Validation and study of different parameters in the simulation of diagnostic X-ray spectra using the MCNPX code

In radiology, knowing the X-ray spectrum characteristics makes it possible to estimate the absorbed dose in the patient and to improve image quality. In this study, an X-ray generator was proposed using the MCNPX code and to validate it, the simulated spectrum was compared to the data provided from...

Full description

Saved in:
Bibliographic Details
Main Authors: K.C.W. Consatti, W. S. Santos, J. V. B. Valença, M. T. Yoshizumi
Format: Article
Language:English
Published: Brazilian Radiation Protection Society (Sociedade Brasileira de Proteção Radiológica, SBPR) 2023-03-01
Series:Brazilian Journal of Radiation Sciences
Subjects:
Online Access:https://bjrs.org.br/revista/index.php/REVISTA/article/view/2119
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849714978829893632
author K.C.W. Consatti
W. S. Santos
J. V. B. Valença
M. T. Yoshizumi
author_facet K.C.W. Consatti
W. S. Santos
J. V. B. Valença
M. T. Yoshizumi
author_sort K.C.W. Consatti
collection DOAJ
description In radiology, knowing the X-ray spectrum characteristics makes it possible to estimate the absorbed dose in the patient and to improve image quality. In this study, an X-ray generator was proposed using the MCNPX code and to validate it, the simulated spectrum was compared to the data provided from AAPM Task Group 195, which resulted in a percentage difference of 8.7%. Furthermore, several X-ray spectra were generated and compared to the spectra obtained from commercially available softwares as xpecgen and SpekCalc. The percentage differences were of the order of 13% in comparison with SpekCalc and 8% with xpecgen. The major differences obtained between those spectra were concentrated in the region of characteristic peaks, independently if variations in electron beam energy, target angle or filtration thickness were performed.
format Article
id doaj-art-3bf34ed5a0c84d458d932df3505bc5d0
institution DOAJ
issn 2319-0612
language English
publishDate 2023-03-01
publisher Brazilian Radiation Protection Society (Sociedade Brasileira de Proteção Radiológica, SBPR)
record_format Article
series Brazilian Journal of Radiation Sciences
spelling doaj-art-3bf34ed5a0c84d458d932df3505bc5d02025-08-20T03:13:32ZengBrazilian Radiation Protection Society (Sociedade Brasileira de Proteção Radiológica, SBPR)Brazilian Journal of Radiation Sciences2319-06122023-03-01110111810.15392/2319-0612.2023.21191737Validation and study of different parameters in the simulation of diagnostic X-ray spectra using the MCNPX codeK.C.W. Consatti0W. S. Santos1J. V. B. Valença2M. T. Yoshizumi3Universidade Federal de Ciências da Saúde de Porto Alegre (UFCSPA)Universidade Federal de Uberlândia (UFU)Universidade Federal de Ciências da Saúde de Porto Alegre (UFCSPA)Universidade Federal de Ciências da Saúde de Porto Alegre (UFCSPA)In radiology, knowing the X-ray spectrum characteristics makes it possible to estimate the absorbed dose in the patient and to improve image quality. In this study, an X-ray generator was proposed using the MCNPX code and to validate it, the simulated spectrum was compared to the data provided from AAPM Task Group 195, which resulted in a percentage difference of 8.7%. Furthermore, several X-ray spectra were generated and compared to the spectra obtained from commercially available softwares as xpecgen and SpekCalc. The percentage differences were of the order of 13% in comparison with SpekCalc and 8% with xpecgen. The major differences obtained between those spectra were concentrated in the region of characteristic peaks, independently if variations in electron beam energy, target angle or filtration thickness were performed.https://bjrs.org.br/revista/index.php/REVISTA/article/view/2119x-ray spectrummonte carlo simulationmcnpx
spellingShingle K.C.W. Consatti
W. S. Santos
J. V. B. Valença
M. T. Yoshizumi
Validation and study of different parameters in the simulation of diagnostic X-ray spectra using the MCNPX code
Brazilian Journal of Radiation Sciences
x-ray spectrum
monte carlo simulation
mcnpx
title Validation and study of different parameters in the simulation of diagnostic X-ray spectra using the MCNPX code
title_full Validation and study of different parameters in the simulation of diagnostic X-ray spectra using the MCNPX code
title_fullStr Validation and study of different parameters in the simulation of diagnostic X-ray spectra using the MCNPX code
title_full_unstemmed Validation and study of different parameters in the simulation of diagnostic X-ray spectra using the MCNPX code
title_short Validation and study of different parameters in the simulation of diagnostic X-ray spectra using the MCNPX code
title_sort validation and study of different parameters in the simulation of diagnostic x ray spectra using the mcnpx code
topic x-ray spectrum
monte carlo simulation
mcnpx
url https://bjrs.org.br/revista/index.php/REVISTA/article/view/2119
work_keys_str_mv AT kcwconsatti validationandstudyofdifferentparametersinthesimulationofdiagnosticxrayspectrausingthemcnpxcode
AT wssantos validationandstudyofdifferentparametersinthesimulationofdiagnosticxrayspectrausingthemcnpxcode
AT jvbvalenca validationandstudyofdifferentparametersinthesimulationofdiagnosticxrayspectrausingthemcnpxcode
AT mtyoshizumi validationandstudyofdifferentparametersinthesimulationofdiagnosticxrayspectrausingthemcnpxcode