Research on Equivalent Circuit Model of HVDC Valve and Calculation of Thyristor Junction Temperature

For the difference of thyristor junction temperature at all levels in the transducer valve assembly in the series water circuit, an equivalent model of thyristor junction temperature calculation for the valve assembly is established, and PLECS simulation software is used to simulate and solve the ju...

Full description

Saved in:
Bibliographic Details
Main Authors: Wei Yao, Yang Liu, Lei Guo, Guojun Ding, Chaofeng Zhang, Sen Wang
Format: Article
Language:English
Published: Wiley 2024-01-01
Series:Active and Passive Electronic Components
Online Access:http://dx.doi.org/10.1155/2024/6671153
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:For the difference of thyristor junction temperature at all levels in the transducer valve assembly in the series water circuit, an equivalent model of thyristor junction temperature calculation for the valve assembly is established, and PLECS simulation software is used to simulate and solve the junction temperature at all levels of the thyristor and check the junction temperature of the thyristor from the highest temperature of the measured radiator surface, and the results of the junction temperature checking show that the equivalent model of thyristor junction temperature calculation for the valve assembly has a high accuracy.
ISSN:1563-5031