Fault Tolerant Operation of ISOP Multicell Dc-Dc Converter Using Active Gate Controlled SiC Protection Switch
An active gate controlled semiconductor protection switch using SiC-MOSFET is proposed to achieve the fault tolerant operation of ISOP (Input Series and Output Parallel) connected multicell dc-dc converter. The SiC-MOSFET with high temperature capability simplifies the configuration of the protectio...
Saved in:
| Main Authors: | , , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Wiley
2016-01-01
|
| Series: | Journal of Engineering |
| Online Access: | http://dx.doi.org/10.1155/2016/7345232 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1850216606944198656 |
|---|---|
| author | Yusuke Hayashi Yoshikatsu Matsugaki Tamotsu Ninomiya |
| author_facet | Yusuke Hayashi Yoshikatsu Matsugaki Tamotsu Ninomiya |
| author_sort | Yusuke Hayashi |
| collection | DOAJ |
| description | An active gate controlled semiconductor protection switch using SiC-MOSFET is proposed to achieve the fault tolerant operation of ISOP (Input Series and Output Parallel) connected multicell dc-dc converter. The SiC-MOSFET with high temperature capability simplifies the configuration of the protection circuit, and its on-resistance control by the active gate controller realizes the smooth protection without the voltage and the current surges. The first laboratory prototype of the protection switch is fabricated by using a SiC-MOSFET with a high frequency buck chopper for the active gate controller. The effectiveness of the proposed protection switch is verified, taking the impact of the volume reduction into account. |
| format | Article |
| id | doaj-art-360e335baf464c9ba30fda1452756d85 |
| institution | OA Journals |
| issn | 2314-4904 2314-4912 |
| language | English |
| publishDate | 2016-01-01 |
| publisher | Wiley |
| record_format | Article |
| series | Journal of Engineering |
| spelling | doaj-art-360e335baf464c9ba30fda1452756d852025-08-20T02:08:15ZengWileyJournal of Engineering2314-49042314-49122016-01-01201610.1155/2016/73452327345232Fault Tolerant Operation of ISOP Multicell Dc-Dc Converter Using Active Gate Controlled SiC Protection SwitchYusuke Hayashi0Yoshikatsu Matsugaki1Tamotsu Ninomiya2Green Electronics Research Institute, Kitakyushu (GRIK), 1-8-409 Hibikino, Wakamatsu-ku, Kitakyushu, Fukuoka 808-0135, JapanGreen Electronics Research Institute, Kitakyushu (GRIK), 1-8-409 Hibikino, Wakamatsu-ku, Kitakyushu, Fukuoka 808-0135, JapanGreen Electronics Research Institute, Kitakyushu (GRIK), 1-8-409 Hibikino, Wakamatsu-ku, Kitakyushu, Fukuoka 808-0135, JapanAn active gate controlled semiconductor protection switch using SiC-MOSFET is proposed to achieve the fault tolerant operation of ISOP (Input Series and Output Parallel) connected multicell dc-dc converter. The SiC-MOSFET with high temperature capability simplifies the configuration of the protection circuit, and its on-resistance control by the active gate controller realizes the smooth protection without the voltage and the current surges. The first laboratory prototype of the protection switch is fabricated by using a SiC-MOSFET with a high frequency buck chopper for the active gate controller. The effectiveness of the proposed protection switch is verified, taking the impact of the volume reduction into account.http://dx.doi.org/10.1155/2016/7345232 |
| spellingShingle | Yusuke Hayashi Yoshikatsu Matsugaki Tamotsu Ninomiya Fault Tolerant Operation of ISOP Multicell Dc-Dc Converter Using Active Gate Controlled SiC Protection Switch Journal of Engineering |
| title | Fault Tolerant Operation of ISOP Multicell Dc-Dc Converter Using Active Gate Controlled SiC Protection Switch |
| title_full | Fault Tolerant Operation of ISOP Multicell Dc-Dc Converter Using Active Gate Controlled SiC Protection Switch |
| title_fullStr | Fault Tolerant Operation of ISOP Multicell Dc-Dc Converter Using Active Gate Controlled SiC Protection Switch |
| title_full_unstemmed | Fault Tolerant Operation of ISOP Multicell Dc-Dc Converter Using Active Gate Controlled SiC Protection Switch |
| title_short | Fault Tolerant Operation of ISOP Multicell Dc-Dc Converter Using Active Gate Controlled SiC Protection Switch |
| title_sort | fault tolerant operation of isop multicell dc dc converter using active gate controlled sic protection switch |
| url | http://dx.doi.org/10.1155/2016/7345232 |
| work_keys_str_mv | AT yusukehayashi faulttolerantoperationofisopmulticelldcdcconverterusingactivegatecontrolledsicprotectionswitch AT yoshikatsumatsugaki faulttolerantoperationofisopmulticelldcdcconverterusingactivegatecontrolledsicprotectionswitch AT tamotsuninomiya faulttolerantoperationofisopmulticelldcdcconverterusingactivegatecontrolledsicprotectionswitch |