Study on The Method of Suppressing Cycle Power during Up-shift Process for Wet Dual Clutch Transmission

The cycle power,which is prone to appear during shifting process for a wet dual clutch transmission,the life of the clutch is severely affected and the shifting quality is decreased. In response to this phenomenon,the up- shift dynamics equations are derived according to the detailed analysis of up-...

Full description

Saved in:
Bibliographic Details
Main Authors: Qu Siyu, Chen Man, Liu Jikai, Gao Song
Format: Article
Language:zho
Published: Editorial Office of Journal of Mechanical Transmission 2016-01-01
Series:Jixie chuandong
Subjects:
Online Access:http://www.jxcd.net.cn/thesisDetails#10.16578/j.issn.1004.2539.2016.10.011
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1841547963511341056
author Qu Siyu
Chen Man
Liu Jikai
Gao Song
author_facet Qu Siyu
Chen Man
Liu Jikai
Gao Song
author_sort Qu Siyu
collection DOAJ
description The cycle power,which is prone to appear during shifting process for a wet dual clutch transmission,the life of the clutch is severely affected and the shifting quality is decreased. In response to this phenomenon,the up- shift dynamics equations are derived according to the detailed analysis of up- shifts and the study on the cause of cycle power,during up- shift process of a DCT. Furthermore,the relationship between throttle position,changes in oil pressure and cycle power in the up- shift process is analyzed. The solutions to suppress the cycle power is proposed. A PID method is used to adjust the engine speed by controlling the throttle position. On the basis of disengage clutch and engage clutch,using the fuzzy control theory,taking the driver intention,the deviation of engine speed and target speed as inputs and taking the rise rate of oil- filled pressure as outputs,the up- shift control strategy is designed. It is concluded that the strategy can reduce cycle power effectively and shorten slip energy,jerk. The shifting quality is optimized.
format Article
id doaj-art-43655d78959f4d80ac7af0d9f4b802d6
institution Kabale University
issn 1004-2539
language zho
publishDate 2016-01-01
publisher Editorial Office of Journal of Mechanical Transmission
record_format Article
series Jixie chuandong
spelling doaj-art-43655d78959f4d80ac7af0d9f4b802d62025-01-10T14:15:13ZzhoEditorial Office of Journal of Mechanical TransmissionJixie chuandong1004-25392016-01-0140546329926376Study on The Method of Suppressing Cycle Power during Up-shift Process for Wet Dual Clutch TransmissionQu SiyuChen ManLiu JikaiGao SongThe cycle power,which is prone to appear during shifting process for a wet dual clutch transmission,the life of the clutch is severely affected and the shifting quality is decreased. In response to this phenomenon,the up- shift dynamics equations are derived according to the detailed analysis of up- shifts and the study on the cause of cycle power,during up- shift process of a DCT. Furthermore,the relationship between throttle position,changes in oil pressure and cycle power in the up- shift process is analyzed. The solutions to suppress the cycle power is proposed. A PID method is used to adjust the engine speed by controlling the throttle position. On the basis of disengage clutch and engage clutch,using the fuzzy control theory,taking the driver intention,the deviation of engine speed and target speed as inputs and taking the rise rate of oil- filled pressure as outputs,the up- shift control strategy is designed. It is concluded that the strategy can reduce cycle power effectively and shorten slip energy,jerk. The shifting quality is optimized.http://www.jxcd.net.cn/thesisDetails#10.16578/j.issn.1004.2539.2016.10.011Wet dual clutch transmissionUp-shift control strategyCycle powerFuzzy control
spellingShingle Qu Siyu
Chen Man
Liu Jikai
Gao Song
Study on The Method of Suppressing Cycle Power during Up-shift Process for Wet Dual Clutch Transmission
Jixie chuandong
Wet dual clutch transmission
Up-shift control strategy
Cycle power
Fuzzy control
title Study on The Method of Suppressing Cycle Power during Up-shift Process for Wet Dual Clutch Transmission
title_full Study on The Method of Suppressing Cycle Power during Up-shift Process for Wet Dual Clutch Transmission
title_fullStr Study on The Method of Suppressing Cycle Power during Up-shift Process for Wet Dual Clutch Transmission
title_full_unstemmed Study on The Method of Suppressing Cycle Power during Up-shift Process for Wet Dual Clutch Transmission
title_short Study on The Method of Suppressing Cycle Power during Up-shift Process for Wet Dual Clutch Transmission
title_sort study on the method of suppressing cycle power during up shift process for wet dual clutch transmission
topic Wet dual clutch transmission
Up-shift control strategy
Cycle power
Fuzzy control
url http://www.jxcd.net.cn/thesisDetails#10.16578/j.issn.1004.2539.2016.10.011
work_keys_str_mv AT qusiyu studyonthemethodofsuppressingcyclepowerduringupshiftprocessforwetdualclutchtransmission
AT chenman studyonthemethodofsuppressingcyclepowerduringupshiftprocessforwetdualclutchtransmission
AT liujikai studyonthemethodofsuppressingcyclepowerduringupshiftprocessforwetdualclutchtransmission
AT gaosong studyonthemethodofsuppressingcyclepowerduringupshiftprocessforwetdualclutchtransmission