Coordinate-sensitive charged particle detector for spectroscopy

The authors have designed, manufactured and tested a coordinate-sensitive detector for charged particle spectroscopy. The detector can be used in the devices for the elemental analysis of materials, providing simultaneous analysis of all the elemental composition with high sensitivity and precision....

Full description

Saved in:
Bibliographic Details
Main Authors: В. П. Сидоренко, Ю. В. Прокофьев, Д. С. Мурченко, B. M. Еременко, A. B. Шелехов
Format: Article
Language:English
Published: Politehperiodika 2016-10-01
Series:Tekhnologiya i Konstruirovanie v Elektronnoi Apparature
Subjects:
Online Access:https://tkea.com.ua/index.php/journal/article/view/237
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850280742216531968
author В. П. Сидоренко
Ю. В. Прокофьев
Д. С. Мурченко
B. M. Еременко
A. B. Шелехов
author_facet В. П. Сидоренко
Ю. В. Прокофьев
Д. С. Мурченко
B. M. Еременко
A. B. Шелехов
author_sort В. П. Сидоренко
collection DOAJ
description The authors have designed, manufactured and tested a coordinate-sensitive detector for charged particle spectroscopy. The detector can be used in the devices for the elemental analysis of materials, providing simultaneous analysis of all the elemental composition with high sensitivity and precision. The designed device is based on an integrated circuit (IC) and a microchannel plate (MCP) electron multiplier. The IC is mounted on a ceramic substrate. Ions fall on the MCP mounted above the IC. Giving rise to a pulse which typically exceeds 106 electrons, each ion falls on the detector electrodes and these pulses are counted. In this research, a two stage stack of MCPs (Hamamatsu) was used. The MCPs have a channel diameter of 12 μm on a 15 μm pitch. The results of tests carried out in a mass spectrometer are presented. The designed detector is small, light, and low-power.
format Article
id doaj-art-3eda0683ab284a9492e47faa714d1b44
institution OA Journals
issn 2225-5818
2309-9992
language English
publishDate 2016-10-01
publisher Politehperiodika
record_format Article
series Tekhnologiya i Konstruirovanie v Elektronnoi Apparature
spelling doaj-art-3eda0683ab284a9492e47faa714d1b442025-08-20T01:48:37ZengPolitehperiodikaTekhnologiya i Konstruirovanie v Elektronnoi Apparature2225-58182309-99922016-10-014–5536010.15222/TKEA2016.4-5.53237Coordinate-sensitive charged particle detector for spectroscopyВ. П. Сидоренко0Ю. В. Прокофьев1Д. С. Мурченко2B. M. Еременко3A. B. Шелехов4Institute of Microdevices of NAS of Ukraine, Kyiv, UkraineInstitute of Microdevices of NAS of Ukraine, Kyiv, UkraineInstitute of Microdevices of NAS of Ukraine, Kyiv, UkraineInstitute of Applied Physics of NAS of Ukraine, Sumy, UkraineInstitute of Applied Physics of NAS of Ukraine, Sumy, UkraineThe authors have designed, manufactured and tested a coordinate-sensitive detector for charged particle spectroscopy. The detector can be used in the devices for the elemental analysis of materials, providing simultaneous analysis of all the elemental composition with high sensitivity and precision. The designed device is based on an integrated circuit (IC) and a microchannel plate (MCP) electron multiplier. The IC is mounted on a ceramic substrate. Ions fall on the MCP mounted above the IC. Giving rise to a pulse which typically exceeds 106 electrons, each ion falls on the detector electrodes and these pulses are counted. In this research, a two stage stack of MCPs (Hamamatsu) was used. The MCPs have a channel diameter of 12 μm on a 15 μm pitch. The results of tests carried out in a mass spectrometer are presented. The designed detector is small, light, and low-power.https://tkea.com.ua/index.php/journal/article/view/237coordinate-sensitive detectorspectroscopyelemental analysismaterial compositionlarge scale integrated circuitmicrochannel plate
spellingShingle В. П. Сидоренко
Ю. В. Прокофьев
Д. С. Мурченко
B. M. Еременко
A. B. Шелехов
Coordinate-sensitive charged particle detector for spectroscopy
Tekhnologiya i Konstruirovanie v Elektronnoi Apparature
coordinate-sensitive detector
spectroscopy
elemental analysis
material composition
large scale integrated circuit
microchannel plate
title Coordinate-sensitive charged particle detector for spectroscopy
title_full Coordinate-sensitive charged particle detector for spectroscopy
title_fullStr Coordinate-sensitive charged particle detector for spectroscopy
title_full_unstemmed Coordinate-sensitive charged particle detector for spectroscopy
title_short Coordinate-sensitive charged particle detector for spectroscopy
title_sort coordinate sensitive charged particle detector for spectroscopy
topic coordinate-sensitive detector
spectroscopy
elemental analysis
material composition
large scale integrated circuit
microchannel plate
url https://tkea.com.ua/index.php/journal/article/view/237
work_keys_str_mv AT vpsidorenko coordinatesensitivechargedparticledetectorforspectroscopy
AT ûvprokofʹev coordinatesensitivechargedparticledetectorforspectroscopy
AT dsmurčenko coordinatesensitivechargedparticledetectorforspectroscopy
AT bmeremenko coordinatesensitivechargedparticledetectorforspectroscopy
AT abšelehov coordinatesensitivechargedparticledetectorforspectroscopy