Postoperative early weight-bearing using double plating for periprosthetic, interprosthetic, and interimplant distal femur fractures following total knee arthroplasty: A report of three cases

Background: Distal femur fractures (DFFs) following total knee arthroplasty (TKA) in older patients often require prolonged non-weight-bearing, thereby decreasing their activities of daily living (ADL) and increasing mortality. This report clarifies early weight-bearing safety and utility by using d...

Full description

Saved in:
Bibliographic Details
Main Authors: Nobuyoshi Watanabe, Yoshiteru Kajikawa, Tadahiko Yotsumoto, Takuro Kanda, Ryosuke Ikeda, Genji Takehara, Yasushi Oshima, Kenji Takahashi, Yoshinobu Watanabe
Format: Article
Language:English
Published: Elsevier 2024-08-01
Series:Trauma Case Reports
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S235264402400092X
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Background: Distal femur fractures (DFFs) following total knee arthroplasty (TKA) in older patients often require prolonged non-weight-bearing, thereby decreasing their activities of daily living (ADL) and increasing mortality. This report clarifies early weight-bearing safety and utility by using double-plate fixation on medial and lateral sides (LM180 double-plate fixation) for DFFs following TKA. Case presentation: Three cases of Su Type III periprosthetic, interprosthetic, and interimplant DFFs following TKA, where bone stock was limited, were treated with LM180 double-plate fixation using locking plates through medial and lateral incisions on the distal femur. In interprosthetic and interimplant DFF cases, the proximal section was secured by overlapping the lateral plate +/− medial plate with the proximal femur stem of the intramedullary nail by using monocortical screws and cerclage wires. Early postoperative partial weight-bearing was recommended, and full weight-bearing was allowed 4–5 weeks postoperation. All cases regained independent walking without hardware failure. Average ADL scores, namely, Barthel index (BI) and functional independence measure (FIM), were recovered to 85/100 and 114.7/126, respectively, approaching near-normal values. Conclusion: LM180 double-plate fixation for DFFs such as Su Type III periprosthetic, Vancouver type C interprosthetic, and interimplant DFFs following TKA with limited bone stock can be used to achieve early weight-bearing without fixation failure and help maintain ADL.
ISSN:2352-6440