Comparative Study of Gamma- Ray Shielding Parameters for Different Epoxy Composites

In the current work various types of epoxy composites were added to concrete to enhance its effectiveness as a gamma- ray shield. Four epoxy samples of (E/clay/B4C) S1, (E/Mag/B4C) S2, (EPIL) S3 and (Ep) S4 were used in a comparative study of gamma radiation attenuation properties of these shields...

Full description

Saved in:
Bibliographic Details
Main Authors: Amal A. El- Sawy, Eman Sarwat
Format: Article
Language:English
Published: University of Baghdad, College of Science for Women 2024-02-01
Series:مجلة بغداد للعلوم
Subjects:
Online Access:https://bsj.uobaghdad.edu.iq/index.php/BSJ/article/view/7685
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849246941818388480
author Amal A. El- Sawy
Eman Sarwat
author_facet Amal A. El- Sawy
Eman Sarwat
author_sort Amal A. El- Sawy
collection DOAJ
description In the current work various types of epoxy composites were added to concrete to enhance its effectiveness as a gamma- ray shield. Four epoxy samples of (E/clay/B4C) S1, (E/Mag/B4C) S2, (EPIL) S3 and (Ep) S4 were used in a comparative study of gamma radiation attenuation properties of these shields that calculating using Mont Carlo code (MCNP-5). Adopting Win X-com software and Artificial Neural Network (ANN), µ/ρ revealed great compliance with MCNP-5. By applying (µ/ρ) output for gamma at different energies, HVL, TVL and MFP have been also estimated. ANN technique was simulated to estimate (µ/ρ) and dose rates. According to the results, µ/ρ of all epoxy samples scored higher than standard concrete. Both S2 and S3 samples having higher values of µ/ρ, show minimum dose rate values. (µ/ρ) and RPE% values were enhanced, the concrete containing E/Mag/B4C (S2) had the best results, while the concrete containing Ep (S4) provide the worst results. The ANN prediction results take 15 sec for estimating gamma doses corresponding to seventeen shield thicknesses, while the theoretical MCNP-5 results took approximately between 7 to 10 hours for five gamma doses. ANN provides excellent predictions with a high degree of correlation depending on increasing the number of attenuation parameters used in the training process. Also, it predicts gamma dose rates for a large number of shield thicknesses that cannot be calculated theoretically in a very short time. This supports, the created epoxy composite offers good attenuation properties for many shielding applications and could be proposed as an injecting mortar for cracks in biological shields and the walls of diagnostic and radiotherapy rooms. However, further investigations are planned for different filler ratios, for comparison purposes, in order to reach optimal shielding properties
format Article
id doaj-art-43c1c3f7155a438fb9cfddc22bcbe63a
institution Kabale University
issn 2078-8665
2411-7986
language English
publishDate 2024-02-01
publisher University of Baghdad, College of Science for Women
record_format Article
series مجلة بغداد للعلوم
spelling doaj-art-43c1c3f7155a438fb9cfddc22bcbe63a2025-08-20T03:58:21ZengUniversity of Baghdad, College of Science for Womenمجلة بغداد للعلوم2078-86652411-79862024-02-0121210.21123/bsj.2023.7685Comparative Study of Gamma- Ray Shielding Parameters for Different Epoxy CompositesAmal A. El- Sawy0Eman Sarwat 1Nuclear and Radiological Safety Research Center, Egyptian Atomic Energy Authority Nuclear and Radiological Safety Research Center, Egyptian Atomic Energy Authority In the current work various types of epoxy composites were added to concrete to enhance its effectiveness as a gamma- ray shield. Four epoxy samples of (E/clay/B4C) S1, (E/Mag/B4C) S2, (EPIL) S3 and (Ep) S4 were used in a comparative study of gamma radiation attenuation properties of these shields that calculating using Mont Carlo code (MCNP-5). Adopting Win X-com software and Artificial Neural Network (ANN), µ/ρ revealed great compliance with MCNP-5. By applying (µ/ρ) output for gamma at different energies, HVL, TVL and MFP have been also estimated. ANN technique was simulated to estimate (µ/ρ) and dose rates. According to the results, µ/ρ of all epoxy samples scored higher than standard concrete. Both S2 and S3 samples having higher values of µ/ρ, show minimum dose rate values. (µ/ρ) and RPE% values were enhanced, the concrete containing E/Mag/B4C (S2) had the best results, while the concrete containing Ep (S4) provide the worst results. The ANN prediction results take 15 sec for estimating gamma doses corresponding to seventeen shield thicknesses, while the theoretical MCNP-5 results took approximately between 7 to 10 hours for five gamma doses. ANN provides excellent predictions with a high degree of correlation depending on increasing the number of attenuation parameters used in the training process. Also, it predicts gamma dose rates for a large number of shield thicknesses that cannot be calculated theoretically in a very short time. This supports, the created epoxy composite offers good attenuation properties for many shielding applications and could be proposed as an injecting mortar for cracks in biological shields and the walls of diagnostic and radiotherapy rooms. However, further investigations are planned for different filler ratios, for comparison purposes, in order to reach optimal shielding properties https://bsj.uobaghdad.edu.iq/index.php/BSJ/article/view/7685ANN technique, Mass attenuation coefficient (µ/ρ), MCNP-5 model, Radiation shielding, Epoxy composite, Radiation protection efficiency (RPE%).
spellingShingle Amal A. El- Sawy
Eman Sarwat
Comparative Study of Gamma- Ray Shielding Parameters for Different Epoxy Composites
مجلة بغداد للعلوم
ANN technique, Mass attenuation coefficient (µ/ρ), MCNP-5 model, Radiation shielding, Epoxy composite, Radiation protection efficiency (RPE%).
title Comparative Study of Gamma- Ray Shielding Parameters for Different Epoxy Composites
title_full Comparative Study of Gamma- Ray Shielding Parameters for Different Epoxy Composites
title_fullStr Comparative Study of Gamma- Ray Shielding Parameters for Different Epoxy Composites
title_full_unstemmed Comparative Study of Gamma- Ray Shielding Parameters for Different Epoxy Composites
title_short Comparative Study of Gamma- Ray Shielding Parameters for Different Epoxy Composites
title_sort comparative study of gamma ray shielding parameters for different epoxy composites
topic ANN technique, Mass attenuation coefficient (µ/ρ), MCNP-5 model, Radiation shielding, Epoxy composite, Radiation protection efficiency (RPE%).
url https://bsj.uobaghdad.edu.iq/index.php/BSJ/article/view/7685
work_keys_str_mv AT amalaelsawy comparativestudyofgammarayshieldingparametersfordifferentepoxycomposites
AT emansarwat comparativestudyofgammarayshieldingparametersfordifferentepoxycomposites