Evaluation of accuracy of OraQuick® rapid test in detecting HIV antibodies in saliva of Nigerians

Objective: The accuracy of OraQuick® rapid test in detecting HIV 1 & 2 antibodies in saliva is evaluated against the blood EIA benchmark tests with confirmatory testing, against which OraQuick® accuracy is determined. Method: Paired samples of saliva and blood from 281 Nigerians were tested for...

Full description

Saved in:
Bibliographic Details
Main Authors: M.C. Nwoga, O. Odukoya, K.O. Savage, O.A. Effiom
Format: Article
Language:English
Published: Nigerian Dental Association 2012-07-01
Series:Nigerian Dental Journal
Subjects:
Online Access:https://nigeriandentaljournal.ng/index.php/ndj/article/view/108
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850162444136087552
author M.C. Nwoga
O. Odukoya
K.O. Savage
O.A. Effiom
author_facet M.C. Nwoga
O. Odukoya
K.O. Savage
O.A. Effiom
author_sort M.C. Nwoga
collection DOAJ
description Objective: The accuracy of OraQuick® rapid test in detecting HIV 1 & 2 antibodies in saliva is evaluated against the blood EIA benchmark tests with confirmatory testing, against which OraQuick® accuracy is determined. Method: Paired samples of saliva and blood from 281 Nigerians were tested for HIV antibodies, and compared for sensitivity and specificity. Subjects included in the study were  those who had a complete test, which included saliva test with OraQuick® rapid test, serologic test using conventional Enzyme Immunoassay (EIA), and confirmatory serological test. Result: From the 281 subjects who completed the oral fluid-based OraQuick® tests & EIA with confirmatory tests, 192 were seropositive and 89 seronegative for HIV 1 & 2 antibodies. The  sensitivity (95% CI) of OraQuick® was 98.96% (97.98% to 99.96%) and specificity was 100% thereby comparing favorably with serum EIA with benchmark sensitivity of 100% and specificity (95% CI) of 96.63% (95.61 to 97.56). Conclusion: Saliva based OraQuick® rapid assays for detecting HIV antibodies using oral fluids give accurate sensitivity and specificity results comparable to EIA results with serum samples. They are more acceptable, easier to use and not invasive.
format Article
id doaj-art-462e5ffb1eb745c1ae5497282d2c0bfe
institution OA Journals
issn 0189-1006
language English
publishDate 2012-07-01
publisher Nigerian Dental Association
record_format Article
series Nigerian Dental Journal
spelling doaj-art-462e5ffb1eb745c1ae5497282d2c0bfe2025-08-20T02:22:34ZengNigerian Dental AssociationNigerian Dental Journal0189-10062012-07-0120210.61172/ndj.v20i2.108Evaluation of accuracy of OraQuick® rapid test in detecting HIV antibodies in saliva of NigeriansM.C. NwogaO. OdukoyaK.O. SavageO.A. Effiom Objective: The accuracy of OraQuick® rapid test in detecting HIV 1 & 2 antibodies in saliva is evaluated against the blood EIA benchmark tests with confirmatory testing, against which OraQuick® accuracy is determined. Method: Paired samples of saliva and blood from 281 Nigerians were tested for HIV antibodies, and compared for sensitivity and specificity. Subjects included in the study were  those who had a complete test, which included saliva test with OraQuick® rapid test, serologic test using conventional Enzyme Immunoassay (EIA), and confirmatory serological test. Result: From the 281 subjects who completed the oral fluid-based OraQuick® tests & EIA with confirmatory tests, 192 were seropositive and 89 seronegative for HIV 1 & 2 antibodies. The  sensitivity (95% CI) of OraQuick® was 98.96% (97.98% to 99.96%) and specificity was 100% thereby comparing favorably with serum EIA with benchmark sensitivity of 100% and specificity (95% CI) of 96.63% (95.61 to 97.56). Conclusion: Saliva based OraQuick® rapid assays for detecting HIV antibodies using oral fluids give accurate sensitivity and specificity results comparable to EIA results with serum samples. They are more acceptable, easier to use and not invasive. https://nigeriandentaljournal.ng/index.php/ndj/article/view/108OraquickSalivaHIV detection
spellingShingle M.C. Nwoga
O. Odukoya
K.O. Savage
O.A. Effiom
Evaluation of accuracy of OraQuick® rapid test in detecting HIV antibodies in saliva of Nigerians
Nigerian Dental Journal
Oraquick
Saliva
HIV detection
title Evaluation of accuracy of OraQuick® rapid test in detecting HIV antibodies in saliva of Nigerians
title_full Evaluation of accuracy of OraQuick® rapid test in detecting HIV antibodies in saliva of Nigerians
title_fullStr Evaluation of accuracy of OraQuick® rapid test in detecting HIV antibodies in saliva of Nigerians
title_full_unstemmed Evaluation of accuracy of OraQuick® rapid test in detecting HIV antibodies in saliva of Nigerians
title_short Evaluation of accuracy of OraQuick® rapid test in detecting HIV antibodies in saliva of Nigerians
title_sort evaluation of accuracy of oraquick r rapid test in detecting hiv antibodies in saliva of nigerians
topic Oraquick
Saliva
HIV detection
url https://nigeriandentaljournal.ng/index.php/ndj/article/view/108
work_keys_str_mv AT mcnwoga evaluationofaccuracyoforaquickrapidtestindetectinghivantibodiesinsalivaofnigerians
AT oodukoya evaluationofaccuracyoforaquickrapidtestindetectinghivantibodiesinsalivaofnigerians
AT kosavage evaluationofaccuracyoforaquickrapidtestindetectinghivantibodiesinsalivaofnigerians
AT oaeffiom evaluationofaccuracyoforaquickrapidtestindetectinghivantibodiesinsalivaofnigerians