The Effect of Different Angled Abutments with Peripheral Groove and Vent Hole on the Retention of Cement Retained Implant – Supported Restorations

Background: The purpose of this study was to analyze the effect of vent hole or peripheral groove on retention of differently angled (15 ° and 30 o) abutments in of cement retained implant supported restorations. Methods: A total of sixty standart implant abutments were used. Abutments were divided...

Full description

Saved in:
Bibliographic Details
Main Authors: Nuran Yanıkoğlu, Hilal Asutay
Format: Article
Language:English
Published: Selcuk University Press 2024-04-01
Series:Selcuk Dental Journal
Subjects:
Online Access:https://dergipark.org.tr/tr/download/article-file/2892663
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1841561989657133056
author Nuran Yanıkoğlu
Hilal Asutay
author_facet Nuran Yanıkoğlu
Hilal Asutay
author_sort Nuran Yanıkoğlu
collection DOAJ
description Background: The purpose of this study was to analyze the effect of vent hole or peripheral groove on retention of differently angled (15 ° and 30 o) abutments in of cement retained implant supported restorations. Methods: A total of sixty standart implant abutments were used. Abutments were divided into two groups at 15 ° and 30 ° angles on CNC. According to the modification, each group were divided into 3 subgroups; (1) no modifications, (2) with peripheral groove and (3) with vent hole. Sixty metal frameworks were prepared using laser sintering to fit all abutments. All laser sintered frameworks were cemented with eugenol-free provisional cement. Then, all specimens were thermocycled. The frameworks were removed from the abutments by using the universal test machine and the peak removal force was recorded. Statistical analysis were performed with two-way ANOVA, post hoc Tukey’s (HSD) test-adjusted independent samples t-tests. Results: According to the results, there were significant differences between 15 ° and 30 ° groups in terms of retention values (p < 0.001). Additional hole and grooves enhanced retention in both groups. The highest mean value of vertical pull-out strength (185.00 ± 23.08 N) was showed in 15 ° additional grooves group, and the lowest mean value of vertical pull-out strength (27.60 ± 14.84 N) was showed in 30° control group. Means values of additional groove specimens had the highest scores in both groups. In all groups, there were significant differences between all subgroups (p < 0.05). Conclusion: Increased abutment angle decreases retention, while addition of hole and groove increases.
format Article
id doaj-art-443f42bce9b84f5097a4df6494a47ad6
institution Kabale University
issn 2148-7529
language English
publishDate 2024-04-01
publisher Selcuk University Press
record_format Article
series Selcuk Dental Journal
spelling doaj-art-443f42bce9b84f5097a4df6494a47ad62025-01-03T01:13:47ZengSelcuk University PressSelcuk Dental Journal2148-75292024-04-01111495410.15311/selcukdentj.1234649154The Effect of Different Angled Abutments with Peripheral Groove and Vent Hole on the Retention of Cement Retained Implant – Supported RestorationsNuran Yanıkoğlu0Hilal Asutay1ATATURK UNIVERSITYPrivate Practice, Uzman DentaClinicBackground: The purpose of this study was to analyze the effect of vent hole or peripheral groove on retention of differently angled (15 ° and 30 o) abutments in of cement retained implant supported restorations. Methods: A total of sixty standart implant abutments were used. Abutments were divided into two groups at 15 ° and 30 ° angles on CNC. According to the modification, each group were divided into 3 subgroups; (1) no modifications, (2) with peripheral groove and (3) with vent hole. Sixty metal frameworks were prepared using laser sintering to fit all abutments. All laser sintered frameworks were cemented with eugenol-free provisional cement. Then, all specimens were thermocycled. The frameworks were removed from the abutments by using the universal test machine and the peak removal force was recorded. Statistical analysis were performed with two-way ANOVA, post hoc Tukey’s (HSD) test-adjusted independent samples t-tests. Results: According to the results, there were significant differences between 15 ° and 30 ° groups in terms of retention values (p < 0.001). Additional hole and grooves enhanced retention in both groups. The highest mean value of vertical pull-out strength (185.00 ± 23.08 N) was showed in 15 ° additional grooves group, and the lowest mean value of vertical pull-out strength (27.60 ± 14.84 N) was showed in 30° control group. Means values of additional groove specimens had the highest scores in both groups. In all groups, there were significant differences between all subgroups (p < 0.05). Conclusion: Increased abutment angle decreases retention, while addition of hole and groove increases.https://dergipark.org.tr/tr/download/article-file/2892663tutuculuksimante implantsimanimplantimplant-supported dental prothesisdental implantcementationabutmentretantion
spellingShingle Nuran Yanıkoğlu
Hilal Asutay
The Effect of Different Angled Abutments with Peripheral Groove and Vent Hole on the Retention of Cement Retained Implant – Supported Restorations
Selcuk Dental Journal
tutuculuk
simante implant
siman
implant
implant-supported dental prothesis
dental implant
cementation
abutment
retantion
title The Effect of Different Angled Abutments with Peripheral Groove and Vent Hole on the Retention of Cement Retained Implant – Supported Restorations
title_full The Effect of Different Angled Abutments with Peripheral Groove and Vent Hole on the Retention of Cement Retained Implant – Supported Restorations
title_fullStr The Effect of Different Angled Abutments with Peripheral Groove and Vent Hole on the Retention of Cement Retained Implant – Supported Restorations
title_full_unstemmed The Effect of Different Angled Abutments with Peripheral Groove and Vent Hole on the Retention of Cement Retained Implant – Supported Restorations
title_short The Effect of Different Angled Abutments with Peripheral Groove and Vent Hole on the Retention of Cement Retained Implant – Supported Restorations
title_sort effect of different angled abutments with peripheral groove and vent hole on the retention of cement retained implant supported restorations
topic tutuculuk
simante implant
siman
implant
implant-supported dental prothesis
dental implant
cementation
abutment
retantion
url https://dergipark.org.tr/tr/download/article-file/2892663
work_keys_str_mv AT nuranyanıkoglu theeffectofdifferentangledabutmentswithperipheralgrooveandventholeontheretentionofcementretainedimplantsupportedrestorations
AT hilalasutay theeffectofdifferentangledabutmentswithperipheralgrooveandventholeontheretentionofcementretainedimplantsupportedrestorations
AT nuranyanıkoglu effectofdifferentangledabutmentswithperipheralgrooveandventholeontheretentionofcementretainedimplantsupportedrestorations
AT hilalasutay effectofdifferentangledabutmentswithperipheralgrooveandventholeontheretentionofcementretainedimplantsupportedrestorations