Estimation of effective dose for children in interventional cardiology

This study is devoted to the estimation of effective dose for children undergoing interventional cardiology examinations. The conversion coefficients (CC) from directly measured dose area product (DAP) value to effective dose (ED) were calculated within the approved effective dose assessment methodo...

Full description

Saved in:
Bibliographic Details
Main Author: S. S. Sarycheva
Format: Article
Language:English
Published: Saint-Petersburg Research Institute of Radiation Hygiene after Professor P.V. Ramzaev 2017-06-01
Series:Радиационная гигиена
Subjects:
Online Access:https://www.radhyg.ru/jour/article/view/505
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849774198258401280
author S. S. Sarycheva
author_facet S. S. Sarycheva
author_sort S. S. Sarycheva
collection DOAJ
description This study is devoted to the estimation of effective dose for children undergoing interventional cardiology examinations. The conversion coefficients (CC) from directly measured dose area product (DAP) value to effective dose (ED) were calculated within the approved effective dose assessment methodology (Guidelines 2.6.1. 2944-11). The CC, Ed K , [mSv / (Gy • cm2)] for newborn infants and children of 1, 5, 10 and 15 years old (main(range)) were calculated as 2.5 (1.8-3.2); 1.1 (0.8-1.3); 0.6 (0.4-0.7); 0.4 (0.3-0.5); and 0,22 (0,18-0,30) respectively. A special Finnish computer program PCXMC 2.0 was used for calculating the dose CC. The series of calculations were made for different values of the physical and geometrical parameters based on their real-existing range of values. The value of CC from DAP to ED were calculated for all pediatric age groups. This work included 153 pediatric interventional studies carried out in two hospitals of the city of St. Petersburg for the period of one year from the summer of 2015. The dose CC dependency from the patient’s age and parameters of the examinations were under the study. The dependence from the beam quality (filtration and tube voltage) and age of the patient were found. The younger is the patient, stronger is the filtration and higher is the voltage, the higher is the CC value. The CC in the younger (newborn) and older (15 years) age groups are different by the factor of 10. It was shown that the changes of the geometric parameters (in the scope of their real existing range) have small effect on the value of the effective dose, not exceed 30-50% allowable for radiation protection purpose. The real values of effective doses of children undergoing cardiac interventions were estimated. In severe cases, the values of ED can reach several tens of mSv.
format Article
id doaj-art-3cec13c4a6074546a936d781a7f63ea1
institution DOAJ
issn 1998-426X
language English
publishDate 2017-06-01
publisher Saint-Petersburg Research Institute of Radiation Hygiene after Professor P.V. Ramzaev
record_format Article
series Радиационная гигиена
spelling doaj-art-3cec13c4a6074546a936d781a7f63ea12025-08-20T03:01:49ZengSaint-Petersburg Research Institute of Radiation Hygiene after Professor P.V. RamzaevРадиационная гигиена1998-426X2017-06-01102162210.21514/1998-426X-2017-10-2-16-22490Estimation of effective dose for children in interventional cardiologyS. S. Sarycheva0Saint-Petersburg Research Institute of Radiation Hygiene after Professor P.V. Ramzaev, Federal Service for Surveillance on Consumer Rights Protection and Human Well-BeingThis study is devoted to the estimation of effective dose for children undergoing interventional cardiology examinations. The conversion coefficients (CC) from directly measured dose area product (DAP) value to effective dose (ED) were calculated within the approved effective dose assessment methodology (Guidelines 2.6.1. 2944-11). The CC, Ed K , [mSv / (Gy • cm2)] for newborn infants and children of 1, 5, 10 and 15 years old (main(range)) were calculated as 2.5 (1.8-3.2); 1.1 (0.8-1.3); 0.6 (0.4-0.7); 0.4 (0.3-0.5); and 0,22 (0,18-0,30) respectively. A special Finnish computer program PCXMC 2.0 was used for calculating the dose CC. The series of calculations were made for different values of the physical and geometrical parameters based on their real-existing range of values. The value of CC from DAP to ED were calculated for all pediatric age groups. This work included 153 pediatric interventional studies carried out in two hospitals of the city of St. Petersburg for the period of one year from the summer of 2015. The dose CC dependency from the patient’s age and parameters of the examinations were under the study. The dependence from the beam quality (filtration and tube voltage) and age of the patient were found. The younger is the patient, stronger is the filtration and higher is the voltage, the higher is the CC value. The CC in the younger (newborn) and older (15 years) age groups are different by the factor of 10. It was shown that the changes of the geometric parameters (in the scope of their real existing range) have small effect on the value of the effective dose, not exceed 30-50% allowable for radiation protection purpose. The real values of effective doses of children undergoing cardiac interventions were estimated. In severe cases, the values of ED can reach several tens of mSv.https://www.radhyg.ru/jour/article/view/505interventional cardiologyeffective dosepediatric patientprogram pcxmc 2.0
spellingShingle S. S. Sarycheva
Estimation of effective dose for children in interventional cardiology
Радиационная гигиена
interventional cardiology
effective dose
pediatric patient
program pcxmc 2.0
title Estimation of effective dose for children in interventional cardiology
title_full Estimation of effective dose for children in interventional cardiology
title_fullStr Estimation of effective dose for children in interventional cardiology
title_full_unstemmed Estimation of effective dose for children in interventional cardiology
title_short Estimation of effective dose for children in interventional cardiology
title_sort estimation of effective dose for children in interventional cardiology
topic interventional cardiology
effective dose
pediatric patient
program pcxmc 2.0
url https://www.radhyg.ru/jour/article/view/505
work_keys_str_mv AT sssarycheva estimationofeffectivedoseforchildrenininterventionalcardiology