Dual chamber pacemaker in the treatment of paroxysmal atrial fibrillation

Background. Atrial fibrillation is the most frequent cardiac dysrhythmia. The aim of this study was to show the role and the efficacy of a dual chamber pacemaker with the algorithm of atrial dynamic overdrive, in the suppression of paroxysmal atrial fibrillation. Case report. A woman with a classica...

Full description

Saved in:
Bibliographic Details
Main Authors: Rađen Goran, Rafajlovski Saša I., Perišić Zoran, Romanović Radoslav
Format: Article
Language:English
Published: Ministry of Defence of the Republic of Serbia, University of Defence, Belgrade 2005-01-01
Series:Vojnosanitetski Pregled
Subjects:
Online Access:http://www.doiserbia.nb.rs/img/doi/0042-8450/2005/0042-84500504329R.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849406900687339520
author Rađen Goran
Rafajlovski Saša I.
Perišić Zoran
Romanović Radoslav
author_facet Rađen Goran
Rafajlovski Saša I.
Perišić Zoran
Romanović Radoslav
author_sort Rađen Goran
collection DOAJ
description Background. Atrial fibrillation is the most frequent cardiac dysrhythmia. The aim of this study was to show the role and the efficacy of a dual chamber pacemaker with the algorithm of atrial dynamic overdrive, in the suppression of paroxysmal atrial fibrillation. Case report. A woman with a classical bradycardia-tachycardia syndrome, and frequent attacks of atrial fibrillation, underwent the implantation of a single chamber permanent pacemaker (VVI). Pacemaker successfully treated the episodes of symptomatic bradycardia, but the patient had frequent attacks of atrial fibrillation, despite the use of different antiarrhythmic drugs, which she did not tolerate well. The decision was made to reimplant a permanent dual chamber pacemaker with the algorithm of atrial dynamic overdrive. The pacemaker was programmed to the basic rate of 75/min, while rate at rest was 55/min. In addition, sotalol was administered. After three months, the patient became asymptomatic with only 4 short − term episodes of atrial fibrillation, and a high level of atrial pacing (99%). Conclusion. In selected patients with bradycardia−tachycardia syndrome, atrial-based pacing seemed to be very effective in reducing the incidence of paroxysmal atrial fibrillation.
format Article
id doaj-art-462f832f4b7841c795041b0530422bb2
institution Kabale University
issn 0042-8450
language English
publishDate 2005-01-01
publisher Ministry of Defence of the Republic of Serbia, University of Defence, Belgrade
record_format Article
series Vojnosanitetski Pregled
spelling doaj-art-462f832f4b7841c795041b0530422bb22025-08-20T03:36:14ZengMinistry of Defence of the Republic of Serbia, University of Defence, BelgradeVojnosanitetski Pregled0042-84502005-01-0162432933410.2298/VSP0504329RDual chamber pacemaker in the treatment of paroxysmal atrial fibrillationRađen GoranRafajlovski Saša I.Perišić ZoranRomanović RadoslavBackground. Atrial fibrillation is the most frequent cardiac dysrhythmia. The aim of this study was to show the role and the efficacy of a dual chamber pacemaker with the algorithm of atrial dynamic overdrive, in the suppression of paroxysmal atrial fibrillation. Case report. A woman with a classical bradycardia-tachycardia syndrome, and frequent attacks of atrial fibrillation, underwent the implantation of a single chamber permanent pacemaker (VVI). Pacemaker successfully treated the episodes of symptomatic bradycardia, but the patient had frequent attacks of atrial fibrillation, despite the use of different antiarrhythmic drugs, which she did not tolerate well. The decision was made to reimplant a permanent dual chamber pacemaker with the algorithm of atrial dynamic overdrive. The pacemaker was programmed to the basic rate of 75/min, while rate at rest was 55/min. In addition, sotalol was administered. After three months, the patient became asymptomatic with only 4 short − term episodes of atrial fibrillation, and a high level of atrial pacing (99%). Conclusion. In selected patients with bradycardia−tachycardia syndrome, atrial-based pacing seemed to be very effective in reducing the incidence of paroxysmal atrial fibrillation.http://www.doiserbia.nb.rs/img/doi/0042-8450/2005/0042-84500504329R.pdfatrial fibrillationcardiac pacingartificialpacemakerartificialbradycardiatachycardia
spellingShingle Rađen Goran
Rafajlovski Saša I.
Perišić Zoran
Romanović Radoslav
Dual chamber pacemaker in the treatment of paroxysmal atrial fibrillation
Vojnosanitetski Pregled
atrial fibrillation
cardiac pacing
artificial
pacemaker
artificial
bradycardia
tachycardia
title Dual chamber pacemaker in the treatment of paroxysmal atrial fibrillation
title_full Dual chamber pacemaker in the treatment of paroxysmal atrial fibrillation
title_fullStr Dual chamber pacemaker in the treatment of paroxysmal atrial fibrillation
title_full_unstemmed Dual chamber pacemaker in the treatment of paroxysmal atrial fibrillation
title_short Dual chamber pacemaker in the treatment of paroxysmal atrial fibrillation
title_sort dual chamber pacemaker in the treatment of paroxysmal atrial fibrillation
topic atrial fibrillation
cardiac pacing
artificial
pacemaker
artificial
bradycardia
tachycardia
url http://www.doiserbia.nb.rs/img/doi/0042-8450/2005/0042-84500504329R.pdf
work_keys_str_mv AT rađengoran dualchamberpacemakerinthetreatmentofparoxysmalatrialfibrillation
AT rafajlovskisasai dualchamberpacemakerinthetreatmentofparoxysmalatrialfibrillation
AT perisiczoran dualchamberpacemakerinthetreatmentofparoxysmalatrialfibrillation
AT romanovicradoslav dualchamberpacemakerinthetreatmentofparoxysmalatrialfibrillation