High cut-off hemodialysis vs. high flux hemodialysis for free light chain removal: a case report and literature review

Objective To compare the high cut-off hemodialysis with high flux hemodialysis for free light chain removal,and to review literatures concerned. Methods A male aged59 was admitted due to " fatigue more than one year,aggravated two days". He felt fatigue one year ago and was diagnosed as mu...

Full description

Saved in:
Bibliographic Details
Main Authors: XU Feng-bo, SUN Yi, XUE Fei
Format: Article
Language:zho
Published: Editorial Department of Journal of Clinical Nephrology 2018-01-01
Series:Linchuang shenzangbing zazhi
Subjects:
Online Access:http://www.lcszb.com/thesisDetails?columnId=57915994&Fpath=home&index=0
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850274323318702080
author XU Feng-bo
SUN Yi
XUE Fei
author_facet XU Feng-bo
SUN Yi
XUE Fei
author_sort XU Feng-bo
collection DOAJ
description Objective To compare the high cut-off hemodialysis with high flux hemodialysis for free light chain removal,and to review literatures concerned. Methods A male aged59 was admitted due to " fatigue more than one year,aggravated two days". He felt fatigue one year ago and was diagnosed as multiple myeloma by bone marrow biopsy and increased free light chain. Then partial remission was achieved by thalidomide,adriamcin and dexamethasone. One week before,he felt weakness and chest pain,then a decrease in hemoglobin and acute renal failure were found,which was considered the recurrence of multiple myeloma. Cyclophosphamide,doxorubicin and dexamethasone chemotherapy was started. When the creatinine up to 611μmol/L,the hemodialysis treatment began. He received two times high flux hemodialysis( Fresenius FX60) first,then three times high cut-off hemodialysis( HCO2100). Time was four h and ultrafiltration was set at 0. 5 kg. Human albumin 10 g was replenished at high flux hemodialysis for 3. 5 h. The levels of serum FLCλ were detected by particle enhanced turbidimetric immunoassay,and those of serum albumin by automatic biochemical immunoassay before and after treatment.Results After two times high flux hemodialysis,serum levels of FLCλ were decreasedfrom 45. 9 to 36. 4 mg/L,and those of albumin changed from 31. 9 to 32. 7 mg/L respectively.After three times high cut-off hemodialysis,serum levels of FLC λ decreased from 42. 3 to 32. 1 mg/L,and those of albumin were decreased from 33 to 28 mg/L( 10 g albumin was added in each high cut-off hemodialysis). Conclusions We didn’t find the superiority of high cut-off hemodialysis over high flux hemodialysis for serum FLC removal in multiple myeloma on renal replacement therapy.During four hours of high cut-off hemodialysis,albumin loss can be effectively prevented by intravenous administration of 10 g albumin.
format Article
id doaj-art-3715ced44c824f449b66af0df1e58f45
institution OA Journals
issn 1671-2390
language zho
publishDate 2018-01-01
publisher Editorial Department of Journal of Clinical Nephrology
record_format Article
series Linchuang shenzangbing zazhi
spelling doaj-art-3715ced44c824f449b66af0df1e58f452025-08-20T01:51:10ZzhoEditorial Department of Journal of Clinical NephrologyLinchuang shenzangbing zazhi1671-23902018-01-01303357915994High cut-off hemodialysis vs. high flux hemodialysis for free light chain removal: a case report and literature reviewXU Feng-boSUN YiXUE FeiObjective To compare the high cut-off hemodialysis with high flux hemodialysis for free light chain removal,and to review literatures concerned. Methods A male aged59 was admitted due to " fatigue more than one year,aggravated two days". He felt fatigue one year ago and was diagnosed as multiple myeloma by bone marrow biopsy and increased free light chain. Then partial remission was achieved by thalidomide,adriamcin and dexamethasone. One week before,he felt weakness and chest pain,then a decrease in hemoglobin and acute renal failure were found,which was considered the recurrence of multiple myeloma. Cyclophosphamide,doxorubicin and dexamethasone chemotherapy was started. When the creatinine up to 611μmol/L,the hemodialysis treatment began. He received two times high flux hemodialysis( Fresenius FX60) first,then three times high cut-off hemodialysis( HCO2100). Time was four h and ultrafiltration was set at 0. 5 kg. Human albumin 10 g was replenished at high flux hemodialysis for 3. 5 h. The levels of serum FLCλ were detected by particle enhanced turbidimetric immunoassay,and those of serum albumin by automatic biochemical immunoassay before and after treatment.Results After two times high flux hemodialysis,serum levels of FLCλ were decreasedfrom 45. 9 to 36. 4 mg/L,and those of albumin changed from 31. 9 to 32. 7 mg/L respectively.After three times high cut-off hemodialysis,serum levels of FLC λ decreased from 42. 3 to 32. 1 mg/L,and those of albumin were decreased from 33 to 28 mg/L( 10 g albumin was added in each high cut-off hemodialysis). Conclusions We didn’t find the superiority of high cut-off hemodialysis over high flux hemodialysis for serum FLC removal in multiple myeloma on renal replacement therapy.During four hours of high cut-off hemodialysis,albumin loss can be effectively prevented by intravenous administration of 10 g albumin.http://www.lcszb.com/thesisDetails?columnId=57915994&Fpath=home&index=0Free light chainHigh cut-off hemodialysisHigh flux hemodialysis
spellingShingle XU Feng-bo
SUN Yi
XUE Fei
High cut-off hemodialysis vs. high flux hemodialysis for free light chain removal: a case report and literature review
Linchuang shenzangbing zazhi
Free light chain
High cut-off hemodialysis
High flux hemodialysis
title High cut-off hemodialysis vs. high flux hemodialysis for free light chain removal: a case report and literature review
title_full High cut-off hemodialysis vs. high flux hemodialysis for free light chain removal: a case report and literature review
title_fullStr High cut-off hemodialysis vs. high flux hemodialysis for free light chain removal: a case report and literature review
title_full_unstemmed High cut-off hemodialysis vs. high flux hemodialysis for free light chain removal: a case report and literature review
title_short High cut-off hemodialysis vs. high flux hemodialysis for free light chain removal: a case report and literature review
title_sort high cut off hemodialysis vs high flux hemodialysis for free light chain removal a case report and literature review
topic Free light chain
High cut-off hemodialysis
High flux hemodialysis
url http://www.lcszb.com/thesisDetails?columnId=57915994&Fpath=home&index=0
work_keys_str_mv AT xufengbo highcutoffhemodialysisvshighfluxhemodialysisforfreelightchainremovalacasereportandliteraturereview
AT sunyi highcutoffhemodialysisvshighfluxhemodialysisforfreelightchainremovalacasereportandliteraturereview
AT xuefei highcutoffhemodialysisvshighfluxhemodialysisforfreelightchainremovalacasereportandliteraturereview