Assessment of Bacterial Load in Polyethylene Terephthalate (PET) Bottled Water Marketed in Kathmandu Valley, Nepal
In recent years, we are having mixed feelings regarding the use of polyethylene terephthalate (PET) bottles for storing water. The aim of this study is to determine any associations between bacterial load and the physical condition of the water bottle. For this study, bottled water was purchased, an...
Saved in:
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2021-01-01
|
Series: | International Journal of Polymer Science |
Online Access: | http://dx.doi.org/10.1155/2021/6681249 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832559753438429184 |
---|---|
author | Bikram Gautam Gaumani Gyanwali David Wayne Ussery |
author_facet | Bikram Gautam Gaumani Gyanwali David Wayne Ussery |
author_sort | Bikram Gautam |
collection | DOAJ |
description | In recent years, we are having mixed feelings regarding the use of polyethylene terephthalate (PET) bottles for storing water. The aim of this study is to determine any associations between bacterial load and the physical condition of the water bottle. For this study, bottled water was purchased, and parameters like pH, electrical conductivity (EC), total dissolved solids (TDS), heterotrophic plate count (HPC), total coliform count, and Pseudomonas spp. count were determined as per the American Public Health Association, 2005. The pH value of water samples tested ranged from 5.2 to 6.8. The majority of samples (96%) were found to contain pH values that were unacceptable as per the Department of Food Technology and Quality Control (DFTQC) guideline. Value of electrical conductivity (EC) ranged from 5 to 199 μS/cm. HPC revealed that, out of 100 samples, 48 (48%) samples were found to be acceptable as per the DFTQC guideline value (<25 cfu/mL). Among 100 samples, Pseudomonas spp. was found to be present in 23% of bottled water. Acidic pH and elevated concentrations of TDS and EC may lead to the survival of extremophiles present in HPC which may lead to degradation of PET. Extremophile bacteria that survive in bottled water for a long time rely on several survival mechanisms including evolutionary development (evo-devo) and solely survive on complex polymers like PET. |
format | Article |
id | doaj-art-335a8b0752194f5eaed03086e79361ac |
institution | Kabale University |
issn | 1687-9422 1687-9430 |
language | English |
publishDate | 2021-01-01 |
publisher | Wiley |
record_format | Article |
series | International Journal of Polymer Science |
spelling | doaj-art-335a8b0752194f5eaed03086e79361ac2025-02-03T01:29:18ZengWileyInternational Journal of Polymer Science1687-94221687-94302021-01-01202110.1155/2021/66812496681249Assessment of Bacterial Load in Polyethylene Terephthalate (PET) Bottled Water Marketed in Kathmandu Valley, NepalBikram Gautam0Gaumani Gyanwali1David Wayne Ussery2Research Center for Applied Science and Technology (RECAST), T.U., Kritipur, NepalChemistry and Physical Sciences, University of Arkansas Rich Mountain, Arkansas, USADepartment of Biomedical Informatics, University of Arkansas for Medical Sciences, Arkansas, USAIn recent years, we are having mixed feelings regarding the use of polyethylene terephthalate (PET) bottles for storing water. The aim of this study is to determine any associations between bacterial load and the physical condition of the water bottle. For this study, bottled water was purchased, and parameters like pH, electrical conductivity (EC), total dissolved solids (TDS), heterotrophic plate count (HPC), total coliform count, and Pseudomonas spp. count were determined as per the American Public Health Association, 2005. The pH value of water samples tested ranged from 5.2 to 6.8. The majority of samples (96%) were found to contain pH values that were unacceptable as per the Department of Food Technology and Quality Control (DFTQC) guideline. Value of electrical conductivity (EC) ranged from 5 to 199 μS/cm. HPC revealed that, out of 100 samples, 48 (48%) samples were found to be acceptable as per the DFTQC guideline value (<25 cfu/mL). Among 100 samples, Pseudomonas spp. was found to be present in 23% of bottled water. Acidic pH and elevated concentrations of TDS and EC may lead to the survival of extremophiles present in HPC which may lead to degradation of PET. Extremophile bacteria that survive in bottled water for a long time rely on several survival mechanisms including evolutionary development (evo-devo) and solely survive on complex polymers like PET.http://dx.doi.org/10.1155/2021/6681249 |
spellingShingle | Bikram Gautam Gaumani Gyanwali David Wayne Ussery Assessment of Bacterial Load in Polyethylene Terephthalate (PET) Bottled Water Marketed in Kathmandu Valley, Nepal International Journal of Polymer Science |
title | Assessment of Bacterial Load in Polyethylene Terephthalate (PET) Bottled Water Marketed in Kathmandu Valley, Nepal |
title_full | Assessment of Bacterial Load in Polyethylene Terephthalate (PET) Bottled Water Marketed in Kathmandu Valley, Nepal |
title_fullStr | Assessment of Bacterial Load in Polyethylene Terephthalate (PET) Bottled Water Marketed in Kathmandu Valley, Nepal |
title_full_unstemmed | Assessment of Bacterial Load in Polyethylene Terephthalate (PET) Bottled Water Marketed in Kathmandu Valley, Nepal |
title_short | Assessment of Bacterial Load in Polyethylene Terephthalate (PET) Bottled Water Marketed in Kathmandu Valley, Nepal |
title_sort | assessment of bacterial load in polyethylene terephthalate pet bottled water marketed in kathmandu valley nepal |
url | http://dx.doi.org/10.1155/2021/6681249 |
work_keys_str_mv | AT bikramgautam assessmentofbacterialloadinpolyethyleneterephthalatepetbottledwatermarketedinkathmanduvalleynepal AT gaumanigyanwali assessmentofbacterialloadinpolyethyleneterephthalatepetbottledwatermarketedinkathmanduvalleynepal AT davidwayneussery assessmentofbacterialloadinpolyethyleneterephthalatepetbottledwatermarketedinkathmanduvalleynepal |