Influence of abutment material on peri-implant clinical parameters: a prospective study
Objective: This study evaluated the peri-implant clinical parameters of zirconia versus metallic abutments for standardized custom-made implantsupported single-tooth restorations. Material and Methods: Sixteen subjects received 30 dental implants on esthetic region of upper jaws. Test group had 14...
Saved in:
| Main Authors: | , , , , , , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Universidade Estadual Paulista
2014-08-01
|
| Series: | Brazilian Dental Science |
| Online Access: | https://ojs.ict.unesp.br/index.php/cob/article/view/972 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1849228647112638464 |
|---|---|
| author | Fabiano Cortez Zanardo José Della Pasqua Neto Luiz Henrique Alves Madeira Jamil Awad Shibli Keize Távora Barbosa José Augusto Rodrigues Alessandra Cassoni |
| author_facet | Fabiano Cortez Zanardo José Della Pasqua Neto Luiz Henrique Alves Madeira Jamil Awad Shibli Keize Távora Barbosa José Augusto Rodrigues Alessandra Cassoni |
| author_sort | Fabiano Cortez Zanardo |
| collection | DOAJ |
| description |
Objective: This study evaluated the peri-implant clinical parameters of zirconia versus metallic abutments for standardized custom-made implantsupported single-tooth restorations. Material and Methods: Sixteen subjects received 30 dental implants on esthetic region of upper jaws. Test group had 14 implant-supported single-tooth restorations with ceramic abutment and control group had 16 restorations with metallic abutment. Peri-implant clinical parameters were recorded after 110 ± 10 days in function at six sites by each implant, in each subject. The means of clinical measures: probing depth (PD) and clinical attachment level (CAL); mean of percentages of sites with visible plaque (VP), bleeding on probing (BOP) and suppuration (SU) were recorded to each subject. To verify differences between groups Mann Whitney U-test was selected PD and CAL and k-light test VP, BOP and SU. Results: One zirconia implant-supported single-tooth restoration fractured at insertion time. The mean of PD, CAL, and BOP of the samples sites were lower to test group than control (p < 0.05). There were no differences of mean levels of VP and S between test and control group (p > 0.05). Conclusion: Clinical parameters around implant-supported restorations were influenced by abutment type with better results to zirconia abutments, at least, after short time period evaluation.
|
| format | Article |
| id | doaj-art-475c82a0c77148d7a2aae79677c9aeef |
| institution | Kabale University |
| issn | 2178-6011 |
| language | English |
| publishDate | 2014-08-01 |
| publisher | Universidade Estadual Paulista |
| record_format | Article |
| series | Brazilian Dental Science |
| spelling | doaj-art-475c82a0c77148d7a2aae79677c9aeef2025-08-22T17:54:40ZengUniversidade Estadual PaulistaBrazilian Dental Science2178-60112014-08-0117310.14295/bds.2014.v17i3.972Influence of abutment material on peri-implant clinical parameters: a prospective studyFabiano Cortez Zanardo0José Della Pasqua Neto1Luiz Henrique Alves Madeira2Jamil Awad Shibli3Keize Távora Barbosa4José Augusto Rodrigues5Alessandra Cassoni6Dental Research Division - Department of Implant Dentistry - Guarulhos University - Guarulhos - SP - Brazil.Dental Research Division - Department of Implant Dentistry - Guarulhos University - Guarulhos - SP - Brazil.Dental Research Division - Department of Implant Dentistry - Guarulhos University - Guarulhos - SP - Brazil.Dental Research Division - Department of Implant Dentistry - Guarulhos University - Guarulhos - SP - Brazil.Dental Research Division - Department of Implant Dentistry - Guarulhos University - Guarulhos - SP - Brazil.Dental Research Division - Department of Restorative and Implant Dentistry - Guarulhos University - Guarulhos - SP - Brazil.Dental Research Division - Department of Restorative and Implant Dentistry - Guarulhos University - Guarulhos - SP - Brazil. Objective: This study evaluated the peri-implant clinical parameters of zirconia versus metallic abutments for standardized custom-made implantsupported single-tooth restorations. Material and Methods: Sixteen subjects received 30 dental implants on esthetic region of upper jaws. Test group had 14 implant-supported single-tooth restorations with ceramic abutment and control group had 16 restorations with metallic abutment. Peri-implant clinical parameters were recorded after 110 ± 10 days in function at six sites by each implant, in each subject. The means of clinical measures: probing depth (PD) and clinical attachment level (CAL); mean of percentages of sites with visible plaque (VP), bleeding on probing (BOP) and suppuration (SU) were recorded to each subject. To verify differences between groups Mann Whitney U-test was selected PD and CAL and k-light test VP, BOP and SU. Results: One zirconia implant-supported single-tooth restoration fractured at insertion time. The mean of PD, CAL, and BOP of the samples sites were lower to test group than control (p < 0.05). There were no differences of mean levels of VP and S between test and control group (p > 0.05). Conclusion: Clinical parameters around implant-supported restorations were influenced by abutment type with better results to zirconia abutments, at least, after short time period evaluation. https://ojs.ict.unesp.br/index.php/cob/article/view/972 |
| spellingShingle | Fabiano Cortez Zanardo José Della Pasqua Neto Luiz Henrique Alves Madeira Jamil Awad Shibli Keize Távora Barbosa José Augusto Rodrigues Alessandra Cassoni Influence of abutment material on peri-implant clinical parameters: a prospective study Brazilian Dental Science |
| title | Influence of abutment material on peri-implant clinical parameters: a prospective study |
| title_full | Influence of abutment material on peri-implant clinical parameters: a prospective study |
| title_fullStr | Influence of abutment material on peri-implant clinical parameters: a prospective study |
| title_full_unstemmed | Influence of abutment material on peri-implant clinical parameters: a prospective study |
| title_short | Influence of abutment material on peri-implant clinical parameters: a prospective study |
| title_sort | influence of abutment material on peri implant clinical parameters a prospective study |
| url | https://ojs.ict.unesp.br/index.php/cob/article/view/972 |
| work_keys_str_mv | AT fabianocortezzanardo influenceofabutmentmaterialonperiimplantclinicalparametersaprospectivestudy AT josedellapasquaneto influenceofabutmentmaterialonperiimplantclinicalparametersaprospectivestudy AT luizhenriquealvesmadeira influenceofabutmentmaterialonperiimplantclinicalparametersaprospectivestudy AT jamilawadshibli influenceofabutmentmaterialonperiimplantclinicalparametersaprospectivestudy AT keizetavorabarbosa influenceofabutmentmaterialonperiimplantclinicalparametersaprospectivestudy AT joseaugustorodrigues influenceofabutmentmaterialonperiimplantclinicalparametersaprospectivestudy AT alessandracassoni influenceofabutmentmaterialonperiimplantclinicalparametersaprospectivestudy |