Low Concentration Hydrogen Combustion and Its Influence Analysis outside PCS Internal Heat Exchanger

In severe accidents, the zirconium water reaction produces a large amount of hydrogen and inevitably releases a large amount of heat. Passive containment cooling system (PCS) internal heat exchanger is a nuclear safety class equipment and an important component of PCS, which could export heat from t...

Full description

Saved in:
Bibliographic Details
Main Author: ZHANG Dong1, DING Ming2, SHAO Xiaozhou1, HAO Xiaohua1, LI Long1
Format: Article
Language:English
Published: Editorial Board of Atomic Energy Science and Technology 2024-07-01
Series:Yuanzineng kexue jishu
Subjects:
Online Access:https://yznkxjs.xml-journal.net/article/doi/10.7538/yzk.2023.youxian.0516
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850285051440267264
author ZHANG Dong1, DING Ming2, SHAO Xiaozhou1, HAO Xiaohua1, LI Long1
author_facet ZHANG Dong1, DING Ming2, SHAO Xiaozhou1, HAO Xiaohua1, LI Long1
author_sort ZHANG Dong1, DING Ming2, SHAO Xiaozhou1, HAO Xiaohua1, LI Long1
collection DOAJ
description In severe accidents, the zirconium water reaction produces a large amount of hydrogen and inevitably releases a large amount of heat. Passive containment cooling system (PCS) internal heat exchanger is a nuclear safety class equipment and an important component of PCS, which could export heat from the containment. Vapor condenses near PCS internal heat exchangers when heat is removed in response to severe incidents. This process leads to an increase in the concentration of hydrogen and air, which increases the possibility of hydrogen combustion near the internal heat exchanger of PCS. Therefore, the commercial fluid calculation software ANSYS was used to conduct hydrogen combustion outside PCS internal heat exchanger and its influence analysis. The hydrogen combustion model was verified by experiment data before use. Liu Yinhe’s cylindrical experiment in Xi’an Jiaotong University was choosed to verify the numerical model of hydrogen combustion. The Fluent module in ANSYS was used to simulate the flame propagation velocity and peak combustion pressure under the initial conditions of 10% initial hydrogen concentration, 0.1 MPa initial pressure and 323 K initial temperature. The calculated results are in good agreement with experimental data. Therefore, the hydrogen combustion model selected in this paper can effectively simulate the hydrogen combustion outside PCS internal heat exchanger. The influence of initial hydrogen concentration, convective heat transfer coefficient in heat exchanger tube and tube bundle on thermal characteristics of the heat exchanger was studied by using Fluent module in ANSYS. The initial hydrogen concentration was 8%, 10% and 12%. The range of convective heat transfer coefficient in heat exchange tubes was 200-2 000 W/(m2·K). The tube bundle consisted of three heat exchange tubes. It is found that the most important factors affecting the thermal characteristics of the heat exchanger are the initial hydrogen concentration and the convective heat transfer coefficient in the heat exchange tube. The static structural module of ANSYS was used to simulate the stress of the heat exchanger under external hydrogen combustion condition. Primary membrane stress, local membrane stress and local membrane stress plus bending stress were obtained after stress linearization on the path including upper and lower header shell along wall thickness direction and the maximum stress point along the heat exchanger tube wall thickness direction. Then, compared them with ASME Code Section Ⅲ Division 1, Division NC, and Division 1 Appendices. It is found that the stress level of the evaluation path meets the requirement of the evaluation standard under the condition analyzed in this paper. The research results indicate that under severe accidents, the hydrogen combustion with a concentration of 12% inside the containment does not affect the safe use of the internal heat exchanger of the PCS.
format Article
id doaj-art-304a8e9cda9c45f9bacdd76381eef2fa
institution OA Journals
issn 1000-6931
language English
publishDate 2024-07-01
publisher Editorial Board of Atomic Energy Science and Technology
record_format Article
series Yuanzineng kexue jishu
spelling doaj-art-304a8e9cda9c45f9bacdd76381eef2fa2025-08-20T01:47:25ZengEditorial Board of Atomic Energy Science and TechnologyYuanzineng kexue jishu1000-69312024-07-017581540154710.7538/yzk.2023.youxian.0516Low Concentration Hydrogen Combustion and Its Influence Analysis outside PCS Internal Heat ExchangerZHANG Dong1, DING Ming2, SHAO Xiaozhou1, HAO Xiaohua1, LI Long101. China Institute for Radiation Protection, Taiyuan 030006, China 2. Harbin Engineering University, Harbin 150001, ChinaIn severe accidents, the zirconium water reaction produces a large amount of hydrogen and inevitably releases a large amount of heat. Passive containment cooling system (PCS) internal heat exchanger is a nuclear safety class equipment and an important component of PCS, which could export heat from the containment. Vapor condenses near PCS internal heat exchangers when heat is removed in response to severe incidents. This process leads to an increase in the concentration of hydrogen and air, which increases the possibility of hydrogen combustion near the internal heat exchanger of PCS. Therefore, the commercial fluid calculation software ANSYS was used to conduct hydrogen combustion outside PCS internal heat exchanger and its influence analysis. The hydrogen combustion model was verified by experiment data before use. Liu Yinhe’s cylindrical experiment in Xi’an Jiaotong University was choosed to verify the numerical model of hydrogen combustion. The Fluent module in ANSYS was used to simulate the flame propagation velocity and peak combustion pressure under the initial conditions of 10% initial hydrogen concentration, 0.1 MPa initial pressure and 323 K initial temperature. The calculated results are in good agreement with experimental data. Therefore, the hydrogen combustion model selected in this paper can effectively simulate the hydrogen combustion outside PCS internal heat exchanger. The influence of initial hydrogen concentration, convective heat transfer coefficient in heat exchanger tube and tube bundle on thermal characteristics of the heat exchanger was studied by using Fluent module in ANSYS. The initial hydrogen concentration was 8%, 10% and 12%. The range of convective heat transfer coefficient in heat exchange tubes was 200-2 000 W/(m2·K). The tube bundle consisted of three heat exchange tubes. It is found that the most important factors affecting the thermal characteristics of the heat exchanger are the initial hydrogen concentration and the convective heat transfer coefficient in the heat exchange tube. The static structural module of ANSYS was used to simulate the stress of the heat exchanger under external hydrogen combustion condition. Primary membrane stress, local membrane stress and local membrane stress plus bending stress were obtained after stress linearization on the path including upper and lower header shell along wall thickness direction and the maximum stress point along the heat exchanger tube wall thickness direction. Then, compared them with ASME Code Section Ⅲ Division 1, Division NC, and Division 1 Appendices. It is found that the stress level of the evaluation path meets the requirement of the evaluation standard under the condition analyzed in this paper. The research results indicate that under severe accidents, the hydrogen combustion with a concentration of 12% inside the containment does not affect the safe use of the internal heat exchanger of the PCS. https://yznkxjs.xml-journal.net/article/doi/10.7538/yzk.2023.youxian.0516passive containment cooling systeminternal heat exchangerhydrogen combustionstress analysis
spellingShingle ZHANG Dong1, DING Ming2, SHAO Xiaozhou1, HAO Xiaohua1, LI Long1
Low Concentration Hydrogen Combustion and Its Influence Analysis outside PCS Internal Heat Exchanger
Yuanzineng kexue jishu
passive containment cooling system
internal heat exchanger
hydrogen combustion
stress analysis
title Low Concentration Hydrogen Combustion and Its Influence Analysis outside PCS Internal Heat Exchanger
title_full Low Concentration Hydrogen Combustion and Its Influence Analysis outside PCS Internal Heat Exchanger
title_fullStr Low Concentration Hydrogen Combustion and Its Influence Analysis outside PCS Internal Heat Exchanger
title_full_unstemmed Low Concentration Hydrogen Combustion and Its Influence Analysis outside PCS Internal Heat Exchanger
title_short Low Concentration Hydrogen Combustion and Its Influence Analysis outside PCS Internal Heat Exchanger
title_sort low concentration hydrogen combustion and its influence analysis outside pcs internal heat exchanger
topic passive containment cooling system
internal heat exchanger
hydrogen combustion
stress analysis
url https://yznkxjs.xml-journal.net/article/doi/10.7538/yzk.2023.youxian.0516
work_keys_str_mv AT zhangdong1dingming2shaoxiaozhou1haoxiaohua1lilong1 lowconcentrationhydrogencombustionanditsinfluenceanalysisoutsidepcsinternalheatexchanger