The optimization of an accomodation in the thoracic cavity child the axial pump don-3 (the mathematical model research)

We have developed and tested a technique for constructing 3D models of the chest and thoracic cavity organs. Due to the obtained results, the mathematical model  was successfully used in the development of classification of variants of placement  of implantable auxiliary circulation systems, and als...

Full description

Saved in:
Bibliographic Details
Main Authors: V. A. Kozlov, O. Yu. Dmitrieva, G. P. Itkin, A. S. Ivanov, A. P. Kuleshov, E. A. Volkova, T. N. Govorova
Format: Article
Language:Russian
Published: Federal Research Center of Transplantology and Artificial Organs named after V.I.Shumakov 2018-09-01
Series:Вестник трансплантологии и искусственных органов
Subjects:
Online Access:https://journal.transpl.ru/vtio/article/view/910
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849774663038664704
author V. A. Kozlov
O. Yu. Dmitrieva
G. P. Itkin
A. S. Ivanov
A. P. Kuleshov
E. A. Volkova
T. N. Govorova
author_facet V. A. Kozlov
O. Yu. Dmitrieva
G. P. Itkin
A. S. Ivanov
A. P. Kuleshov
E. A. Volkova
T. N. Govorova
author_sort V. A. Kozlov
collection DOAJ
description We have developed and tested a technique for constructing 3D models of the chest and thoracic cavity organs. Due to the obtained results, the mathematical model  was successfully used in the development of classification of variants of placement  of implantable auxiliary circulation systems, and also for building 3D models for  other purposes. In particular, the patients were graded according to the variants of  placing the children’s axial pump DON-3 inside the patient’s chest cavity. Based on  the data, the first fitting of the DON-3 pump was performed on a patient aged 7 years.
format Article
id doaj-art-34943a5f96b34fd6a4cf90ea2456332d
institution DOAJ
issn 1995-1191
language Russian
publishDate 2018-09-01
publisher Federal Research Center of Transplantology and Artificial Organs named after V.I.Shumakov
record_format Article
series Вестник трансплантологии и искусственных органов
spelling doaj-art-34943a5f96b34fd6a4cf90ea2456332d2025-08-20T03:01:38ZrusFederal Research Center of Transplantology and Artificial Organs named after V.I.ShumakovВестник трансплантологии и искусственных органов1995-11912018-09-01203404410.15825/1995-1191-2018-3-40-44719The optimization of an accomodation in the thoracic cavity child the axial pump don-3 (the mathematical model research)V. A. Kozlov0O. Yu. Dmitrieva1G. P. Itkin2A. S. Ivanov3A. P. Kuleshov4E. A. Volkova5T. N. Govorova6V.I. Shumakov National Medical Research Center of Transplantology and Artificial Organs of the Ministry of Healthcare of the Russian Federation Moscow Institute of Physics and Technology (State University), Department of physics of living systemsV.I. Shumakov National Medical Research Center of Transplantology and Artificial Organs of the Ministry of Healthcare of the Russian FederationV.I. Shumakov National Medical Research Center of Transplantology and Artificial Organs of the Ministry of Healthcare of the Russian Federation Moscow Institute of Physics and Technology (State University), Department of physics of living systemsV.I. Shumakov National Medical Research Center of Transplantology and Artificial Organs of the Ministry of Healthcare of the Russian FederationV.I. Shumakov National Medical Research Center of Transplantology and Artificial Organs of the Ministry of Healthcare of the Russian FederationV.I. Shumakov National Medical Research Center of Transplantology and Artificial Organs of the Ministry of Healthcare of the Russian FederationV.I. Shumakov National Medical Research Center of Transplantology and Artificial Organs of the Ministry of Healthcare of the Russian FederationWe have developed and tested a technique for constructing 3D models of the chest and thoracic cavity organs. Due to the obtained results, the mathematical model  was successfully used in the development of classification of variants of placement  of implantable auxiliary circulation systems, and also for building 3D models for  other purposes. In particular, the patients were graded according to the variants of  placing the children’s axial pump DON-3 inside the patient’s chest cavity. Based on  the data, the first fitting of the DON-3 pump was performed on a patient aged 7 years.https://journal.transpl.ru/vtio/article/view/910children’s axial pumpmathematical modelingct scanlocation of the axial pump
spellingShingle V. A. Kozlov
O. Yu. Dmitrieva
G. P. Itkin
A. S. Ivanov
A. P. Kuleshov
E. A. Volkova
T. N. Govorova
The optimization of an accomodation in the thoracic cavity child the axial pump don-3 (the mathematical model research)
Вестник трансплантологии и искусственных органов
children’s axial pump
mathematical modeling
ct scan
location of the axial pump
title The optimization of an accomodation in the thoracic cavity child the axial pump don-3 (the mathematical model research)
title_full The optimization of an accomodation in the thoracic cavity child the axial pump don-3 (the mathematical model research)
title_fullStr The optimization of an accomodation in the thoracic cavity child the axial pump don-3 (the mathematical model research)
title_full_unstemmed The optimization of an accomodation in the thoracic cavity child the axial pump don-3 (the mathematical model research)
title_short The optimization of an accomodation in the thoracic cavity child the axial pump don-3 (the mathematical model research)
title_sort optimization of an accomodation in the thoracic cavity child the axial pump don 3 the mathematical model research
topic children’s axial pump
mathematical modeling
ct scan
location of the axial pump
url https://journal.transpl.ru/vtio/article/view/910
work_keys_str_mv AT vakozlov theoptimizationofanaccomodationinthethoraciccavitychildtheaxialpumpdon3themathematicalmodelresearch
AT oyudmitrieva theoptimizationofanaccomodationinthethoraciccavitychildtheaxialpumpdon3themathematicalmodelresearch
AT gpitkin theoptimizationofanaccomodationinthethoraciccavitychildtheaxialpumpdon3themathematicalmodelresearch
AT asivanov theoptimizationofanaccomodationinthethoraciccavitychildtheaxialpumpdon3themathematicalmodelresearch
AT apkuleshov theoptimizationofanaccomodationinthethoraciccavitychildtheaxialpumpdon3themathematicalmodelresearch
AT eavolkova theoptimizationofanaccomodationinthethoraciccavitychildtheaxialpumpdon3themathematicalmodelresearch
AT tngovorova theoptimizationofanaccomodationinthethoraciccavitychildtheaxialpumpdon3themathematicalmodelresearch
AT vakozlov optimizationofanaccomodationinthethoraciccavitychildtheaxialpumpdon3themathematicalmodelresearch
AT oyudmitrieva optimizationofanaccomodationinthethoraciccavitychildtheaxialpumpdon3themathematicalmodelresearch
AT gpitkin optimizationofanaccomodationinthethoraciccavitychildtheaxialpumpdon3themathematicalmodelresearch
AT asivanov optimizationofanaccomodationinthethoraciccavitychildtheaxialpumpdon3themathematicalmodelresearch
AT apkuleshov optimizationofanaccomodationinthethoraciccavitychildtheaxialpumpdon3themathematicalmodelresearch
AT eavolkova optimizationofanaccomodationinthethoraciccavitychildtheaxialpumpdon3themathematicalmodelresearch
AT tngovorova optimizationofanaccomodationinthethoraciccavitychildtheaxialpumpdon3themathematicalmodelresearch