Equalizing the response of the FOOT calorimeter as a function of the ion energy and charge

The precision of clinical treatment planning systems for particle therapy is limited (among other reasons) by the absence of measurements on the differential fragmentation cross sections generated during interactions between light ions (such as C and O) and hydrogen-enriched targets. To address this...

Full description

Saved in:
Bibliographic Details
Main Author: Valetti Alessandro
Format: Article
Language:English
Published: EDP Sciences 2025-01-01
Series:EPJ Web of Conferences
Online Access:https://www.epj-conferences.org/articles/epjconf/pdf/2025/05/epjconf_calor2024_00007.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849762397893427200
author Valetti Alessandro
author_facet Valetti Alessandro
author_sort Valetti Alessandro
collection DOAJ
description The precision of clinical treatment planning systems for particle therapy is limited (among other reasons) by the absence of measurements on the differential fragmentation cross sections generated during interactions between light ions (such as C and O) and hydrogen-enriched targets. To address this issue, the FOOT experiment has been designed to take data for beam energies up to 400 MeV/u using an inverse kinematics approach. By extending the energy range to 800 MeV/u, FOOT will also collect valuable data to optimize the design of spacecraft shielding [1]. The experiment aims at identifying fragments by measuring their momentum, kinetic energy, and time of flight with high resolution: 5%, 2% and <100 ps respectively. A calorimeter detector made of 320 BGO crystals coupled to SiPM photodetectors, covering a dynamic range from tens of MeVs to about 10 GeV, measures the kinetic energy. A series of data taking campaigns aiming at characterizing, optimizing and equalizing the crystals response have been conducted at HIT (Heidelberg, Germany) and CNAO (Pavia, Italy). The measurements confirm an integral energy resolution well below the goal of 2%. The modified Birks-energy-response-function shows an excellent agreement with the response of the crystals between 50 and 430 MeV/u for all the ions, although a dependence of the parameters on Z is observed. In this work, the equalization strategy needed to properly measure the fragments kinetic energy and masses in combination with the ToF detectors will be presented.
format Article
id doaj-art-418482e7a0974be287395714ffd92e2c
institution DOAJ
issn 2100-014X
language English
publishDate 2025-01-01
publisher EDP Sciences
record_format Article
series EPJ Web of Conferences
spelling doaj-art-418482e7a0974be287395714ffd92e2c2025-08-20T03:05:45ZengEDP SciencesEPJ Web of Conferences2100-014X2025-01-013200000710.1051/epjconf/202532000007epjconf_calor2024_00007Equalizing the response of the FOOT calorimeter as a function of the ion energy and chargeValetti Alessandro0University of Torino, Department of PhysicsThe precision of clinical treatment planning systems for particle therapy is limited (among other reasons) by the absence of measurements on the differential fragmentation cross sections generated during interactions between light ions (such as C and O) and hydrogen-enriched targets. To address this issue, the FOOT experiment has been designed to take data for beam energies up to 400 MeV/u using an inverse kinematics approach. By extending the energy range to 800 MeV/u, FOOT will also collect valuable data to optimize the design of spacecraft shielding [1]. The experiment aims at identifying fragments by measuring their momentum, kinetic energy, and time of flight with high resolution: 5%, 2% and <100 ps respectively. A calorimeter detector made of 320 BGO crystals coupled to SiPM photodetectors, covering a dynamic range from tens of MeVs to about 10 GeV, measures the kinetic energy. A series of data taking campaigns aiming at characterizing, optimizing and equalizing the crystals response have been conducted at HIT (Heidelberg, Germany) and CNAO (Pavia, Italy). The measurements confirm an integral energy resolution well below the goal of 2%. The modified Birks-energy-response-function shows an excellent agreement with the response of the crystals between 50 and 430 MeV/u for all the ions, although a dependence of the parameters on Z is observed. In this work, the equalization strategy needed to properly measure the fragments kinetic energy and masses in combination with the ToF detectors will be presented.https://www.epj-conferences.org/articles/epjconf/pdf/2025/05/epjconf_calor2024_00007.pdf
spellingShingle Valetti Alessandro
Equalizing the response of the FOOT calorimeter as a function of the ion energy and charge
EPJ Web of Conferences
title Equalizing the response of the FOOT calorimeter as a function of the ion energy and charge
title_full Equalizing the response of the FOOT calorimeter as a function of the ion energy and charge
title_fullStr Equalizing the response of the FOOT calorimeter as a function of the ion energy and charge
title_full_unstemmed Equalizing the response of the FOOT calorimeter as a function of the ion energy and charge
title_short Equalizing the response of the FOOT calorimeter as a function of the ion energy and charge
title_sort equalizing the response of the foot calorimeter as a function of the ion energy and charge
url https://www.epj-conferences.org/articles/epjconf/pdf/2025/05/epjconf_calor2024_00007.pdf
work_keys_str_mv AT valettialessandro equalizingtheresponseofthefootcalorimeterasafunctionoftheionenergyandcharge