Development of a Fully Automated Microfluidic Electrochemical Sensor on the ESSENCE Platform for Rapid Detection of Single-Stranded DNA

This study presents a fully automated microfluidic electrochemical sensor for the detection of single-stranded DNA (ssDNA) on the ESSENCE platform. The sensor utilizes functionalized single-walled carbon nanotubes (SWCNTs) with short ssDNA strands immobilized through EDC-NHS coupling, placed between...

Full description

Saved in:
Bibliographic Details
Main Authors: Niranjan Haridas Menon, Maryom Rahman, Sagnik Basuray
Format: Article
Language:English
Published: MDPI AG 2024-05-01
Series:Proceedings
Subjects:
Online Access:https://www.mdpi.com/2504-3900/104/1/17
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850259759617277952
author Niranjan Haridas Menon
Maryom Rahman
Sagnik Basuray
author_facet Niranjan Haridas Menon
Maryom Rahman
Sagnik Basuray
author_sort Niranjan Haridas Menon
collection DOAJ
description This study presents a fully automated microfluidic electrochemical sensor for the detection of single-stranded DNA (ssDNA) on the ESSENCE platform. The sensor utilizes functionalized single-walled carbon nanotubes (SWCNTs) with short ssDNA strands immobilized through EDC-NHS coupling, placed between non-planar interdigitated electrodes. The detection process involves sequential flow of a background electrolyte and redox probe through the microfluidic channel before introducing the target DNA solution. The same solution is then circulated to enhance selectivity by removing non-specifically bound targets. Electrochemical impedance signals are acquired after the initial and final flow steps, utilizing changes in impedance spectra to quantify target DNA concentration. To streamline complex flow steps and eliminate manual interventions, the system integrates a fully automated fluid control system with syringe pumps, valves, and pressure sensors. Electrochemical impedance spectroscopy (EIS) data is acquired using the Analog Discovery 2 USB oscilloscope, and LabVIEW automation ensures a seamless transition from sample introduction to data acquisition. The transducer material’s flow-through design enables efficient differentiation between different degrees of base pair mismatches, extending applicability to single nucleotide polymorphisms. The system exhibits high sensitivity, detecting single-stranded DNA at concentrations as low as 1 fM within a rapid 15-min detection time. Its compact design and automated data acquisition make it a promising candidate for point-of-care biomolecule sensing, including antigens and toxins. Future applications involve functionalizing SWCNTs with relevant antibodies to enhance the platform’s capabilities for detecting a diverse range of target molecules in clinical settings.
format Article
id doaj-art-3c6bb29feea5490494edcde0c3fa0cd7
institution OA Journals
issn 2504-3900
language English
publishDate 2024-05-01
publisher MDPI AG
record_format Article
series Proceedings
spelling doaj-art-3c6bb29feea5490494edcde0c3fa0cd72025-08-20T01:55:48ZengMDPI AGProceedings2504-39002024-05-0110411710.3390/proceedings2024104017Development of a Fully Automated Microfluidic Electrochemical Sensor on the ESSENCE Platform for Rapid Detection of Single-Stranded DNANiranjan Haridas Menon0Maryom Rahman1Sagnik Basuray2Chemical and Materials Engineering Department, New Jersey Institue of Technology, Newark, NJ 07029, USAChemical and Materials Engineering Department, New Jersey Institue of Technology, Newark, NJ 07029, USAChemical and Materials Engineering Department, New Jersey Institue of Technology, Newark, NJ 07029, USAThis study presents a fully automated microfluidic electrochemical sensor for the detection of single-stranded DNA (ssDNA) on the ESSENCE platform. The sensor utilizes functionalized single-walled carbon nanotubes (SWCNTs) with short ssDNA strands immobilized through EDC-NHS coupling, placed between non-planar interdigitated electrodes. The detection process involves sequential flow of a background electrolyte and redox probe through the microfluidic channel before introducing the target DNA solution. The same solution is then circulated to enhance selectivity by removing non-specifically bound targets. Electrochemical impedance signals are acquired after the initial and final flow steps, utilizing changes in impedance spectra to quantify target DNA concentration. To streamline complex flow steps and eliminate manual interventions, the system integrates a fully automated fluid control system with syringe pumps, valves, and pressure sensors. Electrochemical impedance spectroscopy (EIS) data is acquired using the Analog Discovery 2 USB oscilloscope, and LabVIEW automation ensures a seamless transition from sample introduction to data acquisition. The transducer material’s flow-through design enables efficient differentiation between different degrees of base pair mismatches, extending applicability to single nucleotide polymorphisms. The system exhibits high sensitivity, detecting single-stranded DNA at concentrations as low as 1 fM within a rapid 15-min detection time. Its compact design and automated data acquisition make it a promising candidate for point-of-care biomolecule sensing, including antigens and toxins. Future applications involve functionalizing SWCNTs with relevant antibodies to enhance the platform’s capabilities for detecting a diverse range of target molecules in clinical settings.https://www.mdpi.com/2504-3900/104/1/17biosensorDNAmicrofluidicsautomationCNT
spellingShingle Niranjan Haridas Menon
Maryom Rahman
Sagnik Basuray
Development of a Fully Automated Microfluidic Electrochemical Sensor on the ESSENCE Platform for Rapid Detection of Single-Stranded DNA
Proceedings
biosensor
DNA
microfluidics
automation
CNT
title Development of a Fully Automated Microfluidic Electrochemical Sensor on the ESSENCE Platform for Rapid Detection of Single-Stranded DNA
title_full Development of a Fully Automated Microfluidic Electrochemical Sensor on the ESSENCE Platform for Rapid Detection of Single-Stranded DNA
title_fullStr Development of a Fully Automated Microfluidic Electrochemical Sensor on the ESSENCE Platform for Rapid Detection of Single-Stranded DNA
title_full_unstemmed Development of a Fully Automated Microfluidic Electrochemical Sensor on the ESSENCE Platform for Rapid Detection of Single-Stranded DNA
title_short Development of a Fully Automated Microfluidic Electrochemical Sensor on the ESSENCE Platform for Rapid Detection of Single-Stranded DNA
title_sort development of a fully automated microfluidic electrochemical sensor on the essence platform for rapid detection of single stranded dna
topic biosensor
DNA
microfluidics
automation
CNT
url https://www.mdpi.com/2504-3900/104/1/17
work_keys_str_mv AT niranjanharidasmenon developmentofafullyautomatedmicrofluidicelectrochemicalsensorontheessenceplatformforrapiddetectionofsinglestrandeddna
AT maryomrahman developmentofafullyautomatedmicrofluidicelectrochemicalsensorontheessenceplatformforrapiddetectionofsinglestrandeddna
AT sagnikbasuray developmentofafullyautomatedmicrofluidicelectrochemicalsensorontheessenceplatformforrapiddetectionofsinglestrandeddna