Research on Data-driven PET-CT Gating Imaging Method

PET-CT is a multimodal imaging technology that organically combines positron emission tomography (PET) and computed tomography (CT), providing accurate and comprehensive functional imaging and structural information imaging simultaneously. During the imaging of the thorax and heart in vivo, motion b...

Full description

Saved in:
Bibliographic Details
Main Author: XU Shidong1, 2, 3, 4, SUN Xiaoli1, 3, 4, , LIU Shuangquan1, 3, 4, ZHENG Yushuang1, 3, 4, LI Mohan1, 3, 4, WEI Cunfeng1, 2, 3, 4
Format: Article
Language:English
Published: Editorial Board of Atomic Energy Science and Technology 2025-06-01
Series:Yuanzineng kexue jishu
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849410063789195264
author XU Shidong1, 2, 3, 4, SUN Xiaoli1, 3, 4, , LIU Shuangquan1, 3, 4, ZHENG Yushuang1, 3, 4, LI Mohan1, 3, 4, WEI Cunfeng1, 2, 3, 4
author_facet XU Shidong1, 2, 3, 4, SUN Xiaoli1, 3, 4, , LIU Shuangquan1, 3, 4, ZHENG Yushuang1, 3, 4, LI Mohan1, 3, 4, WEI Cunfeng1, 2, 3, 4
author_sort XU Shidong1, 2, 3, 4, SUN Xiaoli1, 3, 4, , LIU Shuangquan1, 3, 4, ZHENG Yushuang1, 3, 4, LI Mohan1, 3, 4, WEI Cunfeng1, 2, 3, 4
collection DOAJ
description PET-CT is a multimodal imaging technology that organically combines positron emission tomography (PET) and computed tomography (CT), providing accurate and comprehensive functional imaging and structural information imaging simultaneously. During the imaging of the thorax and heart in vivo, motion blur caused by unavoidable respiratory and cardiac movements severely interferes with quantitative analysis, thus affecting the accuracy of diagnostic results. At the same time, in other applications, the different motion states are of interest, for instance in cardiac studies to find the ejection fraction and wall motion, or in radio-therapy. In response to the issues and needs above, gated imaging methods have been proposed. Gated imaging involves several steps. First, gated signal acquisition is performed. Next, the PET and CT data are grouped based on predefined gated groups. Finally, attenuation correction and reconstruction of PET data are carried out using the grouped CT data. Each step in these first three processes can significantly impact the final imaging results. Early gated signal acquisition relied on external devices. For example, airbags used for collecting respiratory signals and ECG patches used for collecting cardiac signals, which introduced problems such as operational complexity, high costs, reduced patient comfort, and difficulties in accurately correlating the acquired signals with PET and CT data. Currently, commonly used gated imaging techniques address the artifacts caused by respiratory and cardiac motion primarily through external gating devices and data-driven methods. However, existing data-driven gating methods have trouble balancing stable multimodal data processing, accurate cardiac signal extraction, and real-time operation with feedback capabilities. An improved data-driven gating method, partial data principal component analysis (PD-PCA), which optimizes the gating signal extraction approach and preprocesses the raw data was proposed. The combination of these two aspects further enhances the accuracy of gating signal extraction. In the PD-PCA method, the window width is determined based on the biological respiratory cycle, and PCA processing of the local temporal information is performed based on this window width. The PD-PCA method can process the acquired partial data during the data acquisition process, resulting in more accurate heartbeat signals, improves the accuracy of cardiac gating grouping. Additionally, the grouping method during the gated grouping phase for respiratory gating was also improved, using a histogram statistical method to accurately locate stable respiratory periods, and accounting for the biological respiratory characteristics. The methods can improve the accuracy of the classification of stable respiratory periods. The experimental results indicate that the improved gating imaging method ensures higher accuracy in cardiac signal extraction, enabling real-time gated dynamic high-precision imaging.
format Article
id doaj-art-3e44cb97465c45c48bc38f1c9dce1c5e
institution Kabale University
issn 1000-6931
language English
publishDate 2025-06-01
publisher Editorial Board of Atomic Energy Science and Technology
record_format Article
series Yuanzineng kexue jishu
spelling doaj-art-3e44cb97465c45c48bc38f1c9dce1c5e2025-08-20T03:35:16ZengEditorial Board of Atomic Energy Science and TechnologyYuanzineng kexue jishu1000-69312025-06-015961361137210.7538/yzk.2024.youxian.0814Research on Data-driven PET-CT Gating Imaging MethodXU Shidong1, 2, 3, 4, SUN Xiaoli1, 3, 4, , LIU Shuangquan1, 3, 4, ZHENG Yushuang1, 3, 4, LI Mohan1, 3, 4, WEI Cunfeng1, 2, 3, 401. Beijing Engineering Research Center of Radiographic Techniques and Equipment, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China 2. School of Nuclear Science and Technology, University of Chinese Academy of Sciences, Beijing 100049, China 3. Jinan Laboratory of Applied Nuclear Science, Jinan 250131, China 4. CAEA Center of Excellence on Nuclear Technology Applications for Nuclear Detection and Imaging, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, ChinaPET-CT is a multimodal imaging technology that organically combines positron emission tomography (PET) and computed tomography (CT), providing accurate and comprehensive functional imaging and structural information imaging simultaneously. During the imaging of the thorax and heart in vivo, motion blur caused by unavoidable respiratory and cardiac movements severely interferes with quantitative analysis, thus affecting the accuracy of diagnostic results. At the same time, in other applications, the different motion states are of interest, for instance in cardiac studies to find the ejection fraction and wall motion, or in radio-therapy. In response to the issues and needs above, gated imaging methods have been proposed. Gated imaging involves several steps. First, gated signal acquisition is performed. Next, the PET and CT data are grouped based on predefined gated groups. Finally, attenuation correction and reconstruction of PET data are carried out using the grouped CT data. Each step in these first three processes can significantly impact the final imaging results. Early gated signal acquisition relied on external devices. For example, airbags used for collecting respiratory signals and ECG patches used for collecting cardiac signals, which introduced problems such as operational complexity, high costs, reduced patient comfort, and difficulties in accurately correlating the acquired signals with PET and CT data. Currently, commonly used gated imaging techniques address the artifacts caused by respiratory and cardiac motion primarily through external gating devices and data-driven methods. However, existing data-driven gating methods have trouble balancing stable multimodal data processing, accurate cardiac signal extraction, and real-time operation with feedback capabilities. An improved data-driven gating method, partial data principal component analysis (PD-PCA), which optimizes the gating signal extraction approach and preprocesses the raw data was proposed. The combination of these two aspects further enhances the accuracy of gating signal extraction. In the PD-PCA method, the window width is determined based on the biological respiratory cycle, and PCA processing of the local temporal information is performed based on this window width. The PD-PCA method can process the acquired partial data during the data acquisition process, resulting in more accurate heartbeat signals, improves the accuracy of cardiac gating grouping. Additionally, the grouping method during the gated grouping phase for respiratory gating was also improved, using a histogram statistical method to accurately locate stable respiratory periods, and accounting for the biological respiratory characteristics. The methods can improve the accuracy of the classification of stable respiratory periods. The experimental results indicate that the improved gating imaging method ensures higher accuracy in cardiac signal extraction, enabling real-time gated dynamic high-precision imaging.gated imagingdata-drivenpet-ctpd-pca
spellingShingle XU Shidong1, 2, 3, 4, SUN Xiaoli1, 3, 4, , LIU Shuangquan1, 3, 4, ZHENG Yushuang1, 3, 4, LI Mohan1, 3, 4, WEI Cunfeng1, 2, 3, 4
Research on Data-driven PET-CT Gating Imaging Method
Yuanzineng kexue jishu
gated imaging
data-driven
pet-ct
pd-pca
title Research on Data-driven PET-CT Gating Imaging Method
title_full Research on Data-driven PET-CT Gating Imaging Method
title_fullStr Research on Data-driven PET-CT Gating Imaging Method
title_full_unstemmed Research on Data-driven PET-CT Gating Imaging Method
title_short Research on Data-driven PET-CT Gating Imaging Method
title_sort research on data driven pet ct gating imaging method
topic gated imaging
data-driven
pet-ct
pd-pca
work_keys_str_mv AT xushidong1234sunxiaoli134liushuangquan134zhengyushuang134limohan134weicunfeng1234 researchondatadrivenpetctgatingimagingmethod