Research and Application of Comprehensive Algorithm of Relay Protection Status Assessment Based on Gray Correlation Analysis and TOPSIS Method

At present, the state evaluation for relay devices is too simple, subjective and inconvenient. To make the state evaluation of the relay devices more accurately reflect the state of targeted devices and provide more comprehensive information, a comprehensive evaluation system is established for rela...

Full description

Saved in:
Bibliographic Details
Main Authors: Guosheng YANG, Feiyang DAI, Wenhuan WANG, Peng GUO, Yanfei LI
Format: Article
Language:zho
Published: State Grid Energy Research Institute 2019-02-01
Series:Zhongguo dianli
Subjects:
Online Access:https://www.electricpower.com.cn/CN/10.11930/j.issn.1004-9649.201801178
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850051142727237632
author Guosheng YANG
Feiyang DAI
Wenhuan WANG
Peng GUO
Yanfei LI
author_facet Guosheng YANG
Feiyang DAI
Wenhuan WANG
Peng GUO
Yanfei LI
author_sort Guosheng YANG
collection DOAJ
description At present, the state evaluation for relay devices is too simple, subjective and inconvenient. To make the state evaluation of the relay devices more accurately reflect the state of targeted devices and provide more comprehensive information, a comprehensive evaluation system is established for relay protection and a whole-cycle multi-dimension on-line assessment method is proposed based on combined evaluation methods. Considering the operation conditions of protective devices over the recent years and on the basis of the randomness, fuzziness, importance and feasibility of current assessment method, the fuzzy mathematics theory, TOPSIS method and variable weight analysis method are introduced to optimize all aspects of the protection evaluation work with combination of the cloud method to ensure the objectiveness of the evaluation result. The case study has proved the effectiveness of the proposed method.
format Article
id doaj-art-38eee366cef94a959f160d77cd56cf20
institution DOAJ
issn 1004-9649
language zho
publishDate 2019-02-01
publisher State Grid Energy Research Institute
record_format Article
series Zhongguo dianli
spelling doaj-art-38eee366cef94a959f160d77cd56cf202025-08-20T02:53:14ZzhoState Grid Energy Research InstituteZhongguo dianli1004-96492019-02-015229410310.11930/j.issn.1004-9649.201801178zgdl-52-1-yangguoshengResearch and Application of Comprehensive Algorithm of Relay Protection Status Assessment Based on Gray Correlation Analysis and TOPSIS MethodGuosheng YANG0Feiyang DAI1Wenhuan WANG2Peng GUO3Yanfei LI4China Electric Power Research Institute, Beijing 100192, ChinaChina Electric Power Research Institute, Beijing 100192, ChinaChina Electric Power Research Institute, Beijing 100192, ChinaChina Electric Power Research Institute, Beijing 100192, ChinaChina Electric Power Research Institute, Beijing 100192, ChinaAt present, the state evaluation for relay devices is too simple, subjective and inconvenient. To make the state evaluation of the relay devices more accurately reflect the state of targeted devices and provide more comprehensive information, a comprehensive evaluation system is established for relay protection and a whole-cycle multi-dimension on-line assessment method is proposed based on combined evaluation methods. Considering the operation conditions of protective devices over the recent years and on the basis of the randomness, fuzziness, importance and feasibility of current assessment method, the fuzzy mathematics theory, TOPSIS method and variable weight analysis method are introduced to optimize all aspects of the protection evaluation work with combination of the cloud method to ensure the objectiveness of the evaluation result. The case study has proved the effectiveness of the proposed method.https://www.electricpower.com.cn/CN/10.11930/j.issn.1004-9649.201801178protective relaystate evaluationcloud modelgrey correlationtopsis methodvariable weight
spellingShingle Guosheng YANG
Feiyang DAI
Wenhuan WANG
Peng GUO
Yanfei LI
Research and Application of Comprehensive Algorithm of Relay Protection Status Assessment Based on Gray Correlation Analysis and TOPSIS Method
Zhongguo dianli
protective relay
state evaluation
cloud model
grey correlation
topsis method
variable weight
title Research and Application of Comprehensive Algorithm of Relay Protection Status Assessment Based on Gray Correlation Analysis and TOPSIS Method
title_full Research and Application of Comprehensive Algorithm of Relay Protection Status Assessment Based on Gray Correlation Analysis and TOPSIS Method
title_fullStr Research and Application of Comprehensive Algorithm of Relay Protection Status Assessment Based on Gray Correlation Analysis and TOPSIS Method
title_full_unstemmed Research and Application of Comprehensive Algorithm of Relay Protection Status Assessment Based on Gray Correlation Analysis and TOPSIS Method
title_short Research and Application of Comprehensive Algorithm of Relay Protection Status Assessment Based on Gray Correlation Analysis and TOPSIS Method
title_sort research and application of comprehensive algorithm of relay protection status assessment based on gray correlation analysis and topsis method
topic protective relay
state evaluation
cloud model
grey correlation
topsis method
variable weight
url https://www.electricpower.com.cn/CN/10.11930/j.issn.1004-9649.201801178
work_keys_str_mv AT guoshengyang researchandapplicationofcomprehensivealgorithmofrelayprotectionstatusassessmentbasedongraycorrelationanalysisandtopsismethod
AT feiyangdai researchandapplicationofcomprehensivealgorithmofrelayprotectionstatusassessmentbasedongraycorrelationanalysisandtopsismethod
AT wenhuanwang researchandapplicationofcomprehensivealgorithmofrelayprotectionstatusassessmentbasedongraycorrelationanalysisandtopsismethod
AT pengguo researchandapplicationofcomprehensivealgorithmofrelayprotectionstatusassessmentbasedongraycorrelationanalysisandtopsismethod
AT yanfeili researchandapplicationofcomprehensivealgorithmofrelayprotectionstatusassessmentbasedongraycorrelationanalysisandtopsismethod