A Novel “Slit Side View” Method to Evaluate Fluid Dynamics during Phacoemulsification

Due to recent technical advances in cataract surgeries, there has been a significant improvement in the safety and surgical outcomes of phacoemulsification. However, the corneal endothelium can be damaged during phacoemulsification by multiple factors. Therefore, we used a slit lamp to analyze the f...

Full description

Saved in:
Bibliographic Details
Main Authors: Hisaharu Suzuki, Tsutomu Igarashi, Toshihiko Shiwa, Hiroshi Takahashi
Format: Article
Language:English
Published: Wiley 2018-01-01
Series:Journal of Ophthalmology
Online Access:http://dx.doi.org/10.1155/2018/5027238
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832562935539433472
author Hisaharu Suzuki
Tsutomu Igarashi
Toshihiko Shiwa
Hiroshi Takahashi
author_facet Hisaharu Suzuki
Tsutomu Igarashi
Toshihiko Shiwa
Hiroshi Takahashi
author_sort Hisaharu Suzuki
collection DOAJ
description Due to recent technical advances in cataract surgeries, there has been a significant improvement in the safety and surgical outcomes of phacoemulsification. However, the corneal endothelium can be damaged during phacoemulsification by multiple factors. Therefore, we used a slit lamp to analyze the fluid dynamics of ophthalmic viscosurgical devices (OVDs) in the anterior chamber during phacoemulsification. In this experimental study, extracted porcine eyes were injected with OVDs stained with fluorescein through a side port of the eye and then fixed on a slit lamp microscope. After inserting a phaco tip, phacoemulsification simulation was then performed on the iris plane. Subsequent movements of OVDs in the anterior chamber were observed during the procedure by using a slit lamp microscope. Aspiration and removal of cohesive OVDs from the inside of the anterior chamber occurred within a few seconds after the ultrasonic vibration. Aspiration of dispersive OVDs occurred gradually, with some of the OVDs remaining on the side of the anterior chamber side in an irregular shape. This shape enabled the OVD to trap the air, thereby preventing the air from directly touching the corneal endothelium. Viscoadaptive OVDs remained inside the anterior chamber as a lump, with the infusion solution flowing between the corneal endothelium and the OVD, thus leading to the eventual aspiration of the OVD. Viscous dispersive OVDs remained as a lump between the corneal endothelium and the phaco tip. However, once the infusion solution flowed between the cornea and the OVD, the OVD detached from the corneal endothelium, indicating that this type would likely be aspirated and removed. This method, termed the “slit side view,” enables viewing of the movement of OVDs during surgery, as well as observation of the fluid dynamics in the anterior chamber.
format Article
id doaj-art-350cbb0695bf49be9f767672be5cf14a
institution Kabale University
issn 2090-004X
2090-0058
language English
publishDate 2018-01-01
publisher Wiley
record_format Article
series Journal of Ophthalmology
spelling doaj-art-350cbb0695bf49be9f767672be5cf14a2025-02-03T01:21:18ZengWileyJournal of Ophthalmology2090-004X2090-00582018-01-01201810.1155/2018/50272385027238A Novel “Slit Side View” Method to Evaluate Fluid Dynamics during PhacoemulsificationHisaharu Suzuki0Tsutomu Igarashi1Toshihiko Shiwa2Hiroshi Takahashi3Department of Ophthalmology, Nippon Medical School Musashikosugi Hospital, 1-396 Kosugi-cho, Nakahara-ku, Kawasaki City, Kanagawa 211-8533, JapanDepartment of Ophthalmology, Nippon Medical School, 1-1-5 Sendagi, Bunkyo-ku, Tokyo 113-8603, JapanDepartment of Ophthalmology, Nippon Medical School, 1-1-5 Sendagi, Bunkyo-ku, Tokyo 113-8603, JapanDepartment of Ophthalmology, Nippon Medical School, 1-1-5 Sendagi, Bunkyo-ku, Tokyo 113-8603, JapanDue to recent technical advances in cataract surgeries, there has been a significant improvement in the safety and surgical outcomes of phacoemulsification. However, the corneal endothelium can be damaged during phacoemulsification by multiple factors. Therefore, we used a slit lamp to analyze the fluid dynamics of ophthalmic viscosurgical devices (OVDs) in the anterior chamber during phacoemulsification. In this experimental study, extracted porcine eyes were injected with OVDs stained with fluorescein through a side port of the eye and then fixed on a slit lamp microscope. After inserting a phaco tip, phacoemulsification simulation was then performed on the iris plane. Subsequent movements of OVDs in the anterior chamber were observed during the procedure by using a slit lamp microscope. Aspiration and removal of cohesive OVDs from the inside of the anterior chamber occurred within a few seconds after the ultrasonic vibration. Aspiration of dispersive OVDs occurred gradually, with some of the OVDs remaining on the side of the anterior chamber side in an irregular shape. This shape enabled the OVD to trap the air, thereby preventing the air from directly touching the corneal endothelium. Viscoadaptive OVDs remained inside the anterior chamber as a lump, with the infusion solution flowing between the corneal endothelium and the OVD, thus leading to the eventual aspiration of the OVD. Viscous dispersive OVDs remained as a lump between the corneal endothelium and the phaco tip. However, once the infusion solution flowed between the cornea and the OVD, the OVD detached from the corneal endothelium, indicating that this type would likely be aspirated and removed. This method, termed the “slit side view,” enables viewing of the movement of OVDs during surgery, as well as observation of the fluid dynamics in the anterior chamber.http://dx.doi.org/10.1155/2018/5027238
spellingShingle Hisaharu Suzuki
Tsutomu Igarashi
Toshihiko Shiwa
Hiroshi Takahashi
A Novel “Slit Side View” Method to Evaluate Fluid Dynamics during Phacoemulsification
Journal of Ophthalmology
title A Novel “Slit Side View” Method to Evaluate Fluid Dynamics during Phacoemulsification
title_full A Novel “Slit Side View” Method to Evaluate Fluid Dynamics during Phacoemulsification
title_fullStr A Novel “Slit Side View” Method to Evaluate Fluid Dynamics during Phacoemulsification
title_full_unstemmed A Novel “Slit Side View” Method to Evaluate Fluid Dynamics during Phacoemulsification
title_short A Novel “Slit Side View” Method to Evaluate Fluid Dynamics during Phacoemulsification
title_sort novel slit side view method to evaluate fluid dynamics during phacoemulsification
url http://dx.doi.org/10.1155/2018/5027238
work_keys_str_mv AT hisaharusuzuki anovelslitsideviewmethodtoevaluatefluiddynamicsduringphacoemulsification
AT tsutomuigarashi anovelslitsideviewmethodtoevaluatefluiddynamicsduringphacoemulsification
AT toshihikoshiwa anovelslitsideviewmethodtoevaluatefluiddynamicsduringphacoemulsification
AT hiroshitakahashi anovelslitsideviewmethodtoevaluatefluiddynamicsduringphacoemulsification
AT hisaharusuzuki novelslitsideviewmethodtoevaluatefluiddynamicsduringphacoemulsification
AT tsutomuigarashi novelslitsideviewmethodtoevaluatefluiddynamicsduringphacoemulsification
AT toshihikoshiwa novelslitsideviewmethodtoevaluatefluiddynamicsduringphacoemulsification
AT hiroshitakahashi novelslitsideviewmethodtoevaluatefluiddynamicsduringphacoemulsification