Analysis of Force Characteristics in Foot Operations Using Isometric Device

The lower limbs, which have multiple degrees of freedom, can be used to manipulate a robot or an object in a virtual environment. Such manipulation can be achieved by measuring the direction of force exerted by the lower limbs using an isometric device equipped with a force sensor. This study experi...

Full description

Saved in:
Bibliographic Details
Main Authors: Yang Li, Rintaro Iio, Shoun Nishioka, Tatsuro Terakawa, Masaharu Komori
Format: Article
Language:English
Published: IEEE 2025-01-01
Series:IEEE Access
Subjects:
Online Access:https://ieeexplore.ieee.org/document/10970039/
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850170875556397056
author Yang Li
Rintaro Iio
Shoun Nishioka
Tatsuro Terakawa
Masaharu Komori
author_facet Yang Li
Rintaro Iio
Shoun Nishioka
Tatsuro Terakawa
Masaharu Komori
author_sort Yang Li
collection DOAJ
description The lower limbs, which have multiple degrees of freedom, can be used to manipulate a robot or an object in a virtual environment. Such manipulation can be achieved by measuring the direction of force exerted by the lower limbs using an isometric device equipped with a force sensor. This study experimentally investigates the differences between the intended and actual directions of force exerted by the lower limbs when operating an isometric device. The results of experiments conducted using 48 force directions indicate that there are five prominent characteristics in the differences between the intended and actual force directions. For example, when the intended force is the backward direction, an upward force component is also generated. In addition, we conducted a musculoskeletal analysis to analyze the causes of the differences between the intended and actual force directions and calculated the metabolic energy consumption (<inline-formula> <tex-math notation="LaTeX">$E_{m}$ </tex-math></inline-formula>). The results confirm that some force directions result in lower <inline-formula> <tex-math notation="LaTeX">$E_{m}$ </tex-math></inline-formula> and show that the actual force directions measured in the experiment tend to be close to the force directions that resulted in lower <inline-formula> <tex-math notation="LaTeX">$E_{m}$ </tex-math></inline-formula>. This suggests that reducing <inline-formula> <tex-math notation="LaTeX">$E_{m}$ </tex-math></inline-formula> is one of the causes of the differences between the intended and actual force directions.
format Article
id doaj-art-34458799c19d4e678cc68fe48e6d72f4
institution OA Journals
issn 2169-3536
language English
publishDate 2025-01-01
publisher IEEE
record_format Article
series IEEE Access
spelling doaj-art-34458799c19d4e678cc68fe48e6d72f42025-08-20T02:20:23ZengIEEEIEEE Access2169-35362025-01-0113711977121310.1109/ACCESS.2025.356237710970039Analysis of Force Characteristics in Foot Operations Using Isometric DeviceYang Li0https://orcid.org/0000-0002-9859-6230Rintaro Iio1Shoun Nishioka2Tatsuro Terakawa3https://orcid.org/0000-0002-9418-3156Masaharu Komori4https://orcid.org/0000-0001-8696-8167Department of Mechanical Engineering and Science, Kyoto University, Kyoto, JapanDepartment of Mechanical Engineering and Science, Kyoto University, Kyoto, JapanDepartment of Mechanical Engineering and Science, Kyoto University, Kyoto, JapanDepartment of Mechanical Engineering and Science, Kyoto University, Kyoto, JapanDepartment of Mechanical Engineering and Science, Kyoto University, Kyoto, JapanThe lower limbs, which have multiple degrees of freedom, can be used to manipulate a robot or an object in a virtual environment. Such manipulation can be achieved by measuring the direction of force exerted by the lower limbs using an isometric device equipped with a force sensor. This study experimentally investigates the differences between the intended and actual directions of force exerted by the lower limbs when operating an isometric device. The results of experiments conducted using 48 force directions indicate that there are five prominent characteristics in the differences between the intended and actual force directions. For example, when the intended force is the backward direction, an upward force component is also generated. In addition, we conducted a musculoskeletal analysis to analyze the causes of the differences between the intended and actual force directions and calculated the metabolic energy consumption (<inline-formula> <tex-math notation="LaTeX">$E_{m}$ </tex-math></inline-formula>). The results confirm that some force directions result in lower <inline-formula> <tex-math notation="LaTeX">$E_{m}$ </tex-math></inline-formula> and show that the actual force directions measured in the experiment tend to be close to the force directions that resulted in lower <inline-formula> <tex-math notation="LaTeX">$E_{m}$ </tex-math></inline-formula>. This suggests that reducing <inline-formula> <tex-math notation="LaTeX">$E_{m}$ </tex-math></inline-formula> is one of the causes of the differences between the intended and actual force directions.https://ieeexplore.ieee.org/document/10970039/Foot operationlower limbisometric deviceforce characteristics
spellingShingle Yang Li
Rintaro Iio
Shoun Nishioka
Tatsuro Terakawa
Masaharu Komori
Analysis of Force Characteristics in Foot Operations Using Isometric Device
IEEE Access
Foot operation
lower limb
isometric device
force characteristics
title Analysis of Force Characteristics in Foot Operations Using Isometric Device
title_full Analysis of Force Characteristics in Foot Operations Using Isometric Device
title_fullStr Analysis of Force Characteristics in Foot Operations Using Isometric Device
title_full_unstemmed Analysis of Force Characteristics in Foot Operations Using Isometric Device
title_short Analysis of Force Characteristics in Foot Operations Using Isometric Device
title_sort analysis of force characteristics in foot operations using isometric device
topic Foot operation
lower limb
isometric device
force characteristics
url https://ieeexplore.ieee.org/document/10970039/
work_keys_str_mv AT yangli analysisofforcecharacteristicsinfootoperationsusingisometricdevice
AT rintaroiio analysisofforcecharacteristicsinfootoperationsusingisometricdevice
AT shounnishioka analysisofforcecharacteristicsinfootoperationsusingisometricdevice
AT tatsuroterakawa analysisofforcecharacteristicsinfootoperationsusingisometricdevice
AT masaharukomori analysisofforcecharacteristicsinfootoperationsusingisometricdevice