Challenges and Solution for Corrosion under Pipe Supports

Petrochemical facilities and refineries consist of many miles of above ground piping that transports product between processing and storage units. These pipes are either supported at ground level or in multi-story pipe racks on varying types and sizes of supporting structures. A common problem...

Full description

Saved in:
Bibliographic Details
Main Authors: Sachin Sajeev, Arun Nair
Format: Article
Language:deu
Published: NDT.net 2025-03-01
Series:e-Journal of Nondestructive Testing
Online Access:https://www.ndt.net/search/docs.php3?id=30837
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849728527353511936
author Sachin Sajeev
Arun Nair
author_facet Sachin Sajeev
Arun Nair
author_sort Sachin Sajeev
collection DOAJ
description Petrochemical facilities and refineries consist of many miles of above ground piping that transports product between processing and storage units. These pipes are either supported at ground level or in multi-story pipe racks on varying types and sizes of supporting structures. A common problem these structures create is corrosion and erosion at the junction between the pipe and the support, which reduces the remaining wall thickness of the pipe and compromises the integrity of the entire system. Corrosion Under Pipe Support (CUPS) also known as Touchpoint Corrosion is a widespread issue within the industry that has caused in-service leaks and ruptures. Crevice corrosion is the mechanism were by which CUPS are initiated in a pipeline. Water entrapment at metal to metal contact leads to crevice corrosion. Minimizing the area of contact between support and pipe is effective in reducing the CUPS. A solution for the quantitative measurement of CUPS is a major requirement of the industry. Visual Inspection can provide an indication of corrosion (product build-up) but it is significantly hampered by the lack of access to the critical areas. Line Lifting of a potentially corroded pipe from its support for direct examination is dangerous on live process lines. Hence it is necessary to use advanced NDT methods that can provide information on the severity of the CUPS without removal of the supports which would eliminate the need for a shutdown. CUPS is basically a hidden, inaccessible corrosion which cannot be quantified with simple NDT Techniques. GUL’s QSR-1 is a promising solution for the CUPS. Quantitative measurement of the corrosion is achievable with QSR-1. A study was done at our workshop with QSR-1 on a 10-inch pipe with artificial corrosion patches. Sizing capability for various defect orientation along the pipe circumference was also studied. The technology was used to inspect 20-inch cooling water header line for one of the prominent clients.
format Article
id doaj-art-32f3de268bd54f699aaf379b6fa84a41
institution DOAJ
issn 1435-4934
language deu
publishDate 2025-03-01
publisher NDT.net
record_format Article
series e-Journal of Nondestructive Testing
spelling doaj-art-32f3de268bd54f699aaf379b6fa84a412025-08-20T03:09:31ZdeuNDT.nete-Journal of Nondestructive Testing1435-49342025-03-0130310.58286/30837Challenges and Solution for Corrosion under Pipe SupportsSachin SajeevArun Nair Petrochemical facilities and refineries consist of many miles of above ground piping that transports product between processing and storage units. These pipes are either supported at ground level or in multi-story pipe racks on varying types and sizes of supporting structures. A common problem these structures create is corrosion and erosion at the junction between the pipe and the support, which reduces the remaining wall thickness of the pipe and compromises the integrity of the entire system. Corrosion Under Pipe Support (CUPS) also known as Touchpoint Corrosion is a widespread issue within the industry that has caused in-service leaks and ruptures. Crevice corrosion is the mechanism were by which CUPS are initiated in a pipeline. Water entrapment at metal to metal contact leads to crevice corrosion. Minimizing the area of contact between support and pipe is effective in reducing the CUPS. A solution for the quantitative measurement of CUPS is a major requirement of the industry. Visual Inspection can provide an indication of corrosion (product build-up) but it is significantly hampered by the lack of access to the critical areas. Line Lifting of a potentially corroded pipe from its support for direct examination is dangerous on live process lines. Hence it is necessary to use advanced NDT methods that can provide information on the severity of the CUPS without removal of the supports which would eliminate the need for a shutdown. CUPS is basically a hidden, inaccessible corrosion which cannot be quantified with simple NDT Techniques. GUL’s QSR-1 is a promising solution for the CUPS. Quantitative measurement of the corrosion is achievable with QSR-1. A study was done at our workshop with QSR-1 on a 10-inch pipe with artificial corrosion patches. Sizing capability for various defect orientation along the pipe circumference was also studied. The technology was used to inspect 20-inch cooling water header line for one of the prominent clients. https://www.ndt.net/search/docs.php3?id=30837
spellingShingle Sachin Sajeev
Arun Nair
Challenges and Solution for Corrosion under Pipe Supports
e-Journal of Nondestructive Testing
title Challenges and Solution for Corrosion under Pipe Supports
title_full Challenges and Solution for Corrosion under Pipe Supports
title_fullStr Challenges and Solution for Corrosion under Pipe Supports
title_full_unstemmed Challenges and Solution for Corrosion under Pipe Supports
title_short Challenges and Solution for Corrosion under Pipe Supports
title_sort challenges and solution for corrosion under pipe supports
url https://www.ndt.net/search/docs.php3?id=30837
work_keys_str_mv AT sachinsajeev challengesandsolutionforcorrosionunderpipesupports
AT arunnair challengesandsolutionforcorrosionunderpipesupports