A multi-connected air conditioner with refrigerant and water using hot water from district heating system for direct heating

In many public buildings in northern China, direct expansion air conditioning systems are used for cooling, and the hot water from district heating networks is often used for heating, which requires two types of terminals. A multi-connected air conditioner with refrigerant and water using hot water...

Full description

Saved in:
Bibliographic Details
Main Authors: 查富海, 王 源, 李先庭, 国德防, 顾 超
Format: Article
Language:zho
Published: Journal of Refrigeration Magazines Agency Co., Ltd. 2025-01-01
Series:Zhileng xuebao
Subjects:
Online Access:http://www.zhilengxuebao.com/thesisDetails?columnId=67630373&Fpath=home&index=0
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850071478560620544
author 查富海
王 源
李先庭
国德防
顾 超
author_facet 查富海
王 源
李先庭
国德防
顾 超
author_sort 查富海
collection DOAJ
description In many public buildings in northern China, direct expansion air conditioning systems are used for cooling, and the hot water from district heating networks is often used for heating, which requires two types of terminals. A multi-connected air conditioner with refrigerant and water using hot water from district heating system for direct heating is proposed in this study. Three-fluid heat exchangers are used in the indoor units of the system, which can use hot water from district heating system or heat pumps for room heating, achieving flexible switching between direct expansion air conditioning system and district heating system. Taking an office building in Beijing as an example, the air conditioning system is selected in the summer designed condition. The simulation model of the system is established, and the heating effect of the system during the heating season and transition season is analyzed. The results show that the user side water temperature required for the system during the heating season is less than 54 ℃; when using direct expansion system during the transition season for heating, the unit capacity is higher than the peak heating load during the transition season, and the energy efficiency exceeds 3.5 within 49% of the operating time. The system proposed in this article utilizes one terminal to ensure summer cooling and winter heating needs, and can use direct expansion system for heating after district heating system shutdown, simplifying the existing system form and improving heating comfort.
format Article
id doaj-art-48c5dff54b144fee82110ca79f0b1cef
institution DOAJ
issn 0253-4339
language zho
publishDate 2025-01-01
publisher Journal of Refrigeration Magazines Agency Co., Ltd.
record_format Article
series Zhileng xuebao
spelling doaj-art-48c5dff54b144fee82110ca79f0b1cef2025-08-20T02:47:18ZzhoJournal of Refrigeration Magazines Agency Co., Ltd.Zhileng xuebao0253-43392025-01-0167630373A multi-connected air conditioner with refrigerant and water using hot water from district heating system for direct heating查富海王 源李先庭国德防顾 超In many public buildings in northern China, direct expansion air conditioning systems are used for cooling, and the hot water from district heating networks is often used for heating, which requires two types of terminals. A multi-connected air conditioner with refrigerant and water using hot water from district heating system for direct heating is proposed in this study. Three-fluid heat exchangers are used in the indoor units of the system, which can use hot water from district heating system or heat pumps for room heating, achieving flexible switching between direct expansion air conditioning system and district heating system. Taking an office building in Beijing as an example, the air conditioning system is selected in the summer designed condition. The simulation model of the system is established, and the heating effect of the system during the heating season and transition season is analyzed. The results show that the user side water temperature required for the system during the heating season is less than 54 ℃; when using direct expansion system during the transition season for heating, the unit capacity is higher than the peak heating load during the transition season, and the energy efficiency exceeds 3.5 within 49% of the operating time. The system proposed in this article utilizes one terminal to ensure summer cooling and winter heating needs, and can use direct expansion system for heating after district heating system shutdown, simplifying the existing system form and improving heating comfort.http://www.zhilengxuebao.com/thesisDetails?columnId=67630373&Fpath=home&index=0multi-connected air conditioner with refrigerant and waterthree-fluid heat exchangerair conditioning systemdistrict heating systemroom heating
spellingShingle 查富海
王 源
李先庭
国德防
顾 超
A multi-connected air conditioner with refrigerant and water using hot water from district heating system for direct heating
Zhileng xuebao
multi-connected air conditioner with refrigerant and water
three-fluid heat exchanger
air conditioning system
district heating system
room heating
title A multi-connected air conditioner with refrigerant and water using hot water from district heating system for direct heating
title_full A multi-connected air conditioner with refrigerant and water using hot water from district heating system for direct heating
title_fullStr A multi-connected air conditioner with refrigerant and water using hot water from district heating system for direct heating
title_full_unstemmed A multi-connected air conditioner with refrigerant and water using hot water from district heating system for direct heating
title_short A multi-connected air conditioner with refrigerant and water using hot water from district heating system for direct heating
title_sort multi connected air conditioner with refrigerant and water using hot water from district heating system for direct heating
topic multi-connected air conditioner with refrigerant and water
three-fluid heat exchanger
air conditioning system
district heating system
room heating
url http://www.zhilengxuebao.com/thesisDetails?columnId=67630373&Fpath=home&index=0
work_keys_str_mv AT cháfùhǎi amulticonnectedairconditionerwithrefrigerantandwaterusinghotwaterfromdistrictheatingsystemfordirectheating
AT wángyuán amulticonnectedairconditionerwithrefrigerantandwaterusinghotwaterfromdistrictheatingsystemfordirectheating
AT lǐxiāntíng amulticonnectedairconditionerwithrefrigerantandwaterusinghotwaterfromdistrictheatingsystemfordirectheating
AT guódéfáng amulticonnectedairconditionerwithrefrigerantandwaterusinghotwaterfromdistrictheatingsystemfordirectheating
AT gùchāo amulticonnectedairconditionerwithrefrigerantandwaterusinghotwaterfromdistrictheatingsystemfordirectheating
AT cháfùhǎi multiconnectedairconditionerwithrefrigerantandwaterusinghotwaterfromdistrictheatingsystemfordirectheating
AT wángyuán multiconnectedairconditionerwithrefrigerantandwaterusinghotwaterfromdistrictheatingsystemfordirectheating
AT lǐxiāntíng multiconnectedairconditionerwithrefrigerantandwaterusinghotwaterfromdistrictheatingsystemfordirectheating
AT guódéfáng multiconnectedairconditionerwithrefrigerantandwaterusinghotwaterfromdistrictheatingsystemfordirectheating
AT gùchāo multiconnectedairconditionerwithrefrigerantandwaterusinghotwaterfromdistrictheatingsystemfordirectheating