Coordinate-sensitive charged particle detector for spectroscopy
The authors have designed, manufactured and tested a coordinate-sensitive detector for charged particle spectroscopy. The detector can be used in the devices for the elemental analysis of materials, providing simultaneous analysis of all the elemental composition with high sensitivity and precision....
Saved in:
| Main Authors: | , , , , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Politehperiodika
2016-10-01
|
| Series: | Tekhnologiya i Konstruirovanie v Elektronnoi Apparature |
| Subjects: | |
| Online Access: | https://tkea.com.ua/index.php/journal/article/view/237 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1850280742216531968 |
|---|---|
| author | В. П. Сидоренко Ю. В. Прокофьев Д. С. Мурченко B. M. Еременко A. B. Шелехов |
| author_facet | В. П. Сидоренко Ю. В. Прокофьев Д. С. Мурченко B. M. Еременко A. B. Шелехов |
| author_sort | В. П. Сидоренко |
| collection | DOAJ |
| description | The authors have designed, manufactured and tested a coordinate-sensitive detector for charged particle spectroscopy. The detector can be used in the devices for the elemental analysis of materials, providing simultaneous analysis of all the elemental composition with high sensitivity and precision. The designed device is based on an integrated circuit (IC) and a microchannel plate (MCP) electron multiplier. The IC is mounted on a ceramic substrate. Ions fall on the MCP mounted above the IC. Giving rise to a pulse which typically exceeds 106 electrons, each ion falls on the detector electrodes and these pulses are counted. In this research, a two stage stack of MCPs (Hamamatsu) was used. The MCPs have a channel diameter of 12 μm on a 15 μm pitch. The results of tests carried out in a mass spectrometer are presented. The designed detector is small, light, and low-power. |
| format | Article |
| id | doaj-art-3eda0683ab284a9492e47faa714d1b44 |
| institution | OA Journals |
| issn | 2225-5818 2309-9992 |
| language | English |
| publishDate | 2016-10-01 |
| publisher | Politehperiodika |
| record_format | Article |
| series | Tekhnologiya i Konstruirovanie v Elektronnoi Apparature |
| spelling | doaj-art-3eda0683ab284a9492e47faa714d1b442025-08-20T01:48:37ZengPolitehperiodikaTekhnologiya i Konstruirovanie v Elektronnoi Apparature2225-58182309-99922016-10-014–5536010.15222/TKEA2016.4-5.53237Coordinate-sensitive charged particle detector for spectroscopyВ. П. Сидоренко0Ю. В. Прокофьев1Д. С. Мурченко2B. M. Еременко3A. B. Шелехов4Institute of Microdevices of NAS of Ukraine, Kyiv, UkraineInstitute of Microdevices of NAS of Ukraine, Kyiv, UkraineInstitute of Microdevices of NAS of Ukraine, Kyiv, UkraineInstitute of Applied Physics of NAS of Ukraine, Sumy, UkraineInstitute of Applied Physics of NAS of Ukraine, Sumy, UkraineThe authors have designed, manufactured and tested a coordinate-sensitive detector for charged particle spectroscopy. The detector can be used in the devices for the elemental analysis of materials, providing simultaneous analysis of all the elemental composition with high sensitivity and precision. The designed device is based on an integrated circuit (IC) and a microchannel plate (MCP) electron multiplier. The IC is mounted on a ceramic substrate. Ions fall on the MCP mounted above the IC. Giving rise to a pulse which typically exceeds 106 electrons, each ion falls on the detector electrodes and these pulses are counted. In this research, a two stage stack of MCPs (Hamamatsu) was used. The MCPs have a channel diameter of 12 μm on a 15 μm pitch. The results of tests carried out in a mass spectrometer are presented. The designed detector is small, light, and low-power.https://tkea.com.ua/index.php/journal/article/view/237coordinate-sensitive detectorspectroscopyelemental analysismaterial compositionlarge scale integrated circuitmicrochannel plate |
| spellingShingle | В. П. Сидоренко Ю. В. Прокофьев Д. С. Мурченко B. M. Еременко A. B. Шелехов Coordinate-sensitive charged particle detector for spectroscopy Tekhnologiya i Konstruirovanie v Elektronnoi Apparature coordinate-sensitive detector spectroscopy elemental analysis material composition large scale integrated circuit microchannel plate |
| title | Coordinate-sensitive charged particle detector for spectroscopy |
| title_full | Coordinate-sensitive charged particle detector for spectroscopy |
| title_fullStr | Coordinate-sensitive charged particle detector for spectroscopy |
| title_full_unstemmed | Coordinate-sensitive charged particle detector for spectroscopy |
| title_short | Coordinate-sensitive charged particle detector for spectroscopy |
| title_sort | coordinate sensitive charged particle detector for spectroscopy |
| topic | coordinate-sensitive detector spectroscopy elemental analysis material composition large scale integrated circuit microchannel plate |
| url | https://tkea.com.ua/index.php/journal/article/view/237 |
| work_keys_str_mv | AT vpsidorenko coordinatesensitivechargedparticledetectorforspectroscopy AT ûvprokofʹev coordinatesensitivechargedparticledetectorforspectroscopy AT dsmurčenko coordinatesensitivechargedparticledetectorforspectroscopy AT bmeremenko coordinatesensitivechargedparticledetectorforspectroscopy AT abšelehov coordinatesensitivechargedparticledetectorforspectroscopy |