhancing the precision of microbubble tracking and fulfilling the requirements fo...
Saved in:
| Main Authors: | , , , , , , , , , , , , , , , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
American Association for the Advancement of Science (AAAS)
2025-01-01
|
| Series: | Research |
| Online Access: | https://spj.science.org/doi/10.34133/research.0725 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| Summary: | Ultrasound localization microscopy (ULM) is a novel imaging technique that overcomes the diffraction limit to achieve super-resolution imaging at the 10-μm scale. Despite its remarkable progress, challenges persist in enhancing the precision of microbubble tracking and fulfilling the requirements for high frame rates in practical circumstances, especially in moving organs. To address these issues, an enhanced ULM approach (shorten as vc-Kalman) integrating rapid motion compensation was developed to achieve excellent image quality. Unlike traditional methods relying on observed bubble positions, the proposed algorithm combined statistical information derived from historical data with Kalman-filter-predicted positions to enable more accurate bubble localization. Meanwhile, microbubble brightness in adjacent frames was incorporated as multidimensional feature to further improve the matching efficacy. Furthermore, velocity constraint was applied to minimize possible erroneous traces and enhance the contrast-to-noise ratio of ULM images, while ensuring the continuity of vascular reconstruction and the accuracy of the blood flow analysis to generate a reduced normalized root mean square error in velocity estimation, even at a relatively low frame rate of 146 Hz. More important, to effectively suppress the impact of physiological movements in moving organs like kidneys, this algorithm fulfilled subpixel displacement vector identification through parabolic fitting and expedited motion compensation via dynamic programming-based cross-correlation search. The results indicated that this advanced vc-Kalman method substantially boosted both the robustness and accuracy of ULM imaging, thereby opening more opportunities for clinical applications of super-resolution ULM technology. |
|---|---|
| ISSN: | 2639-5274 |