Effect of Web Opening Location on Fatigue Assessment of H Section Steel Beams
In the last decades, steel beams with web opening were used extensively as useful structural and architectural elements due to their many advantages. In this research, steel beams with web opening subjected to static loading were modelled using the multi-purpose finite element software ANSYS and the...
Saved in:
| Main Authors: | , , , |
|---|---|
| Format: | Article |
| Language: | Arabic |
| Published: |
Faculty of Engineering, Tanta University
2022-01-01
|
| Series: | Journal of Engineering Research - Egypt |
| Subjects: | |
| Online Access: | https://erjeng.journals.ekb.eg/article_212332_c8c1ac354c01ceb216cdbaa45c892961.pdf |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1850159043510796288 |
|---|---|
| author | Ahmed Elboghdady Mohamed Dabaon Nashwa Yossef Mahmoud El-Boghdadi |
| author_facet | Ahmed Elboghdady Mohamed Dabaon Nashwa Yossef Mahmoud El-Boghdadi |
| author_sort | Ahmed Elboghdady |
| collection | DOAJ |
| description | In the last decades, steel beams with web opening were used extensively as useful structural and architectural elements due to their many advantages. In this research, steel beams with web opening subjected to static loading were modelled using the multi-purpose finite element software ANSYS and the finite element results were compared with previous research. Then, steel beams with a single web opening subjected to fatigue loading were investigated numerically. The effect of changing the location of web opening on the fatigue assessment of H section steel beams with web opening was studied taking normal stress into account. It was clear that, normal stress fatigue life of the steel beams was affected significantly by changing web opening location along the beam span when compared to a beam with solid web while the beam span, opening size and steel section were kept constant. The most convenient location of web opening along the beam span was found to be at mid span. |
| format | Article |
| id | doaj-art-3a391e293b5a447384d2c0e744121741 |
| institution | OA Journals |
| issn | 2356-9441 2735-4873 |
| language | Arabic |
| publishDate | 2022-01-01 |
| publisher | Faculty of Engineering, Tanta University |
| record_format | Article |
| series | Journal of Engineering Research - Egypt |
| spelling | doaj-art-3a391e293b5a447384d2c0e7441217412025-08-20T02:23:41ZaraFaculty of Engineering, Tanta UniversityJournal of Engineering Research - Egypt2356-94412735-48732022-01-0154919610.21608/erjeng.2022.111563.1045212332Effect of Web Opening Location on Fatigue Assessment of H Section Steel BeamsAhmed Elboghdady0Mohamed Dabaon1Nashwa Yossef2Mahmoud El-Boghdadi3Civil Engineering Dept., Faculty of Engineering, Horus University, New Damietta, EgyptProfessor of Metallic Structures, Vice President of Tanta University, Tanta, Egypt, Dean of faculty of engineering Horus University in EgyptProfessor of Metallic Structures, Structural Engineering Dept., Faculty of Engineering, Tanta University, Tanta, EgyptAssoc. Prof. Structural Engineering Dept., Tanta University, Tanta, Egypt.In the last decades, steel beams with web opening were used extensively as useful structural and architectural elements due to their many advantages. In this research, steel beams with web opening subjected to static loading were modelled using the multi-purpose finite element software ANSYS and the finite element results were compared with previous research. Then, steel beams with a single web opening subjected to fatigue loading were investigated numerically. The effect of changing the location of web opening on the fatigue assessment of H section steel beams with web opening was studied taking normal stress into account. It was clear that, normal stress fatigue life of the steel beams was affected significantly by changing web opening location along the beam span when compared to a beam with solid web while the beam span, opening size and steel section were kept constant. The most convenient location of web opening along the beam span was found to be at mid span.https://erjeng.journals.ekb.eg/article_212332_c8c1ac354c01ceb216cdbaa45c892961.pdffinite element studyweb openingopening locationfatigue loading |
| spellingShingle | Ahmed Elboghdady Mohamed Dabaon Nashwa Yossef Mahmoud El-Boghdadi Effect of Web Opening Location on Fatigue Assessment of H Section Steel Beams Journal of Engineering Research - Egypt finite element study web opening opening location fatigue loading |
| title | Effect of Web Opening Location on Fatigue Assessment of H Section Steel Beams |
| title_full | Effect of Web Opening Location on Fatigue Assessment of H Section Steel Beams |
| title_fullStr | Effect of Web Opening Location on Fatigue Assessment of H Section Steel Beams |
| title_full_unstemmed | Effect of Web Opening Location on Fatigue Assessment of H Section Steel Beams |
| title_short | Effect of Web Opening Location on Fatigue Assessment of H Section Steel Beams |
| title_sort | effect of web opening location on fatigue assessment of h section steel beams |
| topic | finite element study web opening opening location fatigue loading |
| url | https://erjeng.journals.ekb.eg/article_212332_c8c1ac354c01ceb216cdbaa45c892961.pdf |
| work_keys_str_mv | AT ahmedelboghdady effectofwebopeninglocationonfatigueassessmentofhsectionsteelbeams AT mohameddabaon effectofwebopeninglocationonfatigueassessmentofhsectionsteelbeams AT nashwayossef effectofwebopeninglocationonfatigueassessmentofhsectionsteelbeams AT mahmoudelboghdadi effectofwebopeninglocationonfatigueassessmentofhsectionsteelbeams |