Design of hollow tapered PMMA polymeric microneedles for enhanced structural stability and drug delivery efficiency

Microneedles have emerged as a promising alternative to conventional, or so-called hypodermic, needles for transdermal drug delivery. A meticulous design of microneedle geometry is crucial for balancing mechanical stability and fluid flow of drugs through these microneedles. This research paper anal...

Full description

Saved in:
Bibliographic Details
Main Authors: Aswani Kumar Gera, Rajesh Kumar Burra
Format: Article
Language:English
Published: AIP Publishing LLC 2025-01-01
Series:AIP Advances
Online Access:http://dx.doi.org/10.1063/5.0244005
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832542774870671360
author Aswani Kumar Gera
Rajesh Kumar Burra
author_facet Aswani Kumar Gera
Rajesh Kumar Burra
author_sort Aswani Kumar Gera
collection DOAJ
description Microneedles have emerged as a promising alternative to conventional, or so-called hypodermic, needles for transdermal drug delivery. A meticulous design of microneedle geometry is crucial for balancing mechanical stability and fluid flow of drugs through these microneedles. This research paper analyzes the mechanical performance and fluid flow behavior of hollow cylindrical tapered shaped microneedles with polymethyl methacrylate, a biocompatible polymer, as material, considering its mechanical properties and also the material being widely used in biomedical applications. The finite element analysis tool is used to enhance the microneedle design by varying the outer base radius and tip radii to mitigate the von Mises stress that is exhibited during axial load and bending load conditions. In addition, microfluidic analysis is to assess the fluid flow behavior through the hollow microneedles, measuring the flow rates of fluids (water, glucose, and insulin).Simulated results reveal that an axial stress of 3.26 × 106 N/m2 and bending stress of 2.31 × 107 N/m2 were reported, which are below the yield strength of the material and satisfy the criteria for successful microneedle penetration. Flow rate analysis of water reports that 834.42 μl/min and 5396.94 μl/min and for glucose as 412 μl/min and 3648 μl/min, and that of insulin as 834 μl/min and 5244 μl/min for applied inlet pressure of 10 and 100 kPa, respectively. The flow rates reveal that water and insulin exhibit nearly identical flow rates, indicating that the proposed microneedles are capable of efficiently delivering viscous fluids.
format Article
id doaj-art-3130c3bc8f184d4ebf7185e25d549fde
institution Kabale University
issn 2158-3226
language English
publishDate 2025-01-01
publisher AIP Publishing LLC
record_format Article
series AIP Advances
spelling doaj-art-3130c3bc8f184d4ebf7185e25d549fde2025-02-03T16:40:42ZengAIP Publishing LLCAIP Advances2158-32262025-01-01151015034015034-1810.1063/5.0244005Design of hollow tapered PMMA polymeric microneedles for enhanced structural stability and drug delivery efficiencyAswani Kumar GeraRajesh Kumar BurraMicroneedles have emerged as a promising alternative to conventional, or so-called hypodermic, needles for transdermal drug delivery. A meticulous design of microneedle geometry is crucial for balancing mechanical stability and fluid flow of drugs through these microneedles. This research paper analyzes the mechanical performance and fluid flow behavior of hollow cylindrical tapered shaped microneedles with polymethyl methacrylate, a biocompatible polymer, as material, considering its mechanical properties and also the material being widely used in biomedical applications. The finite element analysis tool is used to enhance the microneedle design by varying the outer base radius and tip radii to mitigate the von Mises stress that is exhibited during axial load and bending load conditions. In addition, microfluidic analysis is to assess the fluid flow behavior through the hollow microneedles, measuring the flow rates of fluids (water, glucose, and insulin).Simulated results reveal that an axial stress of 3.26 × 106 N/m2 and bending stress of 2.31 × 107 N/m2 were reported, which are below the yield strength of the material and satisfy the criteria for successful microneedle penetration. Flow rate analysis of water reports that 834.42 μl/min and 5396.94 μl/min and for glucose as 412 μl/min and 3648 μl/min, and that of insulin as 834 μl/min and 5244 μl/min for applied inlet pressure of 10 and 100 kPa, respectively. The flow rates reveal that water and insulin exhibit nearly identical flow rates, indicating that the proposed microneedles are capable of efficiently delivering viscous fluids.http://dx.doi.org/10.1063/5.0244005
spellingShingle Aswani Kumar Gera
Rajesh Kumar Burra
Design of hollow tapered PMMA polymeric microneedles for enhanced structural stability and drug delivery efficiency
AIP Advances
title Design of hollow tapered PMMA polymeric microneedles for enhanced structural stability and drug delivery efficiency
title_full Design of hollow tapered PMMA polymeric microneedles for enhanced structural stability and drug delivery efficiency
title_fullStr Design of hollow tapered PMMA polymeric microneedles for enhanced structural stability and drug delivery efficiency
title_full_unstemmed Design of hollow tapered PMMA polymeric microneedles for enhanced structural stability and drug delivery efficiency
title_short Design of hollow tapered PMMA polymeric microneedles for enhanced structural stability and drug delivery efficiency
title_sort design of hollow tapered pmma polymeric microneedles for enhanced structural stability and drug delivery efficiency
url http://dx.doi.org/10.1063/5.0244005
work_keys_str_mv AT aswanikumargera designofhollowtaperedpmmapolymericmicroneedlesforenhancedstructuralstabilityanddrugdeliveryefficiency
AT rajeshkumarburra designofhollowtaperedpmmapolymericmicroneedlesforenhancedstructuralstabilityanddrugdeliveryefficiency