Volatile Organic Compounds and Carbonyls Pollution in Mexico City and an Urban Industrialized Area of Central Mexico
Abstract A total of 130 volatile organic compounds (VOCs) and 14 carbonyls were measured at the Jasso (JAS) and Tepeji (TEP) sites during the warm-dry season of 2006 in Tula, Hidalgo, Mexico, a highly industrialized area with more than 120 industries. These data were compared with those obtained in...
Saved in:
Main Authors: | , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Springer
2022-04-01
|
Series: | Aerosol and Air Quality Research |
Subjects: | |
Online Access: | https://doi.org/10.4209/aaqr.210386 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1825197585109876736 |
---|---|
author | Elizabeth Vega Omar Ramírez Gabriela Sánchez-Reyna Judith C. Chow John G. Watson Diego López-Veneroni Monica Jaimes-Palomera |
author_facet | Elizabeth Vega Omar Ramírez Gabriela Sánchez-Reyna Judith C. Chow John G. Watson Diego López-Veneroni Monica Jaimes-Palomera |
author_sort | Elizabeth Vega |
collection | DOAJ |
description | Abstract A total of 130 volatile organic compounds (VOCs) and 14 carbonyls were measured at the Jasso (JAS) and Tepeji (TEP) sites during the warm-dry season of 2006 in Tula, Hidalgo, Mexico, a highly industrialized area with more than 120 industries. These data were compared with those obtained in Mexico City during 2006 and 2012 at an urban center (Merced, MER) site and a southwest residential (Pedregal, PED) site. Average VOC concentrations in Tula were dominated by alkanes (40.8–42.2% of the total VOCs), followed by alkenes (10.3–11.9%), oxygenated compounds (10.0–11.5%), aromatics (7.3–12.5%), halogenated species (7.0–9.3%), and acetylene (1.6–2.4%), denotating a highly reactive atmosphere. High concentrations of propane and nButane are associated with leakage, handling, and distribution of liquified petroleum gas (LPG). The highest concentrations were found for formaldehyde at 87.2 µg m−3, followed by acetaldehyde (52.1 µg m−3) and acetone (49.7 µg m−3), accounting for 96% of the total carbonyls in Tula. VOC emission sources associated with industrial processes (such as oil refineries, power plants, plastic manufacturing, asphalt production, and solvent usage), vehicular exhaust, evaporated gasoline, LPG, food cooking, and biogenic emissions were identified using the Positive Matrix Factorization (PMF) solution to the chemical mass balance (CMB) model. A health risk assessment for toxic species such as benzene, toluene, ethyl benzene and xylenes (BTEX), found a decreasing trend from 2006 to 2012. Lifetime cancer risks (LCR) from benzene ranged from 1.5 × 10−5 to 6.1 × 10−5 in 2006 and from 8.8 × 10−6 to 2.2 × 10−5 in 2012 for the urban MER site. This database establishes baselines for evaluating the effectiveness of emission reduction strategies. |
format | Article |
id | doaj-art-3174890ff03d41e39f2d53a977d0fdb0 |
institution | Kabale University |
issn | 1680-8584 2071-1409 |
language | English |
publishDate | 2022-04-01 |
publisher | Springer |
record_format | Article |
series | Aerosol and Air Quality Research |
spelling | doaj-art-3174890ff03d41e39f2d53a977d0fdb02025-02-09T12:17:25ZengSpringerAerosol and Air Quality Research1680-85842071-14092022-04-0122612210.4209/aaqr.210386Volatile Organic Compounds and Carbonyls Pollution in Mexico City and an Urban Industrialized Area of Central MexicoElizabeth Vega0Omar Ramírez1Gabriela Sánchez-Reyna2Judith C. Chow3John G. Watson4Diego López-Veneroni5Monica Jaimes-Palomera6Instituto de Ciencias de la Atmósfera y Cambio Climático, Sección de Contaminación Ambiental, Universidad Nacional Autónoma de México, Circuito Exterior, Ciudad UniversitariaFaculty of Engineering, Environmental Engineering, Universidad Militar Nueva GranadaInstituto Mexicano del PetróleoDivision of Atmospheric Sciences, Desert Research InstituteDivision of Atmospheric Sciences, Desert Research InstituteIndependent ResearcherSecretaria del Medio AmbienteAbstract A total of 130 volatile organic compounds (VOCs) and 14 carbonyls were measured at the Jasso (JAS) and Tepeji (TEP) sites during the warm-dry season of 2006 in Tula, Hidalgo, Mexico, a highly industrialized area with more than 120 industries. These data were compared with those obtained in Mexico City during 2006 and 2012 at an urban center (Merced, MER) site and a southwest residential (Pedregal, PED) site. Average VOC concentrations in Tula were dominated by alkanes (40.8–42.2% of the total VOCs), followed by alkenes (10.3–11.9%), oxygenated compounds (10.0–11.5%), aromatics (7.3–12.5%), halogenated species (7.0–9.3%), and acetylene (1.6–2.4%), denotating a highly reactive atmosphere. High concentrations of propane and nButane are associated with leakage, handling, and distribution of liquified petroleum gas (LPG). The highest concentrations were found for formaldehyde at 87.2 µg m−3, followed by acetaldehyde (52.1 µg m−3) and acetone (49.7 µg m−3), accounting for 96% of the total carbonyls in Tula. VOC emission sources associated with industrial processes (such as oil refineries, power plants, plastic manufacturing, asphalt production, and solvent usage), vehicular exhaust, evaporated gasoline, LPG, food cooking, and biogenic emissions were identified using the Positive Matrix Factorization (PMF) solution to the chemical mass balance (CMB) model. A health risk assessment for toxic species such as benzene, toluene, ethyl benzene and xylenes (BTEX), found a decreasing trend from 2006 to 2012. Lifetime cancer risks (LCR) from benzene ranged from 1.5 × 10−5 to 6.1 × 10−5 in 2006 and from 8.8 × 10−6 to 2.2 × 10−5 in 2012 for the urban MER site. This database establishes baselines for evaluating the effectiveness of emission reduction strategies.https://doi.org/10.4209/aaqr.210386Industrial pollutionVOCsRisk assessmentSources of VOCsBTEX |
spellingShingle | Elizabeth Vega Omar Ramírez Gabriela Sánchez-Reyna Judith C. Chow John G. Watson Diego López-Veneroni Monica Jaimes-Palomera Volatile Organic Compounds and Carbonyls Pollution in Mexico City and an Urban Industrialized Area of Central Mexico Aerosol and Air Quality Research Industrial pollution VOCs Risk assessment Sources of VOCs BTEX |
title | Volatile Organic Compounds and Carbonyls Pollution in Mexico City and an Urban Industrialized Area of Central Mexico |
title_full | Volatile Organic Compounds and Carbonyls Pollution in Mexico City and an Urban Industrialized Area of Central Mexico |
title_fullStr | Volatile Organic Compounds and Carbonyls Pollution in Mexico City and an Urban Industrialized Area of Central Mexico |
title_full_unstemmed | Volatile Organic Compounds and Carbonyls Pollution in Mexico City and an Urban Industrialized Area of Central Mexico |
title_short | Volatile Organic Compounds and Carbonyls Pollution in Mexico City and an Urban Industrialized Area of Central Mexico |
title_sort | volatile organic compounds and carbonyls pollution in mexico city and an urban industrialized area of central mexico |
topic | Industrial pollution VOCs Risk assessment Sources of VOCs BTEX |
url | https://doi.org/10.4209/aaqr.210386 |
work_keys_str_mv | AT elizabethvega volatileorganiccompoundsandcarbonylspollutioninmexicocityandanurbanindustrializedareaofcentralmexico AT omarramirez volatileorganiccompoundsandcarbonylspollutioninmexicocityandanurbanindustrializedareaofcentralmexico AT gabrielasanchezreyna volatileorganiccompoundsandcarbonylspollutioninmexicocityandanurbanindustrializedareaofcentralmexico AT judithcchow volatileorganiccompoundsandcarbonylspollutioninmexicocityandanurbanindustrializedareaofcentralmexico AT johngwatson volatileorganiccompoundsandcarbonylspollutioninmexicocityandanurbanindustrializedareaofcentralmexico AT diegolopezveneroni volatileorganiccompoundsandcarbonylspollutioninmexicocityandanurbanindustrializedareaofcentralmexico AT monicajaimespalomera volatileorganiccompoundsandcarbonylspollutioninmexicocityandanurbanindustrializedareaofcentralmexico |