Conventional scan body vs. scan bodies with auxiliary geometric devices: an in vitro study for edentulous full-arch implant impressions
AimThis study aimed to assess the effectiveness of an auxiliary geometric device (AGD) in enhancing the trueness of full-arch implant impressions. The primary metrics of interest were total surface deviation (TotRMS), centroid deviation (cRMS), and angular deviation. All these values are crucial for...
Saved in:
| Main Authors: | Francesco Gianfreda, Carlo Raffone, Mirko Martelli, Alberto Pitino, Vito Carlo Alberto Caponio, Patrizio Bollero |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Frontiers Media S.A.
2025-06-01
|
| Series: | Frontiers in Oral Health |
| Subjects: | |
| Online Access: | https://www.frontiersin.org/articles/10.3389/froh.2025.1574149/full |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Similar Items
-
Trueness of tooth modified scan bodies as a novel technique for edentulous full arch implant supported dental prosthesis: an in vivo prospective comparative study
by: Abdelrahman K. Eldabe, et al.
Published: (2025-01-01) -
Accuracy of Partial and Complete-Arch Conventional Versus Digital Impressions: An In-Vitro Study
by: Jeremy Chieng, et al.
Published: (2024-12-01) -
Accuracy of the digital implant impression with splinted and non-splinted intraoral scan bodies: A systematic review
by: Pratiksha Shankar Shetty, et al.
Published: (2025-01-01) -
Precision of Photogrammetry and Intraoral Scanning in Full-Arch Implant Rehabilitation: An In Vitro Comparative Study
by: João Carlos Faria, et al.
Published: (2025-01-01) -
Comparison of photogrammetric imaging, intraoral scanning and conventional impression accuracy of full-arch dental implant rehabilitation: an in vitro study
by: Kailibinuer Abuduwaili, et al.
Published: (2025-05-01)