Radiation Safety in the Neonatal Intensive Care Unit: Too Little or Too Much Concern?

With rising numbers of extremely premature infants in the neonatal intensive care unit (NICU) who require multiple radiologic examinations for their complex medical conditions, concerns the risk of radiation exposure become a more prevalent issue. The biological effects from cumulative doses of both...

Full description

Saved in:
Bibliographic Details
Main Author: Cheng-Chung Yu
Format: Article
Language:English
Published: Elsevier 2010-12-01
Series:Pediatrics and Neonatology
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S1875957210600617
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849322685319872512
author Cheng-Chung Yu
author_facet Cheng-Chung Yu
author_sort Cheng-Chung Yu
collection DOAJ
description With rising numbers of extremely premature infants in the neonatal intensive care unit (NICU) who require multiple radiologic examinations for their complex medical conditions, concerns the risk of radiation exposure become a more prevalent issue. The biological effects from cumulative doses of both primary and secondary radiation can be particularly troubling for very premature babies due to their inherent sensitivity to both iatrogenic and environmental insults. Similarly, radiologic studies performed in the NICU pose potentially significant exposure risks to caretakers and to the families of patients often present in the NICU during these examinations. The purpose of this article is to critically review the available literature regarding current exposure rates in the NICU, address the validity of radiation exposure concerns, and suggest areas for improvement. With few exceptions, studies reveal that there were only low doses of radiation derived from any single radiographic examination in standard NICUs and that the radiation dosage used was in compliance with recommendations made by the Commission of European Communities (EC) and International Commission on Radiological Protection (ICRP). However, there were wide variations in the radiation dose per single examination (mean entrance skin doses ranged from 15 to 73.6 μGy) and in the frequency (mean ranged from 3.2 to 31 examinations per infant) of those examinations. Studies also reported low secondary exposure rates from scatter radiation to others present in the NICU during radiographic examinations. Key to limiting unnecessary radiation exposure in the NICU is the employment of proper radiation techniques and safety measures. Thus, adhering to recommendations made by the EC and ICRP can help to reduce the anxiety of patients' families and medical staff regarding their risks from the effects of ionizing radiation in the NICU.
format Article
id doaj-art-3bb698ba62e64c8c8fec8e50615bd4d0
institution Kabale University
issn 1875-9572
language English
publishDate 2010-12-01
publisher Elsevier
record_format Article
series Pediatrics and Neonatology
spelling doaj-art-3bb698ba62e64c8c8fec8e50615bd4d02025-08-20T03:49:17ZengElsevierPediatrics and Neonatology1875-95722010-12-0151631131910.1016/S1875-9572(10)60061-7Radiation Safety in the Neonatal Intensive Care Unit: Too Little or Too Much Concern?Cheng-Chung YuWith rising numbers of extremely premature infants in the neonatal intensive care unit (NICU) who require multiple radiologic examinations for their complex medical conditions, concerns the risk of radiation exposure become a more prevalent issue. The biological effects from cumulative doses of both primary and secondary radiation can be particularly troubling for very premature babies due to their inherent sensitivity to both iatrogenic and environmental insults. Similarly, radiologic studies performed in the NICU pose potentially significant exposure risks to caretakers and to the families of patients often present in the NICU during these examinations. The purpose of this article is to critically review the available literature regarding current exposure rates in the NICU, address the validity of radiation exposure concerns, and suggest areas for improvement. With few exceptions, studies reveal that there were only low doses of radiation derived from any single radiographic examination in standard NICUs and that the radiation dosage used was in compliance with recommendations made by the Commission of European Communities (EC) and International Commission on Radiological Protection (ICRP). However, there were wide variations in the radiation dose per single examination (mean entrance skin doses ranged from 15 to 73.6 μGy) and in the frequency (mean ranged from 3.2 to 31 examinations per infant) of those examinations. Studies also reported low secondary exposure rates from scatter radiation to others present in the NICU during radiographic examinations. Key to limiting unnecessary radiation exposure in the NICU is the employment of proper radiation techniques and safety measures. Thus, adhering to recommendations made by the EC and ICRP can help to reduce the anxiety of patients' families and medical staff regarding their risks from the effects of ionizing radiation in the NICU.http://www.sciencedirect.com/science/article/pii/S1875957210600617newborn intensive care unitradiation doseradiation exposureradiation safetyX-ray
spellingShingle Cheng-Chung Yu
Radiation Safety in the Neonatal Intensive Care Unit: Too Little or Too Much Concern?
Pediatrics and Neonatology
newborn intensive care unit
radiation dose
radiation exposure
radiation safety
X-ray
title Radiation Safety in the Neonatal Intensive Care Unit: Too Little or Too Much Concern?
title_full Radiation Safety in the Neonatal Intensive Care Unit: Too Little or Too Much Concern?
title_fullStr Radiation Safety in the Neonatal Intensive Care Unit: Too Little or Too Much Concern?
title_full_unstemmed Radiation Safety in the Neonatal Intensive Care Unit: Too Little or Too Much Concern?
title_short Radiation Safety in the Neonatal Intensive Care Unit: Too Little or Too Much Concern?
title_sort radiation safety in the neonatal intensive care unit too little or too much concern
topic newborn intensive care unit
radiation dose
radiation exposure
radiation safety
X-ray
url http://www.sciencedirect.com/science/article/pii/S1875957210600617
work_keys_str_mv AT chengchungyu radiationsafetyintheneonatalintensivecareunittoolittleortoomuchconcern