Ultrasound-Guided Percutaneous Microwave Coagulation Studies on VX2 Rabbit Models for Breast Cancer Treatment and Ultrasound Imaging Assessment

Qi Gao,1,* Hu Huang,2,* Jin-Jun Shi,1 Ling Wang,1 Wei-Min Li3 1Department of Ultrasonography, Zhongda Hospital, Medical School, Southeast University, Nanjing, Jiangsu, People’s Republic of China; 2Department of Thyroid and Breast Surgery, Affiliated Hospital of Jiangnan University, W...

Full description

Saved in:
Bibliographic Details
Main Authors: Gao Q, Huang H, Shi JJ, Wang L, Li WM
Format: Article
Language:English
Published: Dove Medical Press 2025-02-01
Series:Breast Cancer: Targets and Therapy
Subjects:
Online Access:https://www.dovepress.com/ultrasound-guided-percutaneous-microwave-coagulation-studies-on-vx2-ra-peer-reviewed-fulltext-article-BCTT
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850238656423395328
author Gao Q
Huang H
Shi JJ
Wang L
Li WM
author_facet Gao Q
Huang H
Shi JJ
Wang L
Li WM
author_sort Gao Q
collection DOAJ
description Qi Gao,1,&ast; Hu Huang,2,&ast; Jin-Jun Shi,1 Ling Wang,1 Wei-Min Li3 1Department of Ultrasonography, Zhongda Hospital, Medical School, Southeast University, Nanjing, Jiangsu, People’s Republic of China; 2Department of Thyroid and Breast Surgery, Affiliated Hospital of Jiangnan University, Wuxi, Jiangsu, People’s Republic of China; 3Department of Ultrasonography, Affiliated Hospital of Jiangnan University, Wuxi, Jiangsu, People’s Republic of China&ast;These authors contributed equally to this workCorrespondence: Wei-Min Li, Department of Ultrasonography, Affiliated Hospital of Jiangnan University, Wuxi, Jiangsu, 214000, People’s Republic of China, Tel +8613912362309, Email 1005342597@qq.com Ling Wang, Department of Ultrasonography, Zhongda Hospital, Medical School, Southeast University, Nanjing, Jiangsu, 210009, People’s Republic of China, Tel +8613852292915, Email wl031995@163.comBackground: The study aimed to explore the tissue morphology and hemodynamics of rabbit VX2 breast carcinoma by high-frequency ultrasound (US) and the effectiveness and safety of US-guided percutaneous microwave coagulation (PMC) therapy on rabbit VX2 breast tumors.Methods: Twenty VX2 tumor-bearing rabbits were assessed using color Doppler ultrasound for tumor growth characteristics including echo, size, blood supply and hemodynamic parameters once a week for six weeks. Subsequently, US-guided PMC was performed in randomly assigned ten VX2 tumor-bearing rabbits (the other ten as controls). US images after ablation were obtained and analyzed. Three rabbits with double VX2 tumors were used as pathological observation at weeks 0, 1, and 4 of ablation. The therapeutic efficacy was evaluated by tumor growth, physical examinations, survival time, survival rate and metastasis of tumors and histopathology.Results: Ultrasound monitoring indicated that the tumor growth rate was 463.09% at the 2nd to 3rd weeks, and PMC was performed during this period under real-time US guidance. After microwave ablation, some tumors were greatly reduced or undetectable at week 8. Moreover, no flow signals were detected by US. The survival rates at 2 and 3 months in the treatment group and control group were 100%, 70% and 10%, 0%, respectively, while the metastatic rates were 10%, 30% and 90%, 100%, respectively (P< 0.05).Conclusion: The proliferation and metastasis of rabbit VX2 breast carcinoma were monitored by US imaging, and US-guided percutaneous microwave ablation was proven to be a safe, effective and minimally invasive therapeutic option for treating breast cancer in rabbits, showing potential clinical applicability.Keywords: percutaneous microwave, VX2 rabbit models, breast cancer, ultrasound
format Article
id doaj-art-3a000427a7bf4e2e830c2e4af10d3300
institution OA Journals
issn 1179-1314
language English
publishDate 2025-02-01
publisher Dove Medical Press
record_format Article
series Breast Cancer: Targets and Therapy
spelling doaj-art-3a000427a7bf4e2e830c2e4af10d33002025-08-20T02:01:24ZengDove Medical PressBreast Cancer: Targets and Therapy1179-13142025-02-01Volume 17241252100529Ultrasound-Guided Percutaneous Microwave Coagulation Studies on VX2 Rabbit Models for Breast Cancer Treatment and Ultrasound Imaging AssessmentGao QHuang HShi JJWang LLi WMQi Gao,1,&ast; Hu Huang,2,&ast; Jin-Jun Shi,1 Ling Wang,1 Wei-Min Li3 1Department of Ultrasonography, Zhongda Hospital, Medical School, Southeast University, Nanjing, Jiangsu, People’s Republic of China; 2Department of Thyroid and Breast Surgery, Affiliated Hospital of Jiangnan University, Wuxi, Jiangsu, People’s Republic of China; 3Department of Ultrasonography, Affiliated Hospital of Jiangnan University, Wuxi, Jiangsu, People’s Republic of China&ast;These authors contributed equally to this workCorrespondence: Wei-Min Li, Department of Ultrasonography, Affiliated Hospital of Jiangnan University, Wuxi, Jiangsu, 214000, People’s Republic of China, Tel +8613912362309, Email 1005342597@qq.com Ling Wang, Department of Ultrasonography, Zhongda Hospital, Medical School, Southeast University, Nanjing, Jiangsu, 210009, People’s Republic of China, Tel +8613852292915, Email wl031995@163.comBackground: The study aimed to explore the tissue morphology and hemodynamics of rabbit VX2 breast carcinoma by high-frequency ultrasound (US) and the effectiveness and safety of US-guided percutaneous microwave coagulation (PMC) therapy on rabbit VX2 breast tumors.Methods: Twenty VX2 tumor-bearing rabbits were assessed using color Doppler ultrasound for tumor growth characteristics including echo, size, blood supply and hemodynamic parameters once a week for six weeks. Subsequently, US-guided PMC was performed in randomly assigned ten VX2 tumor-bearing rabbits (the other ten as controls). US images after ablation were obtained and analyzed. Three rabbits with double VX2 tumors were used as pathological observation at weeks 0, 1, and 4 of ablation. The therapeutic efficacy was evaluated by tumor growth, physical examinations, survival time, survival rate and metastasis of tumors and histopathology.Results: Ultrasound monitoring indicated that the tumor growth rate was 463.09% at the 2nd to 3rd weeks, and PMC was performed during this period under real-time US guidance. After microwave ablation, some tumors were greatly reduced or undetectable at week 8. Moreover, no flow signals were detected by US. The survival rates at 2 and 3 months in the treatment group and control group were 100%, 70% and 10%, 0%, respectively, while the metastatic rates were 10%, 30% and 90%, 100%, respectively (P< 0.05).Conclusion: The proliferation and metastasis of rabbit VX2 breast carcinoma were monitored by US imaging, and US-guided percutaneous microwave ablation was proven to be a safe, effective and minimally invasive therapeutic option for treating breast cancer in rabbits, showing potential clinical applicability.Keywords: percutaneous microwave, VX2 rabbit models, breast cancer, ultrasoundhttps://www.dovepress.com/ultrasound-guided-percutaneous-microwave-coagulation-studies-on-vx2-ra-peer-reviewed-fulltext-article-BCTTpercutaneous microwavevx2 rabbit modelsbreast cancerultrasound
spellingShingle Gao Q
Huang H
Shi JJ
Wang L
Li WM
Ultrasound-Guided Percutaneous Microwave Coagulation Studies on VX2 Rabbit Models for Breast Cancer Treatment and Ultrasound Imaging Assessment
Breast Cancer: Targets and Therapy
percutaneous microwave
vx2 rabbit models
breast cancer
ultrasound
title Ultrasound-Guided Percutaneous Microwave Coagulation Studies on VX2 Rabbit Models for Breast Cancer Treatment and Ultrasound Imaging Assessment
title_full Ultrasound-Guided Percutaneous Microwave Coagulation Studies on VX2 Rabbit Models for Breast Cancer Treatment and Ultrasound Imaging Assessment
title_fullStr Ultrasound-Guided Percutaneous Microwave Coagulation Studies on VX2 Rabbit Models for Breast Cancer Treatment and Ultrasound Imaging Assessment
title_full_unstemmed Ultrasound-Guided Percutaneous Microwave Coagulation Studies on VX2 Rabbit Models for Breast Cancer Treatment and Ultrasound Imaging Assessment
title_short Ultrasound-Guided Percutaneous Microwave Coagulation Studies on VX2 Rabbit Models for Breast Cancer Treatment and Ultrasound Imaging Assessment
title_sort ultrasound guided percutaneous microwave coagulation studies on vx2 rabbit models for breast cancer treatment and ultrasound imaging assessment
topic percutaneous microwave
vx2 rabbit models
breast cancer
ultrasound
url https://www.dovepress.com/ultrasound-guided-percutaneous-microwave-coagulation-studies-on-vx2-ra-peer-reviewed-fulltext-article-BCTT
work_keys_str_mv AT gaoq ultrasoundguidedpercutaneousmicrowavecoagulationstudiesonvx2rabbitmodelsforbreastcancertreatmentandultrasoundimagingassessment
AT huangh ultrasoundguidedpercutaneousmicrowavecoagulationstudiesonvx2rabbitmodelsforbreastcancertreatmentandultrasoundimagingassessment
AT shijj ultrasoundguidedpercutaneousmicrowavecoagulationstudiesonvx2rabbitmodelsforbreastcancertreatmentandultrasoundimagingassessment
AT wangl ultrasoundguidedpercutaneousmicrowavecoagulationstudiesonvx2rabbitmodelsforbreastcancertreatmentandultrasoundimagingassessment
AT liwm ultrasoundguidedpercutaneousmicrowavecoagulationstudiesonvx2rabbitmodelsforbreastcancertreatmentandultrasoundimagingassessment