Focused ion beam (FIB) prepared microtextured microneedle array capable of delivering drugs through punctured skin

Abstract Microtextured microneedles are tiny needle-like structures with micron-scale microtextures, and the drugs stored in the microtextures can be released after entering the skin to achieve the effect of precise drug delivery. In this study, the skin substitution model of Ogden’s hyperelastic mo...

Full description

Saved in:
Bibliographic Details
Main Authors: Yan Zhang, Zhaoqiang Chen, Wendong Wu, Chonghai Xu
Format: Article
Language:English
Published: Nature Portfolio 2024-12-01
Series:Scientific Reports
Subjects:
Online Access:https://doi.org/10.1038/s41598-024-83094-z
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850103411226181632
author Yan Zhang
Zhaoqiang Chen
Wendong Wu
Chonghai Xu
author_facet Yan Zhang
Zhaoqiang Chen
Wendong Wu
Chonghai Xu
author_sort Yan Zhang
collection DOAJ
description Abstract Microtextured microneedles are tiny needle-like structures with micron-scale microtextures, and the drugs stored in the microtextures can be released after entering the skin to achieve the effect of precise drug delivery. In this study, the skin substitution model of Ogden’s hyperelastic model and the microneedle array and microtexture models with different geometrical parameters were selected to simulate and analyse the flow of the microtexture microneedle arrays penetrating the skin by the finite-element method, and the length of the microneedles was determined to be 200 μm, the width 160 μm, and the value of the gaps was determined to be 420 μm. A four-pronged cone was chosen as the shape of microneedles, and a rectangle was chosen as the shape of the drug-carrying microneedle. The initial microneedle arrays were prepared by wet etching using monocrystalline silicon as the material due to its high mechanical strength, stability and good biocompatibility. The sputtering yield, energy loss and material damage of single crystal silicon materials during focused ion beam (FIB) processing were calculated using Monte Carlo method and found to have optimum removal efficiency and processing accuracy at 30 keV ion beam voltage. After the initial microneedle arrays were prepared using wet etching, microtextures were prepared on the microneedles with 30° inclination and 45° inclination using FIB technique with processing parameters of 30 keV and 60 nA. Biocompatibility tests showed a cell survival rate of 99.42% for the cell set containing the microneedle array, indicating that the microneedle array was non-toxic to the cells. The viscosity and contact angle of 5-fluorouracil, triamcinolone acetonide and tacrolimus were examined and it was learnt that tacrolimus had the highest viscosity and the lowest contact angle and the configured solution was able to be more present in the microtexture and was more stable and less susceptible to loss. The experiments of drug-carrying skin puncture mice showed that the stained area of tacrolimus was brighter and more uniformly distributed, the stained area of microtextured microneedles was larger than that of ordinary microneedles by 70.52%, the drug-carrying area was larger than the average area of ordinary microneedles by 105.09%, and the drug-carrying effect of microtextured microneedles with a horizontal inclination angle of 30° was more effective.
format Article
id doaj-art-323cd0fc3a3d4b16aff8ffc82dc094ec
institution DOAJ
issn 2045-2322
language English
publishDate 2024-12-01
publisher Nature Portfolio
record_format Article
series Scientific Reports
spelling doaj-art-323cd0fc3a3d4b16aff8ffc82dc094ec2025-08-20T02:39:34ZengNature PortfolioScientific Reports2045-23222024-12-0114112810.1038/s41598-024-83094-zFocused ion beam (FIB) prepared microtextured microneedle array capable of delivering drugs through punctured skinYan Zhang0Zhaoqiang Chen1Wendong Wu2Chonghai Xu3School of Mechanical Engineering, Qilu University of Technology (Shandong Academy of Sciences)School of Mechanical Engineering, Qilu University of Technology (Shandong Academy of Sciences)School of Mechanical Engineering, Qilu University of Technology (Shandong Academy of Sciences)School of Mechanical Engineering, Qilu University of Technology (Shandong Academy of Sciences)Abstract Microtextured microneedles are tiny needle-like structures with micron-scale microtextures, and the drugs stored in the microtextures can be released after entering the skin to achieve the effect of precise drug delivery. In this study, the skin substitution model of Ogden’s hyperelastic model and the microneedle array and microtexture models with different geometrical parameters were selected to simulate and analyse the flow of the microtexture microneedle arrays penetrating the skin by the finite-element method, and the length of the microneedles was determined to be 200 μm, the width 160 μm, and the value of the gaps was determined to be 420 μm. A four-pronged cone was chosen as the shape of microneedles, and a rectangle was chosen as the shape of the drug-carrying microneedle. The initial microneedle arrays were prepared by wet etching using monocrystalline silicon as the material due to its high mechanical strength, stability and good biocompatibility. The sputtering yield, energy loss and material damage of single crystal silicon materials during focused ion beam (FIB) processing were calculated using Monte Carlo method and found to have optimum removal efficiency and processing accuracy at 30 keV ion beam voltage. After the initial microneedle arrays were prepared using wet etching, microtextures were prepared on the microneedles with 30° inclination and 45° inclination using FIB technique with processing parameters of 30 keV and 60 nA. Biocompatibility tests showed a cell survival rate of 99.42% for the cell set containing the microneedle array, indicating that the microneedle array was non-toxic to the cells. The viscosity and contact angle of 5-fluorouracil, triamcinolone acetonide and tacrolimus were examined and it was learnt that tacrolimus had the highest viscosity and the lowest contact angle and the configured solution was able to be more present in the microtexture and was more stable and less susceptible to loss. The experiments of drug-carrying skin puncture mice showed that the stained area of tacrolimus was brighter and more uniformly distributed, the stained area of microtextured microneedles was larger than that of ordinary microneedles by 70.52%, the drug-carrying area was larger than the average area of ordinary microneedles by 105.09%, and the drug-carrying effect of microtextured microneedles with a horizontal inclination angle of 30° was more effective.https://doi.org/10.1038/s41598-024-83094-zMicrotextureMicroneedle arrayFinite element analysisMonte Carlo methodFocused ion beam
spellingShingle Yan Zhang
Zhaoqiang Chen
Wendong Wu
Chonghai Xu
Focused ion beam (FIB) prepared microtextured microneedle array capable of delivering drugs through punctured skin
Scientific Reports
Microtexture
Microneedle array
Finite element analysis
Monte Carlo method
Focused ion beam
title Focused ion beam (FIB) prepared microtextured microneedle array capable of delivering drugs through punctured skin
title_full Focused ion beam (FIB) prepared microtextured microneedle array capable of delivering drugs through punctured skin
title_fullStr Focused ion beam (FIB) prepared microtextured microneedle array capable of delivering drugs through punctured skin
title_full_unstemmed Focused ion beam (FIB) prepared microtextured microneedle array capable of delivering drugs through punctured skin
title_short Focused ion beam (FIB) prepared microtextured microneedle array capable of delivering drugs through punctured skin
title_sort focused ion beam fib prepared microtextured microneedle array capable of delivering drugs through punctured skin
topic Microtexture
Microneedle array
Finite element analysis
Monte Carlo method
Focused ion beam
url https://doi.org/10.1038/s41598-024-83094-z
work_keys_str_mv AT yanzhang focusedionbeamfibpreparedmicrotexturedmicroneedlearraycapableofdeliveringdrugsthroughpuncturedskin
AT zhaoqiangchen focusedionbeamfibpreparedmicrotexturedmicroneedlearraycapableofdeliveringdrugsthroughpuncturedskin
AT wendongwu focusedionbeamfibpreparedmicrotexturedmicroneedlearraycapableofdeliveringdrugsthroughpuncturedskin
AT chonghaixu focusedionbeamfibpreparedmicrotexturedmicroneedlearraycapableofdeliveringdrugsthroughpuncturedskin