Performance Analysis and Application Research of Low-Pressure Cylinder Zero Output Technology on 320 MW Unit

Using low-pressure cylinder zero output technology can effectively improve the heating capacity and peak regulation capacity of the generation unit. In this paper, taking a 320 MW heating unit for example, firstly, Ebsilon software is used to calculate and analyze the heating performance of low-pres...

Full description

Saved in:
Bibliographic Details
Main Authors: Shuangbai LIU, Jing ZHANG, Xin WU, Yuou HU
Format: Article
Language:zho
Published: State Grid Energy Research Institute 2021-05-01
Series:Zhongguo dianli
Subjects:
Online Access:https://www.electricpower.com.cn/CN/10.11930/j.issn.1004-9649.202101053
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850030084719640576
author Shuangbai LIU
Jing ZHANG
Xin WU
Yuou HU
author_facet Shuangbai LIU
Jing ZHANG
Xin WU
Yuou HU
author_sort Shuangbai LIU
collection DOAJ
description Using low-pressure cylinder zero output technology can effectively improve the heating capacity and peak regulation capacity of the generation unit. In this paper, taking a 320 MW heating unit for example, firstly, Ebsilon software is used to calculate and analyze the heating performance of low-pressure cylinder zero output. The results show that the application of low-pressure cylinder zero output technology increased the maximum heating extraction steam flow of the unit by 97%, and reduced the net coal consumption by 61 g/(kW·h) at 250 MW heating load. Then, the test study on the heating capacity of low-pressure cylinder zero output mode of the unit was carried out. Field measurements show that the maximum heating load of the unit can reach as much as 476 MW, while the minimum electric load can be reduced to 79.5 MW. At last, based on the operation data of the heating season of previous year, the economic performance of low-pressure cylinder zero output mode is analyzed. The results show that using this heating mode can save 5581 t of standard coal equivalent.
format Article
id doaj-art-31d421cd093f45dfb4231209af1d19dd
institution DOAJ
issn 1004-9649
language zho
publishDate 2021-05-01
publisher State Grid Energy Research Institute
record_format Article
series Zhongguo dianli
spelling doaj-art-31d421cd093f45dfb4231209af1d19dd2025-08-20T02:59:19ZzhoState Grid Energy Research InstituteZhongguo dianli1004-96492021-05-0154521322010.11930/j.issn.1004-9649.202101053zgdl-54-4-liushuangbaiPerformance Analysis and Application Research of Low-Pressure Cylinder Zero Output Technology on 320 MW UnitShuangbai LIU0Jing ZHANG1Xin WU2Yuou HU3State Grid Jibei Electric Power Research Institute (North China Electric Power Research Institute Co., Ltd.), Beijing 100045North China Branch of State Grid Corporation of China, Beijing 100053State Grid Jibei Electric Power Research Institute (North China Electric Power Research Institute Co., Ltd.), Beijing 100045North China Branch of State Grid Corporation of China, Beijing 100053Using low-pressure cylinder zero output technology can effectively improve the heating capacity and peak regulation capacity of the generation unit. In this paper, taking a 320 MW heating unit for example, firstly, Ebsilon software is used to calculate and analyze the heating performance of low-pressure cylinder zero output. The results show that the application of low-pressure cylinder zero output technology increased the maximum heating extraction steam flow of the unit by 97%, and reduced the net coal consumption by 61 g/(kW·h) at 250 MW heating load. Then, the test study on the heating capacity of low-pressure cylinder zero output mode of the unit was carried out. Field measurements show that the maximum heating load of the unit can reach as much as 476 MW, while the minimum electric load can be reduced to 79.5 MW. At last, based on the operation data of the heating season of previous year, the economic performance of low-pressure cylinder zero output mode is analyzed. The results show that using this heating mode can save 5581 t of standard coal equivalent.https://www.electricpower.com.cn/CN/10.11930/j.issn.1004-9649.202101053low-pressure cylinder zero outputheat-electricity cogenerationheating loadenergy saving
spellingShingle Shuangbai LIU
Jing ZHANG
Xin WU
Yuou HU
Performance Analysis and Application Research of Low-Pressure Cylinder Zero Output Technology on 320 MW Unit
Zhongguo dianli
low-pressure cylinder zero output
heat-electricity cogeneration
heating load
energy saving
title Performance Analysis and Application Research of Low-Pressure Cylinder Zero Output Technology on 320 MW Unit
title_full Performance Analysis and Application Research of Low-Pressure Cylinder Zero Output Technology on 320 MW Unit
title_fullStr Performance Analysis and Application Research of Low-Pressure Cylinder Zero Output Technology on 320 MW Unit
title_full_unstemmed Performance Analysis and Application Research of Low-Pressure Cylinder Zero Output Technology on 320 MW Unit
title_short Performance Analysis and Application Research of Low-Pressure Cylinder Zero Output Technology on 320 MW Unit
title_sort performance analysis and application research of low pressure cylinder zero output technology on 320 mw unit
topic low-pressure cylinder zero output
heat-electricity cogeneration
heating load
energy saving
url https://www.electricpower.com.cn/CN/10.11930/j.issn.1004-9649.202101053
work_keys_str_mv AT shuangbailiu performanceanalysisandapplicationresearchoflowpressurecylinderzerooutputtechnologyon320mwunit
AT jingzhang performanceanalysisandapplicationresearchoflowpressurecylinderzerooutputtechnologyon320mwunit
AT xinwu performanceanalysisandapplicationresearchoflowpressurecylinderzerooutputtechnologyon320mwunit
AT yuouhu performanceanalysisandapplicationresearchoflowpressurecylinderzerooutputtechnologyon320mwunit