Comparison of 70% alcohol, Deconex, H2O2 and UV Light for disinfection of surfaces and equipment’s infertility Research laboratory of Yazd

Background: Decontamination is a process that infectious organisms are removed by physical and chemical methods. The advantages and disadvantages of each of these values can lead to a clear viewpoint of an appropriate sterilization process. The aim of this study was to investigate the effectiveness...

Full description

Saved in:
Bibliographic Details
Main Authors: F Anbari, A Nabi, M Khalili
Format: Article
Language:English
Published: Shahid Sadoughi University of Medical Science 2014-10-01
Series:طب کار
Subjects:
Online Access:http://tkj.ssu.ac.ir/article-1-358-en.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849225165688274944
author F Anbari
A Nabi
M Khalili
author_facet F Anbari
A Nabi
M Khalili
author_sort F Anbari
collection DOAJ
description Background: Decontamination is a process that infectious organisms are removed by physical and chemical methods. The advantages and disadvantages of each of these values can lead to a clear viewpoint of an appropriate sterilization process. The aim of this study was to investigate the effectiveness of 70% alcohol, Deconex (SOLARSEPT) and H2O2, also the additive effect of supplemental UV light on decontamination of laboratory items. Methods: The rates of contaminations of laboratory equipment’s and surface areas were assessed before and after exposure with mentioned chemicals and in the final stage by UV light. Overall the 12 laboratory equipment and the 7 office instrument were evaluated. The UV light was used for 40 min from distance of 2.5 meter. Then, all points were sampled after decontamination and the microbial plates were incubated for microbial colony counts after 48h. Results: The number of colonies before disinfection stage was 26.43 colonies per unit (cfu) in administrative and 15.17 in laboratory equipment. After using UV, H2O2, ethanol and Deconex, the numbers of colonies were reduced to 2.57, 0.4, 1.29 and 0.71, respectively (p <0.05). Simultaneous use of H2O2 and Deconex with UV light reduced the numbers of colony to 0.14 and 0.17. In the administrative equipment’s, the number of colonies after H2O2, ethanol, deconex and UV light were 0, 1.67, 1.25 and 0.83, respectively. Also, combination of UV with deconex and H2O2 reduced the colony formation to zero. Conclusion: H2O2 was effective on reducing the number of colonies. Due to low toxicity, it is recommended to be used in infertility lab. We must make sure that application of disinfection chemicals will not interfere with the laboratory experiments and limits the threat to health of staff.
format Article
id doaj-art-320ad65088dc4152bd683effd168d4f8
institution Kabale University
issn 2251-7189
2251-8274
language English
publishDate 2014-10-01
publisher Shahid Sadoughi University of Medical Science
record_format Article
series طب کار
spelling doaj-art-320ad65088dc4152bd683effd168d4f82025-08-25T05:53:25ZengShahid Sadoughi University of Medical Scienceطب کار2251-71892251-82742014-10-01631219Comparison of 70% alcohol, Deconex, H2O2 and UV Light for disinfection of surfaces and equipment’s infertility Research laboratory of YazdF Anbari0A Nabi1M Khalili2 Research and Clinical Center for Infertility, Shahid Sadoughi University of Medical Sciences, Yazd, Iran. Research and Clinical Center for Infertility, Shahid Sadoughi University of Medical Sciences, Yazd, Iran Research and Clinical Center for Infertility, Shahid Sadoughi University of Medical Sciences, Yazd, Iran Background: Decontamination is a process that infectious organisms are removed by physical and chemical methods. The advantages and disadvantages of each of these values can lead to a clear viewpoint of an appropriate sterilization process. The aim of this study was to investigate the effectiveness of 70% alcohol, Deconex (SOLARSEPT) and H2O2, also the additive effect of supplemental UV light on decontamination of laboratory items. Methods: The rates of contaminations of laboratory equipment’s and surface areas were assessed before and after exposure with mentioned chemicals and in the final stage by UV light. Overall the 12 laboratory equipment and the 7 office instrument were evaluated. The UV light was used for 40 min from distance of 2.5 meter. Then, all points were sampled after decontamination and the microbial plates were incubated for microbial colony counts after 48h. Results: The number of colonies before disinfection stage was 26.43 colonies per unit (cfu) in administrative and 15.17 in laboratory equipment. After using UV, H2O2, ethanol and Deconex, the numbers of colonies were reduced to 2.57, 0.4, 1.29 and 0.71, respectively (p <0.05). Simultaneous use of H2O2 and Deconex with UV light reduced the numbers of colony to 0.14 and 0.17. In the administrative equipment’s, the number of colonies after H2O2, ethanol, deconex and UV light were 0, 1.67, 1.25 and 0.83, respectively. Also, combination of UV with deconex and H2O2 reduced the colony formation to zero. Conclusion: H2O2 was effective on reducing the number of colonies. Due to low toxicity, it is recommended to be used in infertility lab. We must make sure that application of disinfection chemicals will not interfere with the laboratory experiments and limits the threat to health of staff.http://tkj.ssu.ac.ir/article-1-358-en.pdfh2o2ethanol 70%deconexuv light
spellingShingle F Anbari
A Nabi
M Khalili
Comparison of 70% alcohol, Deconex, H2O2 and UV Light for disinfection of surfaces and equipment’s infertility Research laboratory of Yazd
طب کار
h2o2
ethanol 70%
deconex
uv light
title Comparison of 70% alcohol, Deconex, H2O2 and UV Light for disinfection of surfaces and equipment’s infertility Research laboratory of Yazd
title_full Comparison of 70% alcohol, Deconex, H2O2 and UV Light for disinfection of surfaces and equipment’s infertility Research laboratory of Yazd
title_fullStr Comparison of 70% alcohol, Deconex, H2O2 and UV Light for disinfection of surfaces and equipment’s infertility Research laboratory of Yazd
title_full_unstemmed Comparison of 70% alcohol, Deconex, H2O2 and UV Light for disinfection of surfaces and equipment’s infertility Research laboratory of Yazd
title_short Comparison of 70% alcohol, Deconex, H2O2 and UV Light for disinfection of surfaces and equipment’s infertility Research laboratory of Yazd
title_sort comparison of 70 alcohol deconex h2o2 and uv light for disinfection of surfaces and equipment s infertility research laboratory of yazd
topic h2o2
ethanol 70%
deconex
uv light
url http://tkj.ssu.ac.ir/article-1-358-en.pdf
work_keys_str_mv AT fanbari comparisonof70alcoholdeconexh2o2anduvlightfordisinfectionofsurfacesandequipmentsinfertilityresearchlaboratoryofyazd
AT anabi comparisonof70alcoholdeconexh2o2anduvlightfordisinfectionofsurfacesandequipmentsinfertilityresearchlaboratoryofyazd
AT mkhalili comparisonof70alcoholdeconexh2o2anduvlightfordisinfectionofsurfacesandequipmentsinfertilityresearchlaboratoryofyazd