A System Assessment Method for Voltage Sag Severity Based on Average Point-To-Line Distance Index

In order to systematically compare the voltage sag severity of different regions, a system method is proposed to assess grid voltage sag severity. The method obtains the time duration intervals through cluster analysis, and gets the medians of residual voltages for different duration intervals, with...

Full description

Saved in:
Bibliographic Details
Main Authors: Qing ZHONG, Weilin YAO, Zhong XU, Kai ZHOU, Gang WANG
Format: Article
Language:zho
Published: State Grid Energy Research Institute 2020-11-01
Series:Zhongguo dianli
Subjects:
Online Access:https://www.electricpower.com.cn/CN/10.11930/j.issn.1004-9649.202006095
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850052733097213952
author Qing ZHONG
Weilin YAO
Zhong XU
Kai ZHOU
Gang WANG
author_facet Qing ZHONG
Weilin YAO
Zhong XU
Kai ZHOU
Gang WANG
author_sort Qing ZHONG
collection DOAJ
description In order to systematically compare the voltage sag severity of different regions, a system method is proposed to assess grid voltage sag severity. The method obtains the time duration intervals through cluster analysis, and gets the medians of residual voltages for different duration intervals, with which the median line is plotted. And then, the average point-to-line distance index is proposed to quantify the voltage sag severity for different regions. The voltage sag levels are graded according to index distribution features of different regions. The correctness and feasibility of the proposed assessment method are verified with the real monitoring data of a city power system. This method can effectively obtain from numerous monitoring data the voltage sag severity information of different regions, and realize the system assessment of the voltage sags from two dimensions: residual voltage and time duration, which is conducive to compare the voltage sag severity among different regions.
format Article
id doaj-art-3e7daaf1e5054140b0a36a3441eb7964
institution DOAJ
issn 1004-9649
language zho
publishDate 2020-11-01
publisher State Grid Energy Research Institute
record_format Article
series Zhongguo dianli
spelling doaj-art-3e7daaf1e5054140b0a36a3441eb79642025-08-20T02:52:44ZzhoState Grid Energy Research InstituteZhongguo dianli1004-96492020-11-01531191410.11930/j.issn.1004-9649.202006095zgdl-53-11-zhongqingA System Assessment Method for Voltage Sag Severity Based on Average Point-To-Line Distance IndexQing ZHONG0Weilin YAO1Zhong XU2Kai ZHOU3Gang WANG4School of Electric Power, South China University of Technology, Guangzhou 510641, ChinaSchool of Electric Power, South China University of Technology, Guangzhou 510641, ChinaGuangzhou Power Supply Bureau Co. Ltd., Guangzhou 510600, ChinaGuangzhou Power Supply Bureau Co. Ltd., Guangzhou 510600, ChinaSchool of Electric Power, South China University of Technology, Guangzhou 510641, ChinaIn order to systematically compare the voltage sag severity of different regions, a system method is proposed to assess grid voltage sag severity. The method obtains the time duration intervals through cluster analysis, and gets the medians of residual voltages for different duration intervals, with which the median line is plotted. And then, the average point-to-line distance index is proposed to quantify the voltage sag severity for different regions. The voltage sag levels are graded according to index distribution features of different regions. The correctness and feasibility of the proposed assessment method are verified with the real monitoring data of a city power system. This method can effectively obtain from numerous monitoring data the voltage sag severity information of different regions, and realize the system assessment of the voltage sags from two dimensions: residual voltage and time duration, which is conducive to compare the voltage sag severity among different regions.https://www.electricpower.com.cn/CN/10.11930/j.issn.1004-9649.202006095power qualityvoltage sagsystem assessmentpoint-to-line distance
spellingShingle Qing ZHONG
Weilin YAO
Zhong XU
Kai ZHOU
Gang WANG
A System Assessment Method for Voltage Sag Severity Based on Average Point-To-Line Distance Index
Zhongguo dianli
power quality
voltage sag
system assessment
point-to-line distance
title A System Assessment Method for Voltage Sag Severity Based on Average Point-To-Line Distance Index
title_full A System Assessment Method for Voltage Sag Severity Based on Average Point-To-Line Distance Index
title_fullStr A System Assessment Method for Voltage Sag Severity Based on Average Point-To-Line Distance Index
title_full_unstemmed A System Assessment Method for Voltage Sag Severity Based on Average Point-To-Line Distance Index
title_short A System Assessment Method for Voltage Sag Severity Based on Average Point-To-Line Distance Index
title_sort system assessment method for voltage sag severity based on average point to line distance index
topic power quality
voltage sag
system assessment
point-to-line distance
url https://www.electricpower.com.cn/CN/10.11930/j.issn.1004-9649.202006095
work_keys_str_mv AT qingzhong asystemassessmentmethodforvoltagesagseveritybasedonaveragepointtolinedistanceindex
AT weilinyao asystemassessmentmethodforvoltagesagseveritybasedonaveragepointtolinedistanceindex
AT zhongxu asystemassessmentmethodforvoltagesagseveritybasedonaveragepointtolinedistanceindex
AT kaizhou asystemassessmentmethodforvoltagesagseveritybasedonaveragepointtolinedistanceindex
AT gangwang asystemassessmentmethodforvoltagesagseveritybasedonaveragepointtolinedistanceindex
AT qingzhong systemassessmentmethodforvoltagesagseveritybasedonaveragepointtolinedistanceindex
AT weilinyao systemassessmentmethodforvoltagesagseveritybasedonaveragepointtolinedistanceindex
AT zhongxu systemassessmentmethodforvoltagesagseveritybasedonaveragepointtolinedistanceindex
AT kaizhou systemassessmentmethodforvoltagesagseveritybasedonaveragepointtolinedistanceindex
AT gangwang systemassessmentmethodforvoltagesagseveritybasedonaveragepointtolinedistanceindex