Delivery of Radioiodine Ablation in a Patient with End-Stage Renal Disease

This case presents a pragmatic approach to the management of a radioiodine remnant ablation patient on hemodialysis which required no pretherapeutic dosimetric measurements. Pretreatment radiation dose modeling was performed using literature values for radioiodine hemodialysis extraction efficacies...

Full description

Saved in:
Bibliographic Details
Main Authors: Andrew T. Bussey, Aung Tin, Neil Hoye, Mark Richardson
Format: Article
Language:English
Published: Thieme Medical and Scientific Publishers Pvt. Ltd. 2022-12-01
Series:World Journal of Nuclear Medicine
Subjects:
Online Access:http://www.thieme-connect.de/DOI/DOI?10.1055/s-0042-1750405
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849700037586583552
author Andrew T. Bussey
Aung Tin
Neil Hoye
Mark Richardson
author_facet Andrew T. Bussey
Aung Tin
Neil Hoye
Mark Richardson
author_sort Andrew T. Bussey
collection DOAJ
description This case presents a pragmatic approach to the management of a radioiodine remnant ablation patient on hemodialysis which required no pretherapeutic dosimetric measurements. Pretreatment radiation dose modeling was performed using literature values for radioiodine hemodialysis extraction efficacies to determine a safe treatment regimen including adjustment of the administered activity and hemodialysis frequency. The pretreatment modeling was subsequently verified using external and blood radiation monitoring during treatment.
format Article
id doaj-art-30fc736713f1489f9ab954d6b2ba64ab
institution DOAJ
issn 1450-1147
1607-3312
language English
publishDate 2022-12-01
publisher Thieme Medical and Scientific Publishers Pvt. Ltd.
record_format Article
series World Journal of Nuclear Medicine
spelling doaj-art-30fc736713f1489f9ab954d6b2ba64ab2025-08-20T03:18:24ZengThieme Medical and Scientific Publishers Pvt. Ltd.World Journal of Nuclear Medicine1450-11471607-33122022-12-01210432032410.1055/s-0042-1750405Delivery of Radioiodine Ablation in a Patient with End-Stage Renal DiseaseAndrew T. Bussey0Aung Tin1Neil Hoye2Mark Richardson3Department of Nuclear Medicine, South Tees Hospitals NHS Foundation Trust, Middlesbrough, United KingdomThe James Cook Cancer Institute, South Tees Hospitals NHS Foundation Trust, Middlesbrough, United KingdomDepartment of Renal Medicine, South Tees Hospitals NHS Foundation Trust, Middlesbrough, United KingdomDepartment of Nuclear Medicine, South Tees Hospitals NHS Foundation Trust, Middlesbrough, United KingdomThis case presents a pragmatic approach to the management of a radioiodine remnant ablation patient on hemodialysis which required no pretherapeutic dosimetric measurements. Pretreatment radiation dose modeling was performed using literature values for radioiodine hemodialysis extraction efficacies to determine a safe treatment regimen including adjustment of the administered activity and hemodialysis frequency. The pretreatment modeling was subsequently verified using external and blood radiation monitoring during treatment.http://www.thieme-connect.de/DOI/DOI?10.1055/s-0042-1750405thyroid carcinomai-131hemodialysisend-stage renal disease
spellingShingle Andrew T. Bussey
Aung Tin
Neil Hoye
Mark Richardson
Delivery of Radioiodine Ablation in a Patient with End-Stage Renal Disease
World Journal of Nuclear Medicine
thyroid carcinoma
i-131
hemodialysis
end-stage renal disease
title Delivery of Radioiodine Ablation in a Patient with End-Stage Renal Disease
title_full Delivery of Radioiodine Ablation in a Patient with End-Stage Renal Disease
title_fullStr Delivery of Radioiodine Ablation in a Patient with End-Stage Renal Disease
title_full_unstemmed Delivery of Radioiodine Ablation in a Patient with End-Stage Renal Disease
title_short Delivery of Radioiodine Ablation in a Patient with End-Stage Renal Disease
title_sort delivery of radioiodine ablation in a patient with end stage renal disease
topic thyroid carcinoma
i-131
hemodialysis
end-stage renal disease
url http://www.thieme-connect.de/DOI/DOI?10.1055/s-0042-1750405
work_keys_str_mv AT andrewtbussey deliveryofradioiodineablationinapatientwithendstagerenaldisease
AT aungtin deliveryofradioiodineablationinapatientwithendstagerenaldisease
AT neilhoye deliveryofradioiodineablationinapatientwithendstagerenaldisease
AT markrichardson deliveryofradioiodineablationinapatientwithendstagerenaldisease