Frequency-Adaptive Current Control of a Grid-Connected Inverter Based on Incomplete State Observation Under Severe Grid Conditions

Grid-connected inverter (GCI) plays a crucial role in facilitating stable and efficient power delivery, especially under severe and complex grid conditions. Harmonic distortions and imbalance of the grid voltages may degrade the grid-injected current quality. Moreover, inductive-capacitance (LC) gri...

Full description

Saved in:
Bibliographic Details
Main Authors: Min Kang, Sung-Dong Kim, Kyeong-Hwa Kim
Format: Article
Language:English
Published: MDPI AG 2025-04-01
Series:Energies
Subjects:
Online Access:https://www.mdpi.com/1996-1073/18/8/1879
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850183609107873792
author Min Kang
Sung-Dong Kim
Kyeong-Hwa Kim
author_facet Min Kang
Sung-Dong Kim
Kyeong-Hwa Kim
author_sort Min Kang
collection DOAJ
description Grid-connected inverter (GCI) plays a crucial role in facilitating stable and efficient power delivery, especially under severe and complex grid conditions. Harmonic distortions and imbalance of the grid voltages may degrade the grid-injected current quality. Moreover, inductive-capacitance (LC) grid impedance and the grid frequency fluctuation also degrade the current control performance or stability. In order to overcome such an issue, this study presents a frequency-adaptive current control strategy of a GCI based on incomplete state observation under severe grid conditions. When LC grid impedance exists, it introduces additional states in a GCI system model. However, since the state for the grid inductance current is unmeasurable, it yields a limitation in the state feedback control design. To overcome such a limitation, this study adopts a state feedback control approach based on incomplete state observation by designing the controller only with the available states. The proposed control strategy incorporates feedback controllers with ten states, an integral controller, and resonant controllers for the robustness of the inverter operation. To reduce the reliance on additional sensing devices, a discrete-time full-state current observer is utilized. Particularly, with the aim of avoiding the grid frequency dependency of the system model, as well as the complex online discretization process, observer design is developed in the stationary reference frame. Additionally, a moving average filter (MAF)-based phase-locked loop (PLL) is incorporated for accurate frequency detection against distortions of grid voltages. For evaluating the performance of the designed control strategy, simulations and experiments are executed with severe grid conditions, including grid frequency changes, unbalanced grid voltage, harmonic distortion, and LC grid impedance.
format Article
id doaj-art-3db0e4812f1648d48a349fb2af66c19e
institution OA Journals
issn 1996-1073
language English
publishDate 2025-04-01
publisher MDPI AG
record_format Article
series Energies
spelling doaj-art-3db0e4812f1648d48a349fb2af66c19e2025-08-20T02:17:19ZengMDPI AGEnergies1996-10732025-04-01188187910.3390/en18081879Frequency-Adaptive Current Control of a Grid-Connected Inverter Based on Incomplete State Observation Under Severe Grid ConditionsMin Kang0Sung-Dong Kim1Kyeong-Hwa Kim2Department of Electrical and Information Engineering, Seoul National University of Science and Technology, 232 Gongneung-ro, Nowon-gu, Seoul 01811, Republic of KoreaDepartment of Electrical and Information Engineering, Seoul National University of Science and Technology, 232 Gongneung-ro, Nowon-gu, Seoul 01811, Republic of KoreaDepartment of Electrical and Information Engineering, Seoul National University of Science and Technology, 232 Gongneung-ro, Nowon-gu, Seoul 01811, Republic of KoreaGrid-connected inverter (GCI) plays a crucial role in facilitating stable and efficient power delivery, especially under severe and complex grid conditions. Harmonic distortions and imbalance of the grid voltages may degrade the grid-injected current quality. Moreover, inductive-capacitance (LC) grid impedance and the grid frequency fluctuation also degrade the current control performance or stability. In order to overcome such an issue, this study presents a frequency-adaptive current control strategy of a GCI based on incomplete state observation under severe grid conditions. When LC grid impedance exists, it introduces additional states in a GCI system model. However, since the state for the grid inductance current is unmeasurable, it yields a limitation in the state feedback control design. To overcome such a limitation, this study adopts a state feedback control approach based on incomplete state observation by designing the controller only with the available states. The proposed control strategy incorporates feedback controllers with ten states, an integral controller, and resonant controllers for the robustness of the inverter operation. To reduce the reliance on additional sensing devices, a discrete-time full-state current observer is utilized. Particularly, with the aim of avoiding the grid frequency dependency of the system model, as well as the complex online discretization process, observer design is developed in the stationary reference frame. Additionally, a moving average filter (MAF)-based phase-locked loop (PLL) is incorporated for accurate frequency detection against distortions of grid voltages. For evaluating the performance of the designed control strategy, simulations and experiments are executed with severe grid conditions, including grid frequency changes, unbalanced grid voltage, harmonic distortion, and LC grid impedance.https://www.mdpi.com/1996-1073/18/8/1879frequency-adaptive current controlgrid-connected inverterharmonic distortionincomplete observationLC grid impedancesevere grid condition
spellingShingle Min Kang
Sung-Dong Kim
Kyeong-Hwa Kim
Frequency-Adaptive Current Control of a Grid-Connected Inverter Based on Incomplete State Observation Under Severe Grid Conditions
Energies
frequency-adaptive current control
grid-connected inverter
harmonic distortion
incomplete observation
LC grid impedance
severe grid condition
title Frequency-Adaptive Current Control of a Grid-Connected Inverter Based on Incomplete State Observation Under Severe Grid Conditions
title_full Frequency-Adaptive Current Control of a Grid-Connected Inverter Based on Incomplete State Observation Under Severe Grid Conditions
title_fullStr Frequency-Adaptive Current Control of a Grid-Connected Inverter Based on Incomplete State Observation Under Severe Grid Conditions
title_full_unstemmed Frequency-Adaptive Current Control of a Grid-Connected Inverter Based on Incomplete State Observation Under Severe Grid Conditions
title_short Frequency-Adaptive Current Control of a Grid-Connected Inverter Based on Incomplete State Observation Under Severe Grid Conditions
title_sort frequency adaptive current control of a grid connected inverter based on incomplete state observation under severe grid conditions
topic frequency-adaptive current control
grid-connected inverter
harmonic distortion
incomplete observation
LC grid impedance
severe grid condition
url https://www.mdpi.com/1996-1073/18/8/1879
work_keys_str_mv AT minkang frequencyadaptivecurrentcontrolofagridconnectedinverterbasedonincompletestateobservationunderseveregridconditions
AT sungdongkim frequencyadaptivecurrentcontrolofagridconnectedinverterbasedonincompletestateobservationunderseveregridconditions
AT kyeonghwakim frequencyadaptivecurrentcontrolofagridconnectedinverterbasedonincompletestateobservationunderseveregridconditions