Transcranial Doppler as a Primary Screening Tool for Detecting Right‐to‐Left Shunt in Cryptogenic Stroke Patients?

ABSTRACT Background Cryptogenic stroke (CS), a subtype of ischemic stroke with undetermined etiology, accounts for approximately 25% of the cases. Patent foramen ovale (PFO) is an important potential cause of CS via paradoxical embolism. While transesophageal echocardiography (TEE) is the current go...

Full description

Saved in:
Bibliographic Details
Main Authors: Payam Sasannejad, Fateme Khosravani, Alireza Ziaei Moghaddam, Mohsen Soltani Sabi, Lida Jarahi
Format: Article
Language:English
Published: Wiley 2024-11-01
Series:Brain and Behavior
Online Access:https://doi.org/10.1002/brb3.70144
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850220332699353088
author Payam Sasannejad
Fateme Khosravani
Alireza Ziaei Moghaddam
Mohsen Soltani Sabi
Lida Jarahi
author_facet Payam Sasannejad
Fateme Khosravani
Alireza Ziaei Moghaddam
Mohsen Soltani Sabi
Lida Jarahi
author_sort Payam Sasannejad
collection DOAJ
description ABSTRACT Background Cryptogenic stroke (CS), a subtype of ischemic stroke with undetermined etiology, accounts for approximately 25% of the cases. Patent foramen ovale (PFO) is an important potential cause of CS via paradoxical embolism. While transesophageal echocardiography (TEE) is the current gold standard for PFO detection, transcranial Doppler (TCD) ultrasound offers a noninvasive alternative with potential advantages in sensitivity for right‐to‐left shunt (RLS) detection. This study's main goal is to evaluate the diagnostic performance of TCD compared to TEE for PFO detection in CS patients. Methods We prospectively enrolled 110 patients aged 18–65 years with confirmed CS from 2020 to 2024. All underwent TCD screening for RLS using a standardized protocol. Subsequently, they were categorized based on a simplified version of the Spencer Logarithmic Scale, followed by confirmatory TEE. Clinical characteristics, imaging findings, TCD results, and indications for PFO closure were analyzed. Results The mean age of the cohort was 45 years, with 58.2% being males. TEE identified PFO in 44.5% (49/110) of subjects. TCD accurately detected RLS in 42 of the 49 PFO cases (85.7%) confirmed by TEE. For PFO detection, TCD demonstrated a sensitivity of 85.4%, specificity of 88.5%, PPV of 85.4%, and Youden's index of 0.73. Notably, of the seven PFO cases missed by TCD, none received percutaneous closure based on clinical criteria. Conclusions TCD exhibited high diagnostic accuracy for detecting high‐risk PFO in patients with CS when compared to the gold‐standard TEE. As a noninvasive modality, TCD may serve as an effective screening tool to identify CS patients who could potentially benefit from confirmatory TEE and subsequent PFO closure intervention. The findings support the use of TCD as a screening tool to triage CS patients for confirmatory TEE and potential PFO closure.
format Article
id doaj-art-3e642b08c81e479199f4c60dd9c2cfa9
institution OA Journals
issn 2162-3279
language English
publishDate 2024-11-01
publisher Wiley
record_format Article
series Brain and Behavior
spelling doaj-art-3e642b08c81e479199f4c60dd9c2cfa92025-08-20T02:07:06ZengWileyBrain and Behavior2162-32792024-11-011411n/an/a10.1002/brb3.70144Transcranial Doppler as a Primary Screening Tool for Detecting Right‐to‐Left Shunt in Cryptogenic Stroke Patients?Payam Sasannejad0Fateme Khosravani1Alireza Ziaei Moghaddam2Mohsen Soltani Sabi3Lida Jarahi4Department of Neurology, Faculty of MedicineMashhad University of Medical SciencesMashhadIranDepartment of Neurology, Faculty of MedicineMashhad University of Medical SciencesMashhadIranStudent Research Committee, Faculty of MedicineMashhad University of Medical SciencesMashhad IranDepartment of Neurology, Faculty of MedicineMashhad University of Medical SciencesMashhadIranDepartment of Community Medicine, Faculty of MedicineMashhad University of Medical SciencesMashhadIranABSTRACT Background Cryptogenic stroke (CS), a subtype of ischemic stroke with undetermined etiology, accounts for approximately 25% of the cases. Patent foramen ovale (PFO) is an important potential cause of CS via paradoxical embolism. While transesophageal echocardiography (TEE) is the current gold standard for PFO detection, transcranial Doppler (TCD) ultrasound offers a noninvasive alternative with potential advantages in sensitivity for right‐to‐left shunt (RLS) detection. This study's main goal is to evaluate the diagnostic performance of TCD compared to TEE for PFO detection in CS patients. Methods We prospectively enrolled 110 patients aged 18–65 years with confirmed CS from 2020 to 2024. All underwent TCD screening for RLS using a standardized protocol. Subsequently, they were categorized based on a simplified version of the Spencer Logarithmic Scale, followed by confirmatory TEE. Clinical characteristics, imaging findings, TCD results, and indications for PFO closure were analyzed. Results The mean age of the cohort was 45 years, with 58.2% being males. TEE identified PFO in 44.5% (49/110) of subjects. TCD accurately detected RLS in 42 of the 49 PFO cases (85.7%) confirmed by TEE. For PFO detection, TCD demonstrated a sensitivity of 85.4%, specificity of 88.5%, PPV of 85.4%, and Youden's index of 0.73. Notably, of the seven PFO cases missed by TCD, none received percutaneous closure based on clinical criteria. Conclusions TCD exhibited high diagnostic accuracy for detecting high‐risk PFO in patients with CS when compared to the gold‐standard TEE. As a noninvasive modality, TCD may serve as an effective screening tool to identify CS patients who could potentially benefit from confirmatory TEE and subsequent PFO closure intervention. The findings support the use of TCD as a screening tool to triage CS patients for confirmatory TEE and potential PFO closure.https://doi.org/10.1002/brb3.70144
spellingShingle Payam Sasannejad
Fateme Khosravani
Alireza Ziaei Moghaddam
Mohsen Soltani Sabi
Lida Jarahi
Transcranial Doppler as a Primary Screening Tool for Detecting Right‐to‐Left Shunt in Cryptogenic Stroke Patients?
Brain and Behavior
title Transcranial Doppler as a Primary Screening Tool for Detecting Right‐to‐Left Shunt in Cryptogenic Stroke Patients?
title_full Transcranial Doppler as a Primary Screening Tool for Detecting Right‐to‐Left Shunt in Cryptogenic Stroke Patients?
title_fullStr Transcranial Doppler as a Primary Screening Tool for Detecting Right‐to‐Left Shunt in Cryptogenic Stroke Patients?
title_full_unstemmed Transcranial Doppler as a Primary Screening Tool for Detecting Right‐to‐Left Shunt in Cryptogenic Stroke Patients?
title_short Transcranial Doppler as a Primary Screening Tool for Detecting Right‐to‐Left Shunt in Cryptogenic Stroke Patients?
title_sort transcranial doppler as a primary screening tool for detecting right to left shunt in cryptogenic stroke patients
url https://doi.org/10.1002/brb3.70144
work_keys_str_mv AT payamsasannejad transcranialdopplerasaprimaryscreeningtoolfordetectingrighttoleftshuntincryptogenicstrokepatients
AT fatemekhosravani transcranialdopplerasaprimaryscreeningtoolfordetectingrighttoleftshuntincryptogenicstrokepatients
AT alirezaziaeimoghaddam transcranialdopplerasaprimaryscreeningtoolfordetectingrighttoleftshuntincryptogenicstrokepatients
AT mohsensoltanisabi transcranialdopplerasaprimaryscreeningtoolfordetectingrighttoleftshuntincryptogenicstrokepatients
AT lidajarahi transcranialdopplerasaprimaryscreeningtoolfordetectingrighttoleftshuntincryptogenicstrokepatients