Megavoltage X-Ray Imaging Based on Cerenkov Effect: A New Application of Optical Fibres to Radiation Therapy

A Monte Carlo simulation was used to study imaging and dosimetric characteristics of a novel design of megavoltage (MV) X-ray detectors for radiotherapy applications. The new design uses Cerenkov effect to convert X-ray energy absorbed in optical fibres into light for MV X-ray imaging. The proposed...

Full description

Saved in:
Bibliographic Details
Main Authors: A. Teymurazyan, G. Pang
Format: Article
Language:English
Published: Wiley 2012-01-01
Series:International Journal of Optics
Online Access:http://dx.doi.org/10.1155/2012/724024
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850157096041971712
author A. Teymurazyan
G. Pang
author_facet A. Teymurazyan
G. Pang
author_sort A. Teymurazyan
collection DOAJ
description A Monte Carlo simulation was used to study imaging and dosimetric characteristics of a novel design of megavoltage (MV) X-ray detectors for radiotherapy applications. The new design uses Cerenkov effect to convert X-ray energy absorbed in optical fibres into light for MV X-ray imaging. The proposed detector consists of a matrix of optical fibres aligned with the incident X rays and coupled to an active matrix flat-panel imager (AMFPI) for image readout. Properties, such as modulation transfer function, detection quantum efficiency (DQE), and energy response of the detector, were investigated. It has been shown that the proposed detector can have a zero-frequency DQE more than an order of magnitude higher than that of current electronic portal imaging device (EPID) systems and yet a spatial resolution comparable to that of video-based EPIDs. The proposed detector is also less sensitive to scattered X rays from patients than current EPIDs.
format Article
id doaj-art-3377ecdc3a084fb4a1110dbb878dc3f4
institution OA Journals
issn 1687-9384
1687-9392
language English
publishDate 2012-01-01
publisher Wiley
record_format Article
series International Journal of Optics
spelling doaj-art-3377ecdc3a084fb4a1110dbb878dc3f42025-08-20T02:24:17ZengWileyInternational Journal of Optics1687-93841687-93922012-01-01201210.1155/2012/724024724024Megavoltage X-Ray Imaging Based on Cerenkov Effect: A New Application of Optical Fibres to Radiation TherapyA. Teymurazyan0G. Pang1Imaging Research, Sunnybrook Health Sciences Centre and Department of Medical Biophysics, University of Toronto, Toronto, ON, M4N 3M5, CanadaImaging Research, Sunnybrook Health Sciences Centre and Department of Medical Biophysics, University of Toronto, Toronto, ON, M4N 3M5, CanadaA Monte Carlo simulation was used to study imaging and dosimetric characteristics of a novel design of megavoltage (MV) X-ray detectors for radiotherapy applications. The new design uses Cerenkov effect to convert X-ray energy absorbed in optical fibres into light for MV X-ray imaging. The proposed detector consists of a matrix of optical fibres aligned with the incident X rays and coupled to an active matrix flat-panel imager (AMFPI) for image readout. Properties, such as modulation transfer function, detection quantum efficiency (DQE), and energy response of the detector, were investigated. It has been shown that the proposed detector can have a zero-frequency DQE more than an order of magnitude higher than that of current electronic portal imaging device (EPID) systems and yet a spatial resolution comparable to that of video-based EPIDs. The proposed detector is also less sensitive to scattered X rays from patients than current EPIDs.http://dx.doi.org/10.1155/2012/724024
spellingShingle A. Teymurazyan
G. Pang
Megavoltage X-Ray Imaging Based on Cerenkov Effect: A New Application of Optical Fibres to Radiation Therapy
International Journal of Optics
title Megavoltage X-Ray Imaging Based on Cerenkov Effect: A New Application of Optical Fibres to Radiation Therapy
title_full Megavoltage X-Ray Imaging Based on Cerenkov Effect: A New Application of Optical Fibres to Radiation Therapy
title_fullStr Megavoltage X-Ray Imaging Based on Cerenkov Effect: A New Application of Optical Fibres to Radiation Therapy
title_full_unstemmed Megavoltage X-Ray Imaging Based on Cerenkov Effect: A New Application of Optical Fibres to Radiation Therapy
title_short Megavoltage X-Ray Imaging Based on Cerenkov Effect: A New Application of Optical Fibres to Radiation Therapy
title_sort megavoltage x ray imaging based on cerenkov effect a new application of optical fibres to radiation therapy
url http://dx.doi.org/10.1155/2012/724024
work_keys_str_mv AT ateymurazyan megavoltagexrayimagingbasedoncerenkoveffectanewapplicationofopticalfibrestoradiationtherapy
AT gpang megavoltagexrayimagingbasedoncerenkoveffectanewapplicationofopticalfibrestoradiationtherapy