Intensity of light impurities separation in vertically ascending air flow

In channels of pneumoseparators with vertical giving of an air flow process of separation of an easy component is casual because of a wrong form of caryopsis and irregularity in the distribution of an air stream on the cross section of the channel. Therefore the separated component can not be comple...

Full description

Saved in:
Bibliographic Details
Main Author: V. G. Khamuev
Format: Article
Language:Russian
Published: Federal Scientific Agroengineering Centre VIM 2016-10-01
Series:Сельскохозяйственные машины и технологии
Subjects:
Online Access:https://www.vimsmit.com/jour/article/view/147
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849253088102187008
author V. G. Khamuev
author_facet V. G. Khamuev
author_sort V. G. Khamuev
collection DOAJ
description In channels of pneumoseparators with vertical giving of an air flow process of separation of an easy component is casual because of a wrong form of caryopsis and irregularity in the distribution of an air stream on the cross section of the channel. Therefore the separated component can not be completely allocated for any final time of influence of an air flow. It is confirmed by the mathematical model which is adequately described by function of gamma distribution with arguments one of which is the important parameter of intensity of easy component separation. Just as the movement of a material point is determinet by its speed in each timepoint, and process of pneumoseparation is characterized on intensity of extraction of an easy component. The authors showed that this parameter makes the physical meaning opening possibility of an intensification of process of pneumoseparation that was not investigated adequately. Influence of grain charge on intensity of process of separation in vertically ascending air flow was studied. It is established that the increase in specific grain charge in the pneumoseparating channel with vertically ascending air flow is followed by increase of intensity of light impurities separation that can be explained by increase of speed of an air stream in intergrain space. When processing of barley at specific grain charge from 0.5 to 2 kg on sq. cm an hour intensity of impurity (oats) release increases depending on loading linearly. If intensity of process of separation at increase in loading from 0.5 to 2 kg on sq. cm per hour remained same as at charge of 0.5 kg of sq. cm per hour, settlement separation of oats at charge of 2 kg of sq. cm per hour would decrease from 51.97 percent (result of experience) to 9.83 percent. So, efficiency of separation with use of the pneumoseparating channel depend on change of grain charge.
format Article
id doaj-art-3732b97e4fa5425fb49fcf14562c0ee6
institution Kabale University
issn 2073-7599
language Russian
publishDate 2016-10-01
publisher Federal Scientific Agroengineering Centre VIM
record_format Article
series Сельскохозяйственные машины и технологии
spelling doaj-art-3732b97e4fa5425fb49fcf14562c0ee62025-08-20T03:56:27ZrusFederal Scientific Agroengineering Centre VIMСельскохозяйственные машины и технологии2073-75992016-10-01051216146Intensity of light impurities separation in vertically ascending air flowV. G. Khamuev0All-Russia Research Institute of Mechanization for AgricultureIn channels of pneumoseparators with vertical giving of an air flow process of separation of an easy component is casual because of a wrong form of caryopsis and irregularity in the distribution of an air stream on the cross section of the channel. Therefore the separated component can not be completely allocated for any final time of influence of an air flow. It is confirmed by the mathematical model which is adequately described by function of gamma distribution with arguments one of which is the important parameter of intensity of easy component separation. Just as the movement of a material point is determinet by its speed in each timepoint, and process of pneumoseparation is characterized on intensity of extraction of an easy component. The authors showed that this parameter makes the physical meaning opening possibility of an intensification of process of pneumoseparation that was not investigated adequately. Influence of grain charge on intensity of process of separation in vertically ascending air flow was studied. It is established that the increase in specific grain charge in the pneumoseparating channel with vertically ascending air flow is followed by increase of intensity of light impurities separation that can be explained by increase of speed of an air stream in intergrain space. When processing of barley at specific grain charge from 0.5 to 2 kg on sq. cm an hour intensity of impurity (oats) release increases depending on loading linearly. If intensity of process of separation at increase in loading from 0.5 to 2 kg on sq. cm per hour remained same as at charge of 0.5 kg of sq. cm per hour, settlement separation of oats at charge of 2 kg of sq. cm per hour would decrease from 51.97 percent (result of experience) to 9.83 percent. So, efficiency of separation with use of the pneumoseparating channel depend on change of grain charge.https://www.vimsmit.com/jour/article/view/147пневмосепарацияинтенсивность выноса легкой примесискорость воздушного потокаудельная зерновая нагрузкаполнота выделения примесиполная гамма-функцияpneumoseparationintensity of light impurities separationair flow speedspecific grain chargeimpurities separation efficiencycomplete gamma function
spellingShingle V. G. Khamuev
Intensity of light impurities separation in vertically ascending air flow
Сельскохозяйственные машины и технологии
пневмосепарация
интенсивность выноса легкой примеси
скорость воздушного потока
удельная зерновая нагрузка
полнота выделения примеси
полная гамма-функция
pneumoseparation
intensity of light impurities separation
air flow speed
specific grain charge
impurities separation efficiency
complete gamma function
title Intensity of light impurities separation in vertically ascending air flow
title_full Intensity of light impurities separation in vertically ascending air flow
title_fullStr Intensity of light impurities separation in vertically ascending air flow
title_full_unstemmed Intensity of light impurities separation in vertically ascending air flow
title_short Intensity of light impurities separation in vertically ascending air flow
title_sort intensity of light impurities separation in vertically ascending air flow
topic пневмосепарация
интенсивность выноса легкой примеси
скорость воздушного потока
удельная зерновая нагрузка
полнота выделения примеси
полная гамма-функция
pneumoseparation
intensity of light impurities separation
air flow speed
specific grain charge
impurities separation efficiency
complete gamma function
url https://www.vimsmit.com/jour/article/view/147
work_keys_str_mv AT vgkhamuev intensityoflightimpuritiesseparationinverticallyascendingairflow