CARDIOVERSION WITH BI- AND MONOPHASE DEFIBRILLATORS IN PATIENTS WITH PAROXYSMAL ATRIAL FIBRILLATION
The paper focuses on the effectiveness and safety of bi- and monophase defibrillators in patients with paroxysmal atrial fibrillation. In bi-phase defibrillator cardioversion, sinus rhythm was restored more often, and total defibrillation energy was substantially lower than in monophase defibrillato...
Saved in:
| Main Authors: | , , , , |
|---|---|
| Format: | Article |
| Language: | Russian |
| Published: |
«FIRMA «SILICEA» LLC
2010-02-01
|
| Series: | Российский кардиологический журнал |
| Subjects: | |
| Online Access: | https://russjcardiol.elpub.ru/jour/article/view/1418 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1850026942409998336 |
|---|---|
| author | V. A. Lusov I. A. Kokorin V. A. Kokorin N. A. Volov A. P. Goncharov |
| author_facet | V. A. Lusov I. A. Kokorin V. A. Kokorin N. A. Volov A. P. Goncharov |
| author_sort | V. A. Lusov |
| collection | DOAJ |
| description | The paper focuses on the effectiveness and safety of bi- and monophase defibrillators in patients with paroxysmal atrial fibrillation. In bi-phase defibrillator cardioversion, sinus rhythm was restored more often, and total defibrillation energy was substantially lower than in monophase defibrillator cardioversion. No significant differences in myocardial necrosis markers were observed. |
| format | Article |
| id | doaj-art-386fa847dadf4f4e82f9c31d7d2cfb9c |
| institution | DOAJ |
| issn | 1560-4071 2618-7620 |
| language | Russian |
| publishDate | 2010-02-01 |
| publisher | «FIRMA «SILICEA» LLC |
| record_format | Article |
| series | Российский кардиологический журнал |
| spelling | doaj-art-386fa847dadf4f4e82f9c31d7d2cfb9c2025-08-20T03:00:22Zrus«FIRMA «SILICEA» LLCРоссийский кардиологический журнал1560-40712618-76202010-02-010142461206CARDIOVERSION WITH BI- AND MONOPHASE DEFIBRILLATORS IN PATIENTS WITH PAROXYSMAL ATRIAL FIBRILLATIONV. A. Lusov0I. A. Kokorin1V. A. Kokorin2N. A. Volov3A. P. Goncharov4ГОУ ВПО РГМУ РЗ кафедра госпитальной терапии №1, МоскваГОУ ВПО РГМУ РЗ кафедра госпитальной терапии №1, МоскваГОУ ВПО РГМУ РЗ кафедра госпитальной терапии №1, МоскваГОУ ВПО РГМУ РЗ кафедра госпитальной терапии №1, МоскваГОУ ВПО РГМУ РЗ кафедра госпитальной терапии №1, МоскваThe paper focuses on the effectiveness and safety of bi- and monophase defibrillators in patients with paroxysmal atrial fibrillation. In bi-phase defibrillator cardioversion, sinus rhythm was restored more often, and total defibrillation energy was substantially lower than in monophase defibrillator cardioversion. No significant differences in myocardial necrosis markers were observed.https://russjcardiol.elpub.ru/jour/article/view/1418paroxysmal atrial fibrillationelectrical cardioversionbi- and monophase defibrillatorseffectivenesssafety |
| spellingShingle | V. A. Lusov I. A. Kokorin V. A. Kokorin N. A. Volov A. P. Goncharov CARDIOVERSION WITH BI- AND MONOPHASE DEFIBRILLATORS IN PATIENTS WITH PAROXYSMAL ATRIAL FIBRILLATION Российский кардиологический журнал paroxysmal atrial fibrillation electrical cardioversion bi- and monophase defibrillators effectiveness safety |
| title | CARDIOVERSION WITH BI- AND MONOPHASE DEFIBRILLATORS IN PATIENTS WITH PAROXYSMAL ATRIAL FIBRILLATION |
| title_full | CARDIOVERSION WITH BI- AND MONOPHASE DEFIBRILLATORS IN PATIENTS WITH PAROXYSMAL ATRIAL FIBRILLATION |
| title_fullStr | CARDIOVERSION WITH BI- AND MONOPHASE DEFIBRILLATORS IN PATIENTS WITH PAROXYSMAL ATRIAL FIBRILLATION |
| title_full_unstemmed | CARDIOVERSION WITH BI- AND MONOPHASE DEFIBRILLATORS IN PATIENTS WITH PAROXYSMAL ATRIAL FIBRILLATION |
| title_short | CARDIOVERSION WITH BI- AND MONOPHASE DEFIBRILLATORS IN PATIENTS WITH PAROXYSMAL ATRIAL FIBRILLATION |
| title_sort | cardioversion with bi and monophase defibrillators in patients with paroxysmal atrial fibrillation |
| topic | paroxysmal atrial fibrillation electrical cardioversion bi- and monophase defibrillators effectiveness safety |
| url | https://russjcardiol.elpub.ru/jour/article/view/1418 |
| work_keys_str_mv | AT valusov cardioversionwithbiandmonophasedefibrillatorsinpatientswithparoxysmalatrialfibrillation AT iakokorin cardioversionwithbiandmonophasedefibrillatorsinpatientswithparoxysmalatrialfibrillation AT vakokorin cardioversionwithbiandmonophasedefibrillatorsinpatientswithparoxysmalatrialfibrillation AT navolov cardioversionwithbiandmonophasedefibrillatorsinpatientswithparoxysmalatrialfibrillation AT apgoncharov cardioversionwithbiandmonophasedefibrillatorsinpatientswithparoxysmalatrialfibrillation |